Literature DB >> 22815352

Diagnostic ability of retinal nerve fiber layer thickness measurements and neurologic hemifield test to detect chiasmal compression.

Chan Hee Moon1, Si Hyung Lee, Bum-Tae Kim, Sun Chul Hwang, Young-Hoon Ohn, Tae Kwann Park.   

Abstract

PURPOSE: The purpose of the study was to investigate the diagnostic ability of the neurologic hemifield test (NHT) and retinal nerve fiber layer (RNFL) thickness measurements to detect chiasmal compression.
METHODS: Thirty-seven patients with chiasmal compression, 35 patients with glaucoma, and 30 patients with glaucoma suspect were enrolled. The NHT score was established from a 30-2 visual field pattern deviation probability plot. Each test point value was calculated for a number that was inversely proportional to its pattern deviation probability. The NHT score was the absolute value of the difference in the sum of the point scores for two symmetrical regions of 16 points on either side of the vertical meridian. RNFL thickness was scored from 0 to 10 according to the pattern of RNFL loss and probability of abnormality. Solely present nasal or temporal RNFL defects were scored high, and exclusively appearing superior or nasal RNFL defects were scored low. The differences in the NHT and RNFL scores among the three groups were compared. Diagnostic ability was assessed by receiver operating characteristic (ROC) analysis.
RESULTS: The NHT and RNFL scores were significantly higher in patients with chiasmal compression than in patients with glaucoma and glaucoma suspect. The area under the ROC curve (AROC) was 0.734 of the NHT score and 0.613 of the RNFL score. When AROC was calculated using the NHT and RNFL scores concurrently, AROC was increased to 0.807.
CONCLUSIONS: The NHT score and RNFL score have diagnostic ability to detect chiasmal compression, and simultaneous assessment of NHT and RNFL scores improves the diagnostic power.

Entities:  

Mesh:

Year:  2012        PMID: 22815352     DOI: 10.1167/iovs.12-9905

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  4 in total

1.  Predictive factors of visual function recovery after pituitary adenoma resection: a literature review and Meta-analysis.

Authors:  Min Sun; Zhi-Qiang Zhang; Chi-Yuan Ma; Sui-Hua Chen; Xin-Jian Chen
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

2.  Quantitative Analysis of Macular Retina Using Light Reflection Indices Derived from SD-OCT for Pituitary Adenoma.

Authors:  Min Sun; Hongming Zhang; Xinjian Chen; Qimi Zhang
Journal:  J Ophthalmol       Date:  2020-11-04       Impact factor: 1.909

Review 3.  Optical coherence tomography impacts the evaluation of visual pathway tumors.

Authors:  Ana Banc; Cristina Stan; Ioan Stefan Florian
Journal:  Neurosurg Rev       Date:  2016-07-28       Impact factor: 3.042

4.  Peripapillary Microvascularization Analysis Using Swept-Source Optical Coherence Tomography Angiography in Optic Chiasmal Compression.

Authors:  Inès Ben Ghezala; Déa Haddad; Julie Blanc; Cyril Meillon; Rachid Madkouri; François Borsotti; Alain M Bron; Catherine Creuzot-Garcher
Journal:  J Ophthalmol       Date:  2021-09-04       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.