Literature DB >> 22814040

Clinical validation of an algorithm to correct the error in the keratometric estimation of corneal power in normal eyes.

David P Piñero1, Vicente J Camps, Verónica Mateo, Pedro Ruiz-Fortes.   

Abstract

PURPOSE: To validate clinically in a normal healthy population an algorithm to correct the error in the keratometric estimation of corneal power based on the use of a variable keratometric index of refraction (n(k)).
SETTING: Medimar International Hospital (Oftalmar) and University of Alicante, Alicante, Spain.
DESIGN: Case series.
METHODS: Corneal power was measured with a Scheimpflug photography-based system (Pentacam software version 1.14r01) in healthy eyes with no previous ocular surgery. In all cases, keratometric corneal power was also estimated using an adjusted value of n(k) that is dependent on the anterior corneal radius (r(1c)) as follows: n(kadj) = -0.0064286 r(1c) +1.37688. Agreement between the Gaussian (P(c)(Gauss)) and adjusted keratometric (P(kadj)) corneal power values was evaluated.
RESULTS: The study evaluated 92 eyes (92 patients; age range 15 to 64 years). The mean difference between P(c)(Gauss) and P(kadj) was -0.02 diopter (D) ± 0.22 (SD) (P=.43). A very strong, statistically significant correlation was found between both corneal powers (r = .994, P<.01). The range of agreement between P(c)(Gauss) and P(kadj) was 0.44 D, with limits of agreement of -0.46 and +0.42 D. In addition, a very strong, statistically significant correlation of the difference between P(c)(Gauss) and P(kadj) and the posterior corneal radius was found (r = 0.96, P<.01).
CONCLUSION: The imprecision in the calculation of corneal power using keratometric estimation can be minimized in clinical practice by using a variable keratometric index that depends on the radius of the anterior corneal surface. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22814040     DOI: 10.1016/j.jcrs.2012.03.026

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Validation of corneal topographic and aberrometric measurements obtained by color light-emitting diode reflection topography in healthy eyes.

Authors:  David P Piñero; Ainhoa Molina-Martín; Vicent J Camps; Dolores de Fez; María Teresa Caballero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-03       Impact factor: 3.117

2.  Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position.

Authors:  David P Piñero; Vicente J Camps; MarIa L Ramón; Verónica Mateo; Rafael J Pérez-CambrodI
Journal:  Indian J Ophthalmol       Date:  2015-05       Impact factor: 1.848

3.  Preliminary validation of an optimized algorithm for intraocular lens power calculation in keratoconus.

Authors:  Vicente J Camps; David P Piñero; Esteban Caravaca; Dolores De Fez
Journal:  Indian J Ophthalmol       Date:  2017-08       Impact factor: 1.848

4.  Accuracy of Various Intraocular Lens Power Calculation Formulas in Steep Corneas.

Authors:  Amir Faramarzi; Ali Aghajani; Leila Ghiasian
Journal:  J Ophthalmic Vis Res       Date:  2017 Oct-Dec

5.  Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Keratoconus Eyes after Accelerated Corneal Collagen Crosslinking.

Authors:  David P Piñero; Vicente J Camps; Esteban Caravaca-Arens; Dolores de Fez; Francisco J Blanes-Mompó
Journal:  J Ophthalmol       Date:  2017-10-22       Impact factor: 1.909

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.