Test-retest and intrarater reliability of 2-dimensional ultrasound measurements of distance between rectus abdominis in women.

Patricia Mota1, Augusto Gil Pascoal, Fatima Sancho, Kari Bø.   

Abstract

STUDY
DESIGN: Single-group test-retest reliability study.
OBJECTIVES: To evaluate the test-retest intraobserver reliability of 2-dimensional ultrasound measurement of the distance between the rectus abdominis muscles, the interrectus distance (IRD).
BACKGROUND: Diastasis recti is defined as the separation of the 2 rectus abdominis muscles, with a reported prevalence of between 30% and 70% in women during pregnancy and in the postpartum period. The condition is difficult to measure, and ultrasound imaging has been suggested as a useful method to quantify the diastasis. However, to date, no studies have investigated intratester or intertester reliability of ultrasound to measure the distance between the rectus abdominis muscles during rest and contraction.
METHODS: Ultrasound images from the rectus abdominis were recorded in 24 healthy female volunteers at rest and under 2 conditions of abdominal contraction: abdominal crunch and drawing-in exercises. The probe was positioned at 2 locations: below and above the umbilicus. A blinded investigator measured the IRD offline from 2 different ultrasound images collected on 2 different days (test-retest). Additionally, reanalyses of the same ultrasound images were done on 2 separate occasions (intra-image).
RESULTS: Test-retest measurements of IRD demonstrated good to very good reliability, with intraclass correlation coefficient values between 0.74 and 0.90. The only exception was for IRD measured 2 cm below the umbilicus during the abdominal crunch exercise, which had an intraclass correlation coefficient of 0.50. For intratester reliability of the same images, the intraclass correlation coefficient values were all above 0.90.
CONCLUSION: Ultrasound imaging is a reliable method for measuring the IRD at rest and during abdominal crunch and drawing-in exercises.

Entities:  

Mesh:

Year:  2012        PMID: 22810966     DOI: 10.2519/jospt.2012.4115

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  22 in total

1.  The relative risk to the femoral nerve as a function of patient positioning: potential implications for trigger point dry needling of the iliacus muscle.

Authors:  Andrew M Ball; Michelle Finnegan; Shane Koppenhaver; Will Freres; Jan Dommerholt; Orlando Mayoral Del Moral; Carel Bron; Randy Moore; Erin E Ball; Emily E Gaffney
Journal:  J Man Manip Ther       Date:  2019-02-20

2.  The relationship between diastasis rectus abdominus, pelvic floor trauma and function in primiparous women postpartum.

Authors:  Vered H Eisenberg; Lee Sela; Asaf Weisman; Youssef Masharawi
Journal:  Int Urogynecol J       Date:  2021-01-08       Impact factor: 2.894

3.  Influence of Ultrasound Transducer Tilt in the Cranial and Caudal Directions on Measurements of Inter-Rectus Distance in Parous Women.

Authors:  Nicole F Hills; Nadia Keshwani; Linda McLean
Journal:  Physiother Can       Date:  2018       Impact factor: 1.037

Review 4.  Abdominal wall sonography: a pictorial review.

Authors:  Ferdinando Draghi; Giulio Cocco; Filippo Maria Richelmi; Cosima Schiavone
Journal:  J Ultrasound       Date:  2020-03-03

5.  Inter-Rectus Distance Measurement Using Ultrasound Imaging: Does the Rater Matter?

Authors:  Nadia Keshwani; Nicole Hills; Linda McLean
Journal:  Physiother Can       Date:  2016       Impact factor: 1.037

6.  Effectiveness of Yoga on the Interrectus Distance in Early Postpartum Women: A High-Frequency Ultrasound Study.

Authors:  Qunfeng Li; Siman Lei; Yanhong Liu; Qiongzhu Liu; Ying Chen; Xin Lin; Xinling Zhang
Journal:  Biomed Res Int       Date:  2022-05-20       Impact factor: 3.246

7.  The ultrasound diagnostic criteria for diastasis recti and its correlation with pelvic floor dysfunction in early postpartum women.

Authors:  Enze Qu; Jiawei Wu; Man Zhang; Lili Wu; Ting Zhang; Jing Xu; Xinling Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-02

8.  The Digital Caliper's Interrater Reliability in Measuring the Interrecti Distance and Its Accuracy in Diagnosing the Diastasis of Rectus Abdominis Muscle in the Third Trimester of Pregnancy.

Authors:  Maíra Belo; Adriana Melo; Alexandre Delgado; Adriana Costa; Valéria Anísio; Andrea Lemos
Journal:  J Chiropr Med       Date:  2020-09-04

9.  Reliability of the good balance system(®) for postural sway measurement in poststroke patients.

Authors:  Hyungeun Ha; Kihun Cho; Wanhee Lee
Journal:  J Phys Ther Sci       Date:  2014-02-06

10.  An ultrasound observation study on the levator hiatus with or without diastasis recti abdominis in postpartum women.

Authors:  Peng Tian; Dong Mei Liu; Chao Wang; Yu Gu; Guo Qing Du; Jia Wei Tian
Journal:  Int Urogynecol J       Date:  2021-04-17       Impact factor: 2.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.