Literature DB >> 2280730

Improved quantification of radionuclide uptake using deconvolution and windowed subtraction techniques for scatter compensation in single photon emission computed tomography.

J C Yanch1, M A Flower, S Webb.   

Abstract

A comparison of two methods of scatter compensation in single photon emission computed tomography (SPECT) imaging is made on the basis of improvements in quantification. The methods, scatter-window subtraction and constrained deconvolution of an average point source response function (PSRF), are described; the theoretical basis of each method is also briefly assessed. Improvements in relative quantification offered by each method are measured by examining ratios of counts in hot cylinders to counts in a slightly radioactive background. The cylinder/background concentration ratio was varied by a factor of five; the sizes of the cylinders remained constant. Keeping the diameter of the cylinders constant allowed for an assessment of the effect of concentration differences, without the conflicting effect of variation in the size of the hot source. Results showed that while both scatter-window subtraction and constrained deconvolution offer quantification improvements in the final image, the method of prereconstruction deconvolution of a planar PSRF from each planar projection is substantially more successful than either scatter-window subtraction or other methods of implementing the deconvolution procedure.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2280730     DOI: 10.1118/1.596453

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

Review 1.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

Review 2.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

3.  Cross-camera comparison of SPECT measurements of a 3-D anthropomorphic basal ganglia phantom.

Authors:  Walter Koch; Perry E Radau; Wolfgang Münzing; Klaus Tatsch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01-25       Impact factor: 9.236

4.  Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids.

Authors:  H K Pohjonen; S E Savolainen; P H Nikkinen; V P Poutanen; E T Korppi-Tommola; B K Liewendahl
Journal:  Ann Nucl Med       Date:  1996-11       Impact factor: 2.668

5.  A comparative study of scatter correction methods for scintigraphic images.

Authors:  F Bonnin; I Buvat; H Benali; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-05

Review 6.  Scatter correction in scintigraphy: the state of the art.

Authors:  I Buvat; H Benali; A Todd-Pokropek; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-07

7.  Validation of quantitative brain dopamine D2 receptor imaging with a conventional single-head SPET camera.

Authors:  P Nikkinen; K Liewendahl; S Savolainen; J Launes
Journal:  Eur J Nucl Med       Date:  1993-08

8.  Quantitative single-photon emission tomography for tumour blood flow measurement in bronchial carcinoma.

Authors:  N P Rowell; M A Flower; B Cronin; V R McCready
Journal:  Eur J Nucl Med       Date:  1993-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.