Literature DB >> 22806920

MR imaging of meniscal tears: comparison of intermediate-weighted FRFSE imaging with intermediate-weighted FSE imaging.

Osamu Tokuda1, Yuko Harada, Takaaki Ueda, Etsushi Iida, Gen Shiraishi, Tetsuhisa Motomura, Kouji Fukuda, Naofumi Matsunaga.   

Abstract

PURPOSE: We compared intermediate-weighted fast spin-echo (IW-FSE) images with intermediate-weighted fast-recovery FSE (IW-FRFSE) images in the diagnosis of meniscal tears.
MATERIALS AND METHODS: First, 64 patients were recruited, and the arthroscopic findings (n = 40) and image analysis (n = 19) identified 59 torn menisci with 36 patients. Both the diagnostic performance and image quality in assessing meniscal tears was evaluated for IW-FSE and IW-FRFSE images using a four-point scale. Signal-to-noise ratio (SNR) calculation was performed for both sets of images.
RESULTS: IW-FRFSE image specificity (100 %) for diagnosing the posterior horn of the medial meniscus (MM) tear with reader 1 was significantly higher than that of IW-FSE images (90 %). Mean ratings of the contrast between the lesion and normal signal intensity within the meniscus were significantly higher for the IW-FRFSE image ratings than the IW-FSE images in most meniscal tears. Mean SNRs were significantly higher for IW-FSE images than for IW-FRFSE images (P < 0.05).
CONCLUSIONS: IW-FRFSE imaging can be used as an alternative to the IW-FSE imaging to evaluate meniscal tears.

Entities:  

Mesh:

Year:  2012        PMID: 22806920     DOI: 10.1007/s11604-012-0108-1

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  12 in total

1.  Cervical spine: three-dimensional fast spin-echo MR imaging--improved recovery of longitudinal magnetization with driven equilibrium pulse.

Authors:  E R Melhem; R Itoh; P J Folkers
Journal:  Radiology       Date:  2001-01       Impact factor: 11.105

2.  A fast high-resolution multislice T1-weighted turbo spin-echo (TSE) sequence with a DRIVen equilibrium (DRIVE) pulse for native arthrographic contrast.

Authors:  Klaus Woertler; Ernst J Rummeny; Marcus Settles
Journal:  AJR Am J Roentgenol       Date:  2005-12       Impact factor: 3.959

3.  Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains: application to whole-brain imaging.

Authors:  Jaeseok Park; John P Mugler; Wilhelm Horger; Berthold Kiefer
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

4.  MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse.

Authors:  Rudolf Radlbauer; Friedrich Lomoschitz; Erich Salomonowitz; Knut E Eberhardt; Andreas Stadlbauer
Journal:  Eur J Radiol       Date:  2010-01-21       Impact factor: 3.528

5.  Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences.

Authors:  Jee Young Jung; Young Cheol Yoon; Jong Won Kwon; Jin Hwan Ahn; Bong-Keun Choe
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

6.  MRI of the knee ligaments and menisci: comparison of isotropic-resolution 3D and conventional 2D fast spin-echo sequences at 3 T.

Authors:  Naveen Subhas; Amy Kao; Maxime Freire; Joshua M Polster; Nancy A Obuchowski; Carl S Winalski
Journal:  AJR Am J Roentgenol       Date:  2011-08       Impact factor: 3.959

7.  MR imaging of articular cartilage using driven equilibrium.

Authors:  B A Hargreaves; G E Gold; P K Lang; S M Conolly; J M Pauly; G Bergman; J Vandevenne; D G Nishimura
Journal:  Magn Reson Med       Date:  1999-10       Impact factor: 4.668

8.  Meniscal tears of the knee: accuracy of MR imaging.

Authors:  J V Crues; J Mink; T L Levy; M Lotysch; D W Stoller
Journal:  Radiology       Date:  1987-08       Impact factor: 11.105

9.  MR diagnosis of meniscal tears of the knee: importance of high signal in the meniscus that extends to the surface.

Authors:  A A De Smet; M A Norris; D R Yandow; F A Quintana; B K Graf; J S Keene
Journal:  AJR Am J Roentgenol       Date:  1993-07       Impact factor: 3.959

10.  MRI of the knee at 3T: first clinical results with an isotropic PDfs-weighted 3D-TSE-sequence.

Authors:  Mike Notohamiprodjo; Annie Horng; Matthias F Pietschmann; Peter E Müller; Wilhelm Horger; Jaeseok Park; Alexander Crispin; José Raya Garcia del Olmo; Sabine Weckbach; Karin A Herrmann; Maximilian F Reiser; Christian Glaser
Journal:  Invest Radiol       Date:  2009-09       Impact factor: 6.016

View more
  1 in total

1.  High-Signal Bladder Urine at T1-Weighted MR Imaging Performed 1-7 Days After a Prior Gadolinium-Enhanced MRI: Prevalence and Correlation with Renal Function.

Authors:  Paul Foran; Sinchun Hwang; Yousef Mazaheri; David Panicek
Journal:  BJR Open       Date:  2019-05-29