Literature DB >> 22805295

First experimental-based characterization of oxygen ion beam depth dose distributions at the Heidelberg Ion-Beam Therapy Center.

C Kurz1, A Mairani, K Parodi.   

Abstract

Over the last decades, the application of proton and heavy-ion beams to external beam radiotherapy has rapidly increased. Due to the favourable lateral and depth dose profile, the superposition of narrow ion pencil beams may enable a highly conformal dose delivery to the tumour, with better sparing of the surrounding healthy tissue in comparison to conventional radiation therapy with photons. To fully exploit the promised clinical advantages of ion beams, an accurate planning of the patient treatments is required. The clinical treatment planning system (TPS) at the Heidelberg Ion-Beam Therapy Center (HIT) is based on a fast performing analytical algorithm for dose calculation, relying, among others, on laterally integrated depth dose distributions (DDDs) simulated with the FLUKA Monte Carlo (MC) code. Important input parameters of these simulations need to be derived from a comparison of the simulated DDDs with measurements. In this work, the first measurements of (16)O ion DDDs at HIT are presented with a focus on the determined Bragg peak positions and the understanding of factors influencing the shape of the distributions. The measurements are compared to different simulation approaches aiming to reproduce the acquired data at best. A simplified geometrical model is first used to optimize important input parameters, not known a priori, in the simulations. This method is then compared to a more realistic, but also more time-consuming simulation approach better accounting for the experimental set-up and the measuring process. The results of this work contributed to a pre-clinical oxygen ion beam database, which is currently used by a research TPS for corresponding radio-biological cell experiments. A future extension to a clinical database used by the clinical TPS at HIT is foreseen. As a side effect, the performed investigations showed that the typical water equivalent calibration approach of experimental data acquired with water column systems leads to slight deviations between the experimentally determined and the real Bragg peak positions. For improved accuracy, the energy dependence of the stopping power, and herewith the water equivalent thickness, of the material downstream of the water tank should be considered in the analysis of measured data.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22805295     DOI: 10.1088/0031-9155/57/15/5017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

Review 1.  Charged-particle therapy in cancer: clinical uses and future perspectives.

Authors:  Marco Durante; Roberto Orecchia; Jay S Loeffler
Journal:  Nat Rev Clin Oncol       Date:  2017-03-14       Impact factor: 66.675

2.  New Ions for Therapy.

Authors:  Francesco Tommasino; Emanuele Scifoni; Marco Durante
Journal:  Int J Part Ther       Date:  2016-02-09

3.  Physics and biomedical challenges of cancer therapy with accelerated heavy ions.

Authors:  Marco Durante; Jürgen Debus; Jay S Loeffler
Journal:  Nat Rev Phys       Date:  2021-09-17

4.  A Monte Carlo-based treatment-planning tool for ion beam therapy.

Authors:  T T Böhlen; J Bauer; M Dosanjh; A Ferrari; T Haberer; K Parodi; V Patera; A Mairani
Journal:  J Radiat Res       Date:  2013-07       Impact factor: 2.724

5.  The FLUKA Code: An Accurate Simulation Tool for Particle Therapy.

Authors:  Giuseppe Battistoni; Julia Bauer; Till T Boehlen; Francesco Cerutti; Mary P W Chin; Ricardo Dos Santos Augusto; Alfredo Ferrari; Pablo G Ortega; Wioletta Kozłowska; Giuseppe Magro; Andrea Mairani; Katia Parodi; Paola R Sala; Philippe Schoofs; Thomas Tessonnier; Vasilis Vlachoudis
Journal:  Front Oncol       Date:  2016-05-11       Impact factor: 6.244

Review 6.  Monitoring of Hadrontherapy Treatments by Means of Charged Particle Detection.

Authors:  Silvia Muraro; Giuseppe Battistoni; Francesco Collamati; Erika De Lucia; Riccardo Faccini; Fernando Ferroni; Salvatore Fiore; Paola Frallicciardi; Michela Marafini; Ilaria Mattei; Silvio Morganti; Riccardo Paramatti; Luca Piersanti; Davide Pinci; Antoni Rucinski; Andrea Russomando; Alessio Sarti; Adalberto Sciubba; Elena Solfaroli-Camillocci; Marco Toppi; Giacomo Traini; Cecilia Voena; Vincenzo Patera
Journal:  Front Oncol       Date:  2016-08-03       Impact factor: 6.244

7.  Phase Space Generation for Proton and Carbon Ion Beams for External Users' Applications at the Heidelberg Ion Therapy Center.

Authors:  Thomas Tessonnier; Tiago Marcelos; Andrea Mairani; Stephan Brons; Katia Parodi
Journal:  Front Oncol       Date:  2016-01-11       Impact factor: 6.244

8.  Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams.

Authors:  Ivana Dokic; Andrea Mairani; Martin Niklas; Ferdinand Zimmermann; Naved Chaudhri; Damir Krunic; Thomas Tessonnier; Alfredo Ferrari; Katia Parodi; Oliver Jäkel; Jürgen Debus; Thomas Haberer; Amir Abdollahi
Journal:  Oncotarget       Date:  2016-08-30

9.  Fast robust dose calculation on GPU for high-precision 1H, 4He, 12C and 16O ion therapy: the FRoG platform.

Authors:  Stewart Mein; Kyungdon Choi; Benedikt Kopp; Thomas Tessonnier; Julia Bauer; Alfredo Ferrari; Thomas Haberer; Jürgen Debus; Amir Abdollahi; Andrea Mairani
Journal:  Sci Rep       Date:  2018-10-04       Impact factor: 4.379

10.  Characterization of the Mixed Radiation Field Produced by Carbon and Oxygen Ion Beams of Therapeutic Energy: A Monte Carlo Simulation Study.

Authors:  C K Ying; David Bolst; Anatoly Rosenfeld; Susanna Guatelli
Journal:  J Med Phys       Date:  2019-12-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.