Abstract

Performing coronary angiography in very older patients can prove a challenge due to vessels calcification and torturousity. Manipulation of coronary catheters to engage the artery ostium may result in over twisting and can result in complications ranging from a minor 'kink' to a complex 'knot'. The authors describe a novel method to retrieve the complex twisted coronary catheter using snare technique, after usual steps to remove the coronary catheter failed.

Entities:  

Mesh:

Year:  2010        PMID: 22798519      PMCID: PMC3029011          DOI: 10.1136/bcr.12.2009.2598

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  6 in total

1.  Percutaneous untying of a knot in a retained Swan-Ganz catheter.

Authors:  W A Bhatti; S Sinha; P Rowlands
Journal:  Cardiovasc Intervent Radiol       Date:  2000 May-Jun       Impact factor: 2.740

2.  Percutaneous removal of a knotted pulmonary artery catheter using sheaths and parallel crossing wires.

Authors:  Ron C Gaba; James T Bui; Derek L West; Charles A Owens
Journal:  J Vasc Interv Radiol       Date:  2007-06       Impact factor: 3.464

3.  Transfemoral percutaneous removal of a knotted Swan-Ganz catheter.

Authors:  Athanasios Katsikis; George Karavolias; Vassilios Voudris
Journal:  Catheter Cardiovasc Interv       Date:  2009-11-01       Impact factor: 2.692

Review 4.  Removal of knotted intravascular devices. Case report and review of the literature.

Authors:  I D Karanikas; A Polychronidis; A Vrachatis; D P Arvanitis; C E Simopoulos; M K Lazarides
Journal:  Eur J Vasc Endovasc Surg       Date:  2002-03       Impact factor: 7.069

5.  Unusual complication of Swan-Ganz catheter requiring mediastinotomy.

Authors:  S A Shenaq; G P Noon; J L Zamora; D H Morrow; D Hoover
Journal:  South Med J       Date:  1984-10       Impact factor: 0.954

6.  Minimally invasive retrieval of a dislodged Wallstent endoprosthesis after an endovascular abdominal aortic aneurysm repair.

Authors:  Russell C Lam; Soo J Rhee; Nicholas J Morrissey; James F McKinsey; Peter L Faries; K Craig Kent
Journal:  J Vasc Surg       Date:  2008-02       Impact factor: 4.268

  6 in total
  1 in total

1.  Transfemoral Technique to Untwist a Knotted Catheter in the Brachial Artery: A Case Report.

Authors:  Nathalie Noirclerc; Paul Alexandru Simion; Abdelkader Bakhti
Journal:  Maedica (Bucur)       Date:  2020-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.