Abstract

BACKGROUND: Most of current coronary CT angiography protocols are not adapted to body weight (BW) or cardiac output and no literature about influence of gender on coronary attenuation are reported with administration of a fixed iodine load per BW.
PURPOSE: To determine the influence of body mass index (BMI) and gender on coronary arterial attenuation if contrast material dose is linearly adjusted to a patient's BW at dual-source CT coronary angiography (DSCT-CA).
MATERIAL AND METHODS: A total of 207 consecutive patients (mean age 60.6 years) undergoing DSCT-CA were included. Contrast material (370 mg I/mL) dose calculation was randomly categorized into two groups (Group 1: 1.10 mL/kg for men and women; Group 2: men 1.10 mL/kg, women 0.99 mL/kg) and flow rate was calculated as dose was divided by scan time plus 8 s. Mean arterial attenuations between men and women were compared with respect to attenuations of ascending aorta (AA) above coronary ostia, left main coronary artery (LM), proximal segments of right coronary artery (RCA), left anterior descending (LAD), and left circumflex artery (LCX) in two groups, respectively. Attenuations of coronary arteries were correlated with BW and BMI with simple linear regression.
RESULTS: The mean attenuations of AA, LM, RCA, LAD, and LCX were 407.8 ± 53.6 HU, 412.6 ± 55.4 HU, 411.4 ± 64.3 HU, 399.1 ± 56.7 HU, and 399.1 ± 60.2 HU, respectively, and there were no significant differences between men and women in group 1 (AA, P = 0.571; LM, P = 0.670; RCA, P = 0.737; LAD, P = 0.439, and LCX, P = 0.888). In group 2, the mean attenuations of AA, LM, RCA, LAD, and LCX in men were significantly higher than those in women (AA, P = 0.008; LM, P = 0.025; RCA, P = 0.017; LAD, P = 0.015, and LCX, P = 0.002). Positive linear regression between BW and attenuations of AA (R(2) = 0.047, P = 0.02), LM (R(2) = 0.036, P = 0.04), RCA (R(2) = 0.080, P < 0.01), LAD (R(2) = 0.078, P < 0.01), and LCX (R(2) = 0.033, P = 0.05) was found in group 1, suggesting that attenuations of coronary arteries increased in heavier patients. Similarly, there was positive linear regression between BMI and attenuations of AA (R(2) = 0.117, P < 0.01), LM (R(2) = 0.090, P < 0.01), RCA (R(2) = 0.138, P < 0.01), LAD (R(2) = 0.111, P < 0.01), and LCX (R(2) = 0.078, P < 0.01).
CONCLUSION: Men and women have similar coronary attenuations with a fixed iodine load per BW. BMI has a positive linear influence on arterial attenuation at DSCT-CA involving injection protocol with dose linearly tailored to BW. Excessive contrast material may inadvertently be given in heavier patients when the dose is determined by BW only. Contrast material dose may need to be tailored individually by BW and BMI.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22798383     DOI: 10.1258/ar.2012.110657

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  6 in total

1.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

2.  Novel contrast-injection protocol for coronary computed tomographic angiography: contrast-injection protocol customized according to the patient's time-attenuation response.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Shinichi Nakamura; Kazuo Awai; Daisuke Utsunomiya; Tomohiro Namimoto; Kazunori Harada; Yasuyuki Yamashita
Journal:  Heart Vessels       Date:  2013-03-20       Impact factor: 2.037

3.  Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant article.

Authors:  Xiaomei Zhu; Yusheng Yu; Dinghu Xu; Hong Zhang; Lijun Tang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

4.  Fat volume measurements as a predictor of image noise in coronary computed tomography angiography.

Authors:  Rami M Abazid; Osama A Smettei; Ahmad Almeman; Sawsan Sayed; Hanaa Alsaqqa; Salma M Abdelmageed; Fahad J Alharbi; Abdullah M Alhabib; Mouaz H Al-Mallah
Journal:  J Saudi Heart Assoc       Date:  2018-11-17

5.  Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA.

Authors:  Shang Ge; Jian-Yao Zhu; Han Liu; Yuan Chen; Zhao-Huan Zhu
Journal:  Contrast Media Mol Imaging       Date:  2022-07-16       Impact factor: 3.009

6.  Feasibility of low contrast media volume in CT angiography of the aorta.

Authors:  Anna Seehofnerová; Madeleine Kok; Casper Mihl; Dave Douwes; Anni Sailer; Estelle Nijssen; Michiel J W de Haan; Joachim E Wildberger; Marco Das
Journal:  Eur J Radiol Open       Date:  2015-04-28