Literature DB >> 22789071

Patient-specific acetabular shape modelling: comparison among sphere, ellipsoid and conchoid parameterisations.

Pietro Cerveri1, Alfonso Manzotti, Guido Baroni.   

Abstract

The shape of the human acetabular cup was commonly represented as a hemisphere, but different geometries and patient-specific shapes have been recently proposed in the literature. Our aim was to test the limits of the sphericity assumption by comparing three different parameterisations, namely the sphere, the ellipsoid and the rotational conchoid. Models of hip surfaces, reconstructed from CT scans taken from Caucasian race cadavers and patients, were automatically processed to extract the acetabular surface. Two separate analyses were carried out on the overall acetabular shape, including both the acetabular fossa and the lunate surface (case A) and acetabular cup represented by the lunate surface only (case B). Nonlinear gradient-based and evolutionary computation approaches were implemented for the fitting process. Minor differences from the three idealised geometries were detected (median values of the fitting errors < 1 mm). Nonetheless, the sphere fitting was found to be statistically different from both the ellipsoid (p < 2.50e - 10) and the conchoid (p < 1.07e - 09), whereas no statistical difference was detected between the ellipsoid and the conchoid for case A. Significance of the difference between ellipsoid and sphere (p < 4.55e - 12) and between conchoid and sphere (p < 1.93e - 11) was found for case B as well. Interestingly, for case B statistical difference was detected between the ellipsoid and the conchoid. In conclusion, we synthesise that the morphology of the overall acetabular cup can be parameterised both with an ellipsoid shape and with a conchoid shape as well with superior quality than the simple sphere. Differently, if one considers just the lunate surface, better fitting results are expected when using the ellipsoid.

Entities:  

Mesh:

Year:  2012        PMID: 22789071     DOI: 10.1080/10255842.2012.702765

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  4 in total

Review 1.  Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning.

Authors:  Corinne R Henak; Andrew E Anderson; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

2.  Translatory hip kinematics measured with optoelectronic surgical navigation.

Authors:  Sima Zakani; John F Rudan; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-17       Impact factor: 2.924

3.  Three-dimensional quantification of femoral head shape in controls and patients with cam-type femoroacetabular impingement.

Authors:  Michael D Harris; Shawn P Reese; Christopher L Peters; Jeffrey A Weiss; Andrew E Anderson
Journal:  Ann Biomed Eng       Date:  2013-02-15       Impact factor: 3.934

4.  Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions.

Authors:  Chethan K N; Shyamasunder Bhat N; Zuber M; Satish Shenoy B
Journal:  J Biomed Phys Eng       Date:  2019-10-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.