Literature DB >> 22783760

Macroscopic and microscopic observations of needle insertion into gels.

Youri R J van Veen1, Alex Jahya, Sarthak Misra.   

Abstract

Needle insertion into soft tissue is one of the most common medical interventions. This study provides macroscopic and microscopic observations of needle-gel interactions. A gelatin mixture is used as a soft-tissue simulant. For the macroscopic studies, system parameters, such as insertion velocity, needle diameter, gel elasticity, needle tip shape (including bevel angle) and insertion motion profile, are varied, while the maximum insertion force and maximum needle deflection are recorded. The needle tip and gel interactions are observed using confocal microscopic images. Observations indicate that increasing the insertion velocity and needle diameter results in larger insertion forces and smaller needle deflections. Varying the needle bevel angle from 8 degrees to 82 degrees results in the insertion force increasing monotonically, while the needle deflection does not. These variations are due to the coupling between gel rupture and tip compression interactions, which are observed during microscopic studies. Increasing the gel elasticity results in larger insertion forces and needle deflections. Varying the tip shapes demonstrates that bevel-tipped needles produce the largest deflection, but insertion force does not vary among the tested tip shapes. Insertion with different motion profiles are performed. Results show that adding I Hz rotational motion during linear insertion decreases the needle deflection. Increasing the rotational motion from I Hz to 5 Hz decreases the insertion force, while the needle deflection remains the same. A high-velocity (250 mm/s and 300 mm/s) tapping during insertion yields no significant decrease in needle deflection and a slight increase in insertion force.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22783760     DOI: 10.1177/0954411912443207

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  10 in total

1.  Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images.

Authors:  Gustaaf J Vrooijink; Momen Abayazid; Sachin Patil; Ron Alterovitz; Sarthak Misra
Journal:  Int J Rob Res       Date:  2014-09       Impact factor: 4.703

2.  A combination of experimental and finite element analyses of needle-tissue interaction to compute the stresses and deformations during injection at different angles.

Authors:  Mahdi Halabian; Borhan Beigzadeh; Alireza Karimi; Hadi Asgharzadeh Shirazi; Mohammad Hasan Shaali
Journal:  J Clin Monit Comput       Date:  2015-10-29       Impact factor: 2.502

3.  Needle deflection estimation: prostate brachytherapy phantom experiments.

Authors:  Hossein Sadjadi; Keyvan Hashtrudi-Zaad; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-17       Impact factor: 2.924

Review 4.  Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.

Authors:  Pan Li; Zhiyong Yang; Shan Jiang
Journal:  Med Biol Eng Comput       Date:  2018-04-21       Impact factor: 2.602

5.  Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces.

Authors:  Momen Abayazid; Pedro Moreira; Navid Shahriari; Sachin Patil; Ron Alterovitz; Sarthak Misra
Journal:  Med Eng Phys       Date:  2014-10-31       Impact factor: 2.242

6.  Tip Design for Safety of Steerable Needles for Robot-Controlled Brain Insertion.

Authors:  Craig A Lehocky; Wendy Fellows-Mayle; Johnathan A Engh; Cameron N Riviere
Journal:  Robot Surg       Date:  2017-10-26

Review 7.  Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature.

Authors:  Chongjun Yang; Yu Xie; Shuang Liu; Dong Sun
Journal:  Sensors (Basel)       Date:  2018-02-12       Impact factor: 3.576

8.  Axially rigid steerable needle with compliant active tip control.

Authors:  M de Vries; J Sikorski; S Misra; J J van den Dobbelsteen
Journal:  PLoS One       Date:  2021-12-16       Impact factor: 3.240

9.  Electrochemotherapy treatment safety under parallel needle deflection.

Authors:  Daniella L L S Andrade; Raul Guedert; Guilherme B Pintarelli; Marcelo M M Rangel; Krishna D Oliveira; Priscila G Quadros; Daniela O H Suzuki
Journal:  Sci Rep       Date:  2022-02-17       Impact factor: 4.379

10.  Soft Tissue Phantoms for Realistic Needle Insertion: A Comparative Study.

Authors:  Alexander Leibinger; Antonio E Forte; Zhengchu Tan; Matthew J Oldfield; Frank Beyrau; Daniele Dini; Ferdinando Rodriguez Y Baena
Journal:  Ann Biomed Eng       Date:  2015-12-14       Impact factor: 3.934

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.