BACKGROUND: Hemoglobin (Hgb) determination is an essential part of donor qualification. We assessed and implemented a new spectrophotometer for donor Hgb determination. STUDY DESIGN AND METHODS: Precision, accuracy, and ease of use were assessed on a prototype DiaSpect analyzer (DiaSpect Medical, GmBH, Sailauf, Germany). A protocol to qualify the analyzer was developed and executed preimplementation. Samples were developed for periodic quality control (QC). Postimplementation performance was assessed based on QC results and trending of deferral rates.
RESULTS: Precision was excellent, with a coefficient of variation of 0.53%-1.14% per sample. The correlation coefficient between capillary DiaSpect and venous laboratory autoanalyzer measurements was 0.736. After 169 out of 223 analyzers failed to qualify on our initial protocol, all were successfully qualified with the use of a modified protocol, adjusted to avoid sources of variability. Because commercial controls proved inadequate, in-house samples were developed for periodic QC. Postimplementation, all analyzers had adequate QC results. Deferral rates decreased from 10.1 to 8.1% (p < 0.0001) for female donors and from 0.8 to 0.6% for male donors (p < 0.0001). The system was faster and easier to use compared with our previous two-step process.
CONCLUSION: We successfully implemented a new spectrophotometer, which resulted in greater efficiency, improved ease of use, and decreased deferrals.
© 2012 American Association of Blood Banks.

Entities:  

Mesh:

Year:  2012        PMID: 22780942     DOI: 10.1111/j.1537-2995.2012.03757.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  5 in total

1.  Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors.

Authors:  Abhay Singh; Anju Dubey; Atul Sonker; Rajendra Chaudhary
Journal:  Blood Transfus       Date:  2014-10-29       Impact factor: 3.443

Review 2.  Methods and analyzers for hemoglobin measurement in clinical laboratories and field settings.

Authors:  Ralph D Whitehead; Zuguo Mei; Carine Mapango; Maria Elena D Jefferds
Journal:  Ann N Y Acad Sci       Date:  2019-06-04       Impact factor: 5.691

Review 3.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

Review 4.  Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions.

Authors:  Rajendra Chaudhary; Anju Dubey; Atul Sonker
Journal:  J Blood Med       Date:  2017-07-03

5.  Validation of a hemoglobinometer for use in outdoor blood donation camps.

Authors:  Anju Dubey; Saurabh Murti
Journal:  Asian J Transfus Sci       Date:  2016 Jul-Dec