Literature DB >> 15546820

Effect on oximetry of dyes used for sentinel lymph node biopsy.

Antonio Piñero1, Julián Illana, Carlos García-Palenciano, Francisco Cañizarese, Manuel Canteras, Victoria Cañadillas, Eugenia Durán, Pascual Parilla.   

Abstract

HYPOTHESIS: There are differences between readings of peripheral blood oxygen saturation when the effect on saturation values of methylene blue is compared with that of isosulfan blue when used in sentinel lymph node biopsy in patients with breast cancer.
DESIGN: Prospective randomized study.
SETTING: University tertiary care center. PATIENTS: Thirty-two women undergoing surgery for breast cancer using sentinel lymph node biopsy.
INTERVENTIONS: Sentinel lymph node biopsy using methylene blue (16 patients) and isosulfan blue (16 patients); there was also a control group of 6 surgical patients in whom dyes were not used. MAIN OUTCOME MEASURES: Peripheral saturation of blood using pulse oximetry, oxygen saturation by blood-gas analysis, partial oxygen pressure by blood-gas analysis, and plasma dye levels, recorded before dye injection and 15, 30, and 60 minutes afterward.
RESULTS: The 2 dyes interfered with the peripheral saturation reading, but only isosulfan blue showed significant differences. The differences in blood-gas analysis values between the 2 groups and with regard to the controls were not significant.
CONCLUSIONS: Methylene blue interferes less than isosulfan blue in the peripheral saturation reading. Desaturation is factitious in both cases, and does not correspond to alterations in blood-gas analysis values.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15546820     DOI: 10.1001/archsurg.139.11.1204

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  5 in total

1.  Dyed but not dead.

Authors:  Shireen H Haque; Bobby D Nossaman
Journal:  Ochsner J       Date:  2012

2.  Injection of methylene blue solution into the inferior mesenteric artery of resected rectal specimens for rectal cancer as a method for increasing the lymph node harvest.

Authors:  E Klepšytė; N Evaldas Samalavičius
Journal:  Tech Coloproctol       Date:  2012-03-17       Impact factor: 3.781

Review 3.  Sentinel lymph node mapping in endometrial cancer: comparison of fluorescence dye with traditional radiocolloid and blue.

Authors:  Andrea Papadia; Maria Luisa Gasparri; Alessandro Buda; Michael D Mueller
Journal:  J Cancer Res Clin Oncol       Date:  2017-08-21       Impact factor: 4.553

4.  The effect of subareolar isosulfan blue injection on pulse oximeter readings.

Authors:  Baha Zengel; Ulkem Yararbas; Ozge Bingolballi; Ali Galip Denecli
Journal:  Indian J Surg       Date:  2012-06-27       Impact factor: 0.656

5.  Real-time assessment of cardiac perfusion, coronary angiography, and acute intravascular thrombi using dual-channel near-infrared fluorescence imaging.

Authors:  Eiichi Tanaka; Frederick Y Chen; Robert Flaumenhaft; Gwenda J Graham; Rita G Laurence; John V Frangioni
Journal:  J Thorac Cardiovasc Surg       Date:  2009-07       Impact factor: 5.209

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.