Literature DB >> 22771227

Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study.

Silvia Pianigiani1, Yan Chevalier, Luc Labey, Valerio Pascale, Bernardo Innocenti.   

Abstract

Total Knee Arthroplasty (TKA) is a very successful surgical procedure but clinical outcomes were reported to be affected by implant design, ligament balancing, alignment or patient-related anatomical factors. It was recently demonstrated that malpositioning of the TKA components and patient related anatomical factors can considerably alter tibio-femoral (TF) and patellofemoral maximum contact forces. However, up to now, how a component malpositioning and different soft-tissue anatomy changes TF knee kinematics was not yet fully investigated. The goal of this study was to evaluate how sensitive TF kinematics are to these factors during a simulated loaded squat for different TKA designs. Four TKA types (a fixed bearing, posterior stabilized prosthesis; a high flexion fixed bearing guided motion prosthesis; a mobile bearing prosthesis and a hinge prosthesis) were virtually implanted on the same virtual cadaver leg model which underwent a loaded squat between 0° and 120°. The reference models were then modified to simulate either component malpositioning in several directions or changes in ligaments geometry by change in the collateral ligament insertions. The results showed that, for all implant designs, TF kinematics were affected by changes in implant positioning and anatomical factors. While the ranges of motion predicted for all tested configurations were generally similar to the reference configuration for each type of TKA, the modifications resulted in shifts in the maximum and minimum values for the TF rotations and translations.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22771227     DOI: 10.1016/j.jbiomech.2012.06.014

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  12 in total

1.  A new spacer-guided, PCL balancing technique for cruciate-retaining total knee replacement.

Authors:  P J C Heesterbeek; L Labey; P Wong; B Innocenti; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-08       Impact factor: 4.342

2.  Knee kinetics and kinematics: What are the effects of TKA malconfigurations?

Authors:  Silvia Pianigiani; Luc Labey; Walter Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-24       Impact factor: 4.342

3.  Biomechanical Analysis of the Use of Stems in Revision Total Knee Arthroplasty.

Authors:  Bernardo Innocenti; Edoardo Bori; Silvia Pianigiani
Journal:  Bioengineering (Basel)       Date:  2022-06-19

4.  Finite element analysis of malposition in bi-unicompartmental knee arthroplasty.

Authors:  Nicola Armillotta; Edoardo Bori; Bernardo Innocenti
Journal:  Arch Orthop Trauma Surg       Date:  2022-10-20       Impact factor: 2.928

5.  All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.

Authors:  Jean Brihault; Alessandro Navacchia; Silvia Pianigiani; Luc Labey; Ronny De Corte; Valerio Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-10       Impact factor: 4.342

Review 6.  Sensitivity analysis of the material properties of different soft-tissues: implications for a subject-specific knee arthroplasty.

Authors:  Silvia Pianigiani; Davide Croce; Marta D'Aiuto; Walter Pascale; Bernardo Innocenti
Journal:  Muscles Ligaments Tendons J       Date:  2018-04-16

7.  A new graphical method to display data sets representing biomechanical knee behaviour.

Authors:  Silvia Pianigiani; Jos Vander Sloten; Walter Pascale; Luc Labey; Bernardo Innocenti
Journal:  J Exp Orthop       Date:  2015-08-28

Review 8.  Material models and properties in the finite element analysis of knee ligaments: a literature review.

Authors:  Fabio Galbusera; Maren Freutel; Lutz Dürselen; Marta D'Aiuto; Davide Croce; Tomaso Villa; Valerio Sansone; Bernardo Innocenti
Journal:  Front Bioeng Biotechnol       Date:  2014-11-17

9.  Assessment of patient functional performance in different knee arthroplasty designs during unconstrained squat.

Authors:  Federica Verdini; Claudio Zara; Tommaso Leo; Alessandro Mengarelli; Stefano Cardarelli; Bernardo Innocenti
Journal:  Muscles Ligaments Tendons J       Date:  2018-01-10

10.  Comparison of Kinematics in Cruciate Retaining and Posterior Stabilized for Fixed and Rotating Platform Mobile-Bearing Total Knee Arthroplasty with respect to Different Posterior Tibial Slope.

Authors:  Kyoung-Tak Kang; Yong-Gon Koh; Juhyun Son; Oh-Ryong Kwon; Jun-Sang Lee; Sae Kwang Kwon
Journal:  Biomed Res Int       Date:  2018-06-11       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.