Literature DB >> 22771092

Metal ion levels not sufficient as a screening measure for adverse reactions in metal-on-metal hip arthroplasties.

Rory D Macnair1, Henry Wynn-Jones, James A Wimhurst, Andoni Toms, John Cahir.   

Abstract

This study aims to assess the accuracy of metal ion analysis in the diagnosis of adverse reaction to metal debris (ARMD) in patients with metal-on-metal hip arthroplasties by comparing the cobalt and chromium levels in 57 patients (62 hips) to findings on metal artifact reduction magnetic resonance imaging (MRI). An ARMD was detected using MRI in 18 (29%) of the hips. Forty patients had cobalt levels less than 7 μg/L, and 33 had chromium levels less than 7 μg/L, but 8 of these had an ARMD on MRI and only minimal symptoms (Oxford Hip Score ≥ 44/48). The incidence of ARMD was significantly higher when chromium concentration was above 7 μg/L (P = .02), but normal metal ion levels can be misleading and metal artifact reduction MRI imaging is advised in all patients.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22771092     DOI: 10.1016/j.arth.2012.05.029

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  13 in total

1.  MRI of THA Correlates With Implant Wear and Tissue Reactions: A Cross-sectional Study.

Authors:  Matthew F Koff; Christina Esposito; Parina Shah; Mauro Miranda; Elexis Baral; Kara Fields; Thomas Bauer; Douglas E Padgett; Timothy Wright; Hollis G Potter
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

2.  601 metal-on-metal total hip replacements with 36 mm heads a 5 minimum year follow up: Levels of ARMD remain low despite a comprehensive screening program.

Authors:  Amit Atrey; Alister Hart; Nasir Hussain; Jonathon Waite; Andrew J Shepherd; Steve Young
Journal:  J Orthop       Date:  2016-10-31

3.  Mid- to long-term results of resurfacing hip arthroplasty in Japanese patients: a comparison of osteoarthritic vs non-osteoarthritic patients.

Authors:  Daisuke Inoue; Tamon Kabata; Yoshitomo Kajino; Tomoharu Takagi; Takaaki Ohmori; Junya Yoshitani; Takuro Ueno; Hiroyuki Tsuchiya
Journal:  J Artif Organs       Date:  2018-10-28       Impact factor: 1.731

Review 4.  Clinical features, testing, and management of patients with suspected prosthetic hip-associated cobalt toxicity: a systematic review of cases.

Authors:  John J Devlin; Adam C Pomerleau; Jeffrey Brent; Brent W Morgan; Scott Deitchman; Michael Schwartz
Journal:  J Med Toxicol       Date:  2013-12

5.  Adverse reaction to metal debris after Birmingham hip resurfacing arthroplasty.

Authors:  Mika Junnila; Matti Seppänen; Jari Mokka; Petri Virolainen; Tuukka Pölönen; Tero Vahlberg; Kimmo Mattila; Esa K J Tuominen; Juho Rantakokko; Ville Äärimaa; Ari Itälä; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2015-01-13       Impact factor: 3.717

6.  The biological response to nanometre-sized polymer particles.

Authors:  Aiqin Liu; Laura Richards; Catherine L Bladen; Eileen Ingham; John Fisher; Joanne L Tipper
Journal:  Acta Biomater       Date:  2015-05-22       Impact factor: 8.947

7.  Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty.

Authors:  Jari Mokka; Mika Junnila; Matti Seppänen; Petri Virolainen; Tuukka Pölönen; Tero Vahlberg; Kimmo Mattila; Esa K J Tuominen; Juho Rantakokko; Ville Aärimaa; Juha Kukkonen; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2013-10-31       Impact factor: 3.717

8.  Generation of a large volume of clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles for cell culture studies.

Authors:  Aiqin Liu; Eileen Ingham; John Fisher; Joanne L Tipper
Journal:  Proc Inst Mech Eng H       Date:  2014-03-21       Impact factor: 1.617

Review 9.  Imaging Metal-on-Metal Hip Replacements: the Norwich Experience.

Authors:  Marianna S Thomas; James A Wimhurst; John F Nolan; Andoni P Toms
Journal:  HSS J       Date:  2013-08-24

10.  Blood metal ion levels are not a useful test for adverse reactions to metal debris: A systematic review and meta-analysis.

Authors:  M Pahuta; J M Smolders; J L van Susante; J Peck; P R Kim; P E Beaule
Journal:  Bone Joint Res       Date:  2016-09       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.