Literature DB >> 22757504

Proximal versus distal control of two-joint planar reaching movements in the presence of neuromuscular noise.

Hung P Nguyen1, Jonathan B Dingwell.   

Abstract

Determining how the human nervous system contends with neuro-motor noise is vital to understanding how humans achieve accurate goal-directed movements. Experimentally, people learning skilled tasks tend to reduce variability in distal joint movements more than in proximal joint movements. This suggests that they might be imposing greater control over distal joints than proximal joints. However, the reasons for this remain unclear, largely because it is not experimentally possible to directly manipulate either the noise or the control at each joint independently. Therefore, this study used a 2 degree-of-freedom torque driven arm model to determine how different combinations of noise and/or control independently applied at each joint affected the reaching accuracy and the total work required to make the movement. Signal-dependent noise was simultaneously and independently added to the shoulder and elbow torques to induce endpoint errors during planar reaching. Feedback control was then applied, independently and jointly, at each joint to reduce endpoint error due to the added neuromuscular noise. Movement direction and the inertia distribution along the arm were varied to quantify how these biomechanical variations affected the system performance. Endpoint error and total net work were computed as dependent measures. When each joint was independently subjected to noise in the absence of control, endpoint errors were more sensitive to distal (elbow) noise than to proximal (shoulder) noise for nearly all combinations of reaching direction and inertia ratio. The effects of distal noise on endpoint errors were more pronounced when inertia was distributed more toward the forearm. In contrast, the total net work decreased as mass was shifted to the upper arm for reaching movements in all directions. When noise was present at both joints and joint control was implemented, controlling the distal joint alone reduced endpoint errors more than controlling the proximal joint alone for nearly all combinations of reaching direction and inertia ratio. Applying control only at the distal joint was more effective at reducing endpoint errors when more of the mass was more proximally distributed. Likewise, controlling the distal joint alone required less total net work than controlling the proximal joint alone for nearly all combinations of reaching distance and inertia ratio. It is more efficient to reduce endpoint error and energetic cost by selectively applying control to reduce variability in the distal joint than the proximal joint. The reasons for this arise from the biomechanical configuration of the arm itself.

Entities:  

Mesh:

Year:  2012        PMID: 22757504      PMCID: PMC5413135          DOI: 10.1115/1.4006811

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  51 in total

1.  Role of cocontraction in arm movement accuracy.

Authors:  Paul L Gribble; Lucy I Mullin; Nicholas Cothros; Andrew Mattar
Journal:  J Neurophysiol       Date:  2003-01-22       Impact factor: 2.714

2.  Optimal feedback control as a theory of motor coordination.

Authors:  Emanuel Todorov; Michael I Jordan
Journal:  Nat Neurosci       Date:  2002-11       Impact factor: 24.884

3.  Bayesian integration in sensorimotor learning.

Authors:  Konrad P Körding; Daniel M Wolpert
Journal:  Nature       Date:  2004-01-15       Impact factor: 49.962

4.  General coordination of shoulder, elbow and wrist dynamics during multijoint arm movements.

Authors:  James C Galloway; Gail F Koshland
Journal:  Exp Brain Res       Date:  2001-12-06       Impact factor: 1.972

5.  A clinically applicable model to estimate the opposing muscle groups contributions to isometric and dynamic tasks.

Authors:  Pauline Gerus; Guillaume Rao; Thomas S Buchanan; Eric Berton
Journal:  Ann Biomed Eng       Date:  2010-03-09       Impact factor: 3.934

6.  The role of intrinsic factors in control of arm movement direction: implications from directional preferences.

Authors:  Natalia Dounskaia; Jacob A Goble; Wanyue Wang
Journal:  J Neurophysiol       Date:  2010-12-01       Impact factor: 2.714

7.  An organizing principle for a class of voluntary movements.

Authors:  N Hogan
Journal:  J Neurosci       Date:  1984-11       Impact factor: 6.167

8.  The coordination of arm movements: an experimentally confirmed mathematical model.

Authors:  T Flash; N Hogan
Journal:  J Neurosci       Date:  1985-07       Impact factor: 6.167

9.  Optimal trajectory formation of constrained human arm reaching movements.

Authors:  Ken Ohta; Mikhail M Svinin; ZhiWei Luo; Shigeyuki Hosoe; Rafael Laboissière
Journal:  Biol Cybern       Date:  2004-08-09       Impact factor: 2.086

10.  Directional biases reveal utilization of arm's biomechanical properties for optimization of motor behavior.

Authors:  Jacob A Goble; Yanxin Zhang; Yury Shimansky; Siddharth Sharma; Natalia V Dounskaia
Journal:  J Neurophysiol       Date:  2007-07-11       Impact factor: 2.714

View more
  4 in total

1.  Locomotor control of limb force switches from minimal intervention principle in early adaptation to noise reduction in late adaptation.

Authors:  Brian P Selgrade; Young-Hui Chang
Journal:  J Neurophysiol       Date:  2014-12-04       Impact factor: 2.714

2.  A Hybrid Framework for Understanding and Predicting Human Reaching Motions.

Authors:  Ozgur S Oguz; Zhehua Zhou; Dirk Wollherr
Journal:  Front Robot AI       Date:  2018-03-27

3.  INFLUENCE OF FOAM ROLLING ON ELBOW PROPRIOCEPTION, STRENGTH, AND FUNCTIONAL MOTOR PERFORMANCE.

Authors:  Fatma Ozden; Sevgi Sevi Yesilyaprak
Journal:  J Athl Train       Date:  2021-02-24       Impact factor: 3.824

4.  An Inverse Optimal Control Approach to Explain Human Arm Reaching Control Based on Multiple Internal Models.

Authors:  Ozgur S Oguz; Zhehua Zhou; Stefan Glasauer; Dirk Wollherr
Journal:  Sci Rep       Date:  2018-04-03       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.