Literature DB >> 22754200

Electro and Magneto-Electropolished Surface Micro-Patterning on Binary and Ternary Nitinol.

Dharam Persaud-Sharma1, Norman Munroe, Anthony McGoron.   

Abstract

In this study, an Atomic Force Microscopy (AFM) roughness analysis was performed on non-commercial Nitinol alloys with Electropolished (EP) and Magneto-Electropolished (MEP) surface treatments and commercially available stents by measuring Root-Mean-Square (RMS), Average Roughness (Ra), and Surface Area (SA) values at various dimensional areas on the alloy surfaces, ranging from (800 × 800 nm) to (115 × 115μm), and (800 × 800 nm) to (40 × 40 μm) on the commercial stents. Results showed that NiTi-Ta 10 wt% with an EP surface treatment yielded the highest overall roughness, while the NiTi-Cu 10 wt% alloy had the lowest roughness when analyzed over (115 × 115 μm). Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) analysis revealed unique surface morphologies for surface treated alloys, as well as an aggregation of ternary elements Cr and Cu at grain boundaries in MEP and EP surface treated alloys, and non-surface treated alloys. Such surface micro-patterning on ternary Nitinol alloys could increase cellular adhesion and accelerate surface endothelialization of endovascular stents, thus reducing the likelihood of in-stent restenosis and provide insight into hemodynamic flow regimes and the corrosion behavior of an implantable device influenced from such surface micro-patterns.

Entities:  

Year:  2012        PMID: 22754200      PMCID: PMC3384495     

Source DB:  PubMed          Journal:  Trends Biomater Artif Organs        ISSN: 0971-1198


  18 in total

Review 1.  Implant surfaces and interface processes.

Authors:  B Kasemo; J Gold
Journal:  Adv Dent Res       Date:  1999-06

2.  Influence of surface topography on endothelialization of intravascular metallic material.

Authors:  J C Palmaz; A Benson; E A Sprague
Journal:  J Vasc Interv Radiol       Date:  1999-04       Impact factor: 3.464

3.  Atomic force microscopy study of stainless-steel and nickel-titanium files.

Authors:  Caroline R A Valois; Luciano P Silva; Ricardo B Azevedo
Journal:  J Endod       Date:  2005-12       Impact factor: 4.171

4.  The threshold at which substrate nanogroove dimensions may influence fibroblast alignment and adhesion.

Authors:  W A Loesberg; J te Riet; F C M J M van Delft; P Schön; C G Figdor; S Speller; J J W A van Loon; X F Walboomers; J A Jansen
Journal:  Biomaterials       Date:  2007-06-18       Impact factor: 12.479

5.  Increased endothelial cell adhesion and elongation on micron-patterned nano-rough poly(dimethylsiloxane) films.

Authors:  Ashwini Ranjan; Thomas J Webster
Journal:  Nanotechnology       Date:  2009-07-07       Impact factor: 3.874

6.  Microfluidic device for label-free measurement of platelet activation.

Authors:  David W Inglis; Keith J Morton; John A Davis; Thomas J Zieziulewicz; David A Lawrence; Robert H Austin; James C Sturm
Journal:  Lab Chip       Date:  2008-04-11       Impact factor: 6.799

7.  Expandable tubular stents for treatment of arterial occlusive diseases: experimental and clinical results. Work in progress.

Authors:  E P Strecker; D Liermann; K H Barth; H R Wolf; N Freudenberg; G Berg; M Westphal; P Tsikuras; M Savin; B Schneider
Journal:  Radiology       Date:  1990-04       Impact factor: 11.105

8.  Fabrication, characterization, and biological assessment of multilayered DNA-coatings for biomaterial purposes.

Authors:  Jeroen J J P van den Beucken; Matthijn R J Vos; Peter C Thüne; Tohru Hayakawa; Tadao Fukushima; Yoshio Okahata; X Frank Walboomers; Nico A J M Sommerdijk; Roeland J M Nolte; John A Jansen
Journal:  Biomaterials       Date:  2005-08-01       Impact factor: 12.479

9.  A Comparative Biocompatibility Analysis of Ternary Nitinol Alloys.

Authors:  Waseem Haider; Norman Munroe; Chandan Pulletikurthi; Puneet K Singh Gill; Sushma Amruthaluri
Journal:  J Mater Eng Perform       Date:  2009-08-01       Impact factor: 1.819

10.  Self-expanding nitinol stents in canine vertebral arteries: hemodynamics and tissue response.

Authors:  A K Wakhloo; F O Tio; B B Lieber; F Schellhammer; M Graf; L N Hopkins
Journal:  AJNR Am J Neuroradiol       Date:  1995-05       Impact factor: 3.825

View more
  4 in total

1.  Surface modification of Ni-Ti alloys for stent application after magnetoelectropolishing.

Authors:  Puneet Gill; Vishal Musaramthota; Norman Munroe; Amit Datye; Rupak Dua; Waseem Haider; Anthony McGoron; Ryszard Rokicki
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2015-01-07       Impact factor: 7.328

2.  Biocompatibility Assessment of Novel Bioresorbable Alloys Mg-Zn-Se and Mg-Zn-Cu for Endovascular Applications: In- Vitro Studies.

Authors:  Dharam Persaud-Sharma; Noah Budiansky; Anthony J McGoron
Journal:  J Biomim Biomater Tissue Eng       Date:  2013

3.  Mechanical Properties and Tensile Failure Analysis of Novel Bio-absorbable Mg-Zn-Cu and Mg-Zn-Se Alloys for Endovascular Applications.

Authors:  Dharam Persaud-Sharma; Noah Budiansky; Anthony J McGoron
Journal:  Metals (Basel)       Date:  2012-12-21       Impact factor: 2.351

4.  Corono-radicular reinforcement with minimal invasion: A novel case report.

Authors:  Tasneem Alirajpurwala; Murtuza Zhabuawala; Roopa R Nadig
Journal:  J Conserv Dent       Date:  2022-05-02
  4 in total