| Literature DB >> 22737445 |
A Hadadi1, M J Zehtab, H Babagolzadeh, H Ashraf.
Abstract
BACKGROUND: In spite of decreasing incidence of orthopedic device-related infections to 1%, nowadays, device-related infection still remains a diagnostic, therapeutic and cost-related problem. The objective of this study is to evaluate the contributing risk factors for orthopedic device-related infections in Sina Hospital, Tehran, Iran.Entities:
Keywords: Implant surgery; Infection; Microorganisms; Orthopedic devices
Year: 2011 PMID: 22737445 PMCID: PMC3371915
Source DB: PubMed Journal: Iran Red Crescent Med J ISSN: 2074-1804 Impact factor: 0.611
Basic characteristics of orthopedic patients underwent device implantation.
| Mean age in years (SE) | 40.96 (1.79) | 35.65 (1.15) |
| Gender (M/F) | 84/26 | 176/44 |
| Wound class N (%) | ||
| Clean | 26 (23.6) | 166 (75.5) |
| Clean-contaminated | 2 (1.8) | 1 (0.5) |
| Dirty | 82 (74.5) | 53 (24.1) |
| Device (N) | ||
| Fixator (External/ Internal) | (28/83) | (16/196) |
| Prosthesis (hip/knee) | (1/2) | (8/10) |
| Timing of surgery N (%) | ||
| Emergency | 2 (1.8) | 1 (0.5) |
| Elective | 108 (98.2) | 219 (99.5) |
| Type of anesthesia N (%) | ||
| Local | 50 (45.5) | 94 (42.7) |
| General | 56 (50.9) | 122 (55.5) |
| Both | 4 (3.6) | 4 (1.8) |
a Twelve patients had infections of both internal and external fixators together.
Association between orthopedic device-related infections and investigated factors, according to univariate logistic regression analysis.
| Age (years, mean) | 40.96 (1.79) | 35.65 (1.15) | 1.02 | 1.0–1.03 | .0120 |
| Dirty wound class procedure | 82 (74.5) | 53 (24.1) | 9.22 | 5.43–15.66 | <0.001 |
| Motor-vehicle-related trauma | 83 (75.5) | 129 (58.6) | 2.69 | 1.30–3.51 | 0.003 |
| External Fixator | 24 (21.8) | 6 (2.7) | 4.35 | 22.24–8.47 | <0.001 |
| Underlying diseases | 13 (11.8) | 2 (0.9) | 14.61 | 3.23–65.98 | <0.001 |
| Addiction | 15 (12.6) | 7 (3.2) | 4.81 | 1.89–12.17 | <0.001 |
a ODRI, orthopedic device related infection
Independent risk factors for device-related infections in orthopedic patients from multiple regression models.
| Dirty wound class Procedure | 9.96 | 4.96–20.06 | <0.001 |
| External fixator | 7.35 | 2.54–21.28 | <0.001 |
| Underlying diseases | 16.39 | 3.08–83.33 | 0.001 |
| Addiction | 4.081 | 1.31–12.82 | 0.015 |