Non-contact biomedical photoacoustic and ultrasound imaging.

Guy Rousseau1, Bruno Gauthier, Alain Blouin, Jean-Pierre Monchalin.   

Abstract

The detection of ultrasound in photoacoustic tomography (PAT) usually relies on ultrasonic transducers in contact with the biological tissue through a coupling medium. This is a major drawback for important potential applications such as surgery. Here we report the use of a remote optical method, derived from industrial laser-ultrasonics, to detect ultrasound in tissues. This approach enables non-contact PAT (NCPAT) without exceeding laser exposure safety limits. The sensitivity of the method is based on the use of suitably shaped detection laser pulses and a confocal Fabry-Perot interferometer in differential configuration. Reliable image reconstruction is obtained by measuring remotely the surface profile of the tissue with an optical coherence tomography system. The proposed method also allows non-contact ultrasound imaging (US) by applying a second reconstruction algorithm to the data acquired for NCPAT. Endogenous and exogenous inclusions exhibiting optical and acoustic contrasts were detected ex vivo in chicken breast and calf brain specimens. Inclusions down to 0.3 mm in size were detected at depths exceeding 1 cm. The method could expand the scope of photoacoustic and US to in-vivo biomedical applications where contact is impractical.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22734747     DOI: 10.1117/1.JBO.17.6.061217

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  17 in total

1.  Non-contact photoacoustic imaging using a fiber based interferometer with optical amplification.

Authors:  Armin Hochreiner; Johannes Bauer-Marschallinger; Peter Burgholzer; Bernhard Jakoby; Thomas Berer
Journal:  Biomed Opt Express       Date:  2013-10-02       Impact factor: 3.732

2.  Theoretical and experimental studies of distance dependent response of micro-ring resonator-based ultrasonic detectors for photoacoustic microscopy.

Authors:  Zhen Zhang; Biqin Dong; Hao Li; Fan Zhou; Hao F Zhang; Cheng Sun
Journal:  J Appl Phys       Date:  2014-10-08       Impact factor: 2.546

3.  Simultaneous viewing of individual cells and ambient microvasculature using optical absorption and fluorescence contrasts.

Authors:  Zhixing Xie; Sung-Liang Chen; Mario L Fabiilli; J Brian Fowlkes; K Kirk Shung; Qifa Zhou; Paul L Carson; Xueding Wang
Journal:  Mol Imaging       Date:  2013 Nov-Dec       Impact factor: 4.488

4.  Non-Contact Photoacoustic Imaging Using a Commercial Heterodyne Interferometer.

Authors:  Chao Tian; Ting Feng; Cheng Wang; Shengchun Liu; Qian Cheng; David E Oliver; Xueding Wang; Guan Xu
Journal:  IEEE Sens J       Date:  2016-09-20       Impact factor: 3.301

5.  Complete-noncontact photoacoustic microscopy by detection of initial pressures using a 3×3 coupler-based fiber-optic interferometer.

Authors:  Yi Wang; Yingxin Hu; Binyang Peng; Hongxian Zhou; Yuqian Zhao; Zhenhe Ma
Journal:  Biomed Opt Express       Date:  2019-12-24       Impact factor: 3.732

6.  Assessment of microvasculature flow state with a high speed all-optic dual-modal system of optical coherence tomography and photoacoustic imaging.

Authors:  Zhenhe Ma; Shuzhuo Luo; Menghan Yu; Jian Liu; Yuqian Zhao; Yao Yu; Jiangtao Lv; Xiaofang Zhang; Yi Wang
Journal:  Biomed Opt Express       Date:  2018-11-08       Impact factor: 3.732

Review 7.  Optical Detection of Ultrasound in Photoacoustic Imaging.

Authors:  Biqin Dong; Cheng Sun; Hao F Zhang
Journal:  IEEE Trans Biomed Eng       Date:  2016-09-01       Impact factor: 4.538

8.  A transparent broadband ultrasonic detector based on an optical micro-ring resonator for photoacoustic microscopy.

Authors:  Hao Li; Biqin Dong; Zhen Zhang; Hao F Zhang; Cheng Sun
Journal:  Sci Rep       Date:  2014-03-28       Impact factor: 4.379

9.  Dual Modality Noncontact Photoacoustic and Spectral Domain OCT Imaging.

Authors:  Elisabeth Leiss-Holzinger; Johannes Bauer-Marschallinger; Armin Hochreiner; Philipp Hollinger; Thomas Berer
Journal:  Ultrason Imaging       Date:  2015-04-21       Impact factor: 1.578

10.  NDT of fiber-reinforced composites with a new fiber-optic pump-probe laser-ultrasound system.

Authors:  Ivan Pelivanov; Takashi Buma; Jinjun Xia; Chen-Wei Wei; Matthew O'Donnell
Journal:  Photoacoustics       Date:  2014-02-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.