Literature DB >> 22733703

T2*-relaxivity contrast imaging: first results.

Steven Sourbron1, Melanie Heilmann, Christine Walczak, Julien Vautier, Lothar R Schad, Andreas Volk.   

Abstract

In this study, T2*- relaxivity contrast imaging (RCI) is proposed for new contrast generation in MRI. The method produces images of relaxivities r*2,vasc and r*2,EES caused by susceptibility gradients across the vessel walls and cell membranes, respectively. The sensitivity to noise was assessed with a simulation study, and initial results are presented for five colorectal tumor xenografts in nude mice. Simulations show that the new relaxivity parameters are at least as accurate and precise as standard parameters such as plasma volume and interstitial volume. Mean values of both relaxivities were significantly different (r*2,vasc=10.9±2.9 mM(-1) s(-1) and r*2,EES=15.6±2.6 mM(-1) s(-1)). r*2,vasc (r=0.67) and r*2,EES (r=0.52) were weakly correlated with plasma volume and interstitial volume, respectively. Images of r*2,vasc and r*2,EES reveal a different tumor structure than plasma volume and interstitial volume maps. These results suggest that relaxivity contrast imaging is practically feasible and might offer supplementary information compared to dynamic contrast-enhanced-MRI.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22733703     DOI: 10.1002/mrm.24383

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Systematic assessment of multi-echo dynamic susceptibility contrast MRI using a digital reference object.

Authors:  Ashley M Stokes; Natenael B Semmineh; Ashley Nespodzany; Laura C Bell; C Chad Quarles
Journal:  Magn Reson Med       Date:  2019-08-09       Impact factor: 4.668

2.  Validation of a T1 and T2* leakage correction method based on multiecho dynamic susceptibility contrast MRI using MION as a reference standard.

Authors:  Ashley M Stokes; Natenael Semmineh; C Chad Quarles
Journal:  Magn Reson Med       Date:  2015-09-12       Impact factor: 4.668

3.  Assessing tumor cytoarchitecture using multiecho DSC-MRI derived measures of the transverse relaxivity at tracer equilibrium (TRATE).

Authors:  Natenael B Semmineh; Junzhong Xu; Jack T Skinner; Jingping Xie; Hua Li; Gregory Ayers; C Chad Quarles
Journal:  Magn Reson Med       Date:  2014-09-16       Impact factor: 4.668

4.  An efficient computational approach to characterize DSC-MRI signals arising from three-dimensional heterogeneous tissue structures.

Authors:  Natenael B Semmineh; Junzhong Xu; Jerrold L Boxerman; Gary W Delaney; Paul W Cleary; John C Gore; C Chad Quarles
Journal:  PLoS One       Date:  2014-01-08       Impact factor: 3.240

5.  A Population-Based Digital Reference Object (DRO) for Optimizing Dynamic Susceptibility Contrast (DSC)-MRI Methods for Clinical Trials.

Authors:  Natenael B Semmineh; Ashley M Stokes; Laura C Bell; Jerrold L Boxerman; C Chad Quarles
Journal:  Tomography       Date:  2017-03

6.  A simulation tool for dynamic contrast enhanced MRI.

Authors:  Nicolas Adrien Pannetier; Clément Stéphan Debacker; Franck Mauconduit; Thomas Christen; Emmanuel Luc Barbier
Journal:  PLoS One       Date:  2013-03-14       Impact factor: 3.240

7.  Evaluation of Amyotrophic Lateral Sclerosis-Induced Muscle Degeneration Using Magnetic Resonance-Based Relaxivity Contrast Imaging (RCI).

Authors:  Sudarshan Ragunathan; Laura C Bell; Natenael Semmineh; Ashley M Stokes; Jeremy M Shefner; Robert Bowser; Shafeeq Ladha; C Chad Quarles
Journal:  Tomography       Date:  2021-05-05
  7 in total