Literature DB >> 22733429

The usefulness of near-infrared spectroscopy in the anesthetic management of endovascular aortic aneurysm repair.

Masahiro M Wakimoto1, Mamoru Kadosaki, Hirofumi Nagata, Kenji S Suzuki.   

Abstract

Near-infrared spectroscopy (NIRS) may be a useful method for monitoring the regional oxygen saturation (rSO(2)) of the lower extremity during endovascular aortic repair. Eighteen patients with thoracic descending and/or abdominal aortic aneurysm were enrolled in this study. NIRS probes were placed bilaterally on the calves. Muscular rSO(2) (mrSO(2)) was monitored every 30 s throughout the operation. In the leg in which the femoral artery was clamped, mrSO(2) values were selected at 3 or 4 points-just before clamping (control value), 30 min after clamping, 10 min after the first declamping, and 10 min after the second declamping following repair of the femoral artery, if necessary. In all patients, mrSO(2) decreased significantly during clamping, from 64 ± 11 % (mean ± SD) of the control value to 32 ± 15 %. After declamping, mrSO(2) recovered to 69 ± 14 % of the control value in 16 patients. In the 2 other patients, however, mrSO(2) did not recover after the first declamping, because of femoral artery dissection. After additional repair, mrSO(2) recovered quickly to the control value. These data suggested NIRS may objectively and quantitatively reflect oxygenation of the lower extremities, and may indicate an ischemic event that needs additional repair during endovascular aortic repair.

Entities:  

Mesh:

Year:  2012        PMID: 22733429     DOI: 10.1007/s00540-012-1435-1

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  22 in total

1.  Preoperative cerebral oxygen saturation and clinical outcomes in cardiac surgery.

Authors:  Matthias Heringlake; Christof Garbers; Jan-Hendrik Käbler; Ingrid Anderson; Hermann Heinze; Julika Schön; Klaus-Ulrich Berger; Leif Dibbelt; Hans-Hinrich Sievers; Thorsten Hanke
Journal:  Anesthesiology       Date:  2011-01       Impact factor: 7.892

Review 2.  Neurological monitoring for congenital heart surgery.

Authors:  Dean B Andropoulos; Stephen A Stayer; Laura K Diaz; Chandra Ramamoorthy
Journal:  Anesth Analg       Date:  2004-11       Impact factor: 5.108

3.  Distal leg protection for peripheral cannulation in minimally invasive and totally endoscopic cardiac surgery.

Authors:  Nikolaos Bonaros; Dominik Wiedemann; Johann Nagiller; Gudrun Feuchtner; Christian Kolbitsch; Marc Kaufmann; Johannes Bonatti; Thomas Schachner
Journal:  Heart Surg Forum       Date:  2009-06       Impact factor: 0.676

4.  Cerebral NIRS as a marker of superior vena cava oxygen saturation in neonates with congenital heart disease.

Authors:  Zaccaria Ricci; Cristiana Garisto; Isabella Favia; Ulrike Schloderer; Chiara Giorni; Tiziana Fragasso; Sergio Picardo
Journal:  Paediatr Anaesth       Date:  2010-11       Impact factor: 2.556

5.  Monitoring of skeletal muscle oxygenation using near-infrared spectroscopy during abdominal aortic surgery.

Authors:  Masayasu Nakayama; Soushi Iwasaki; Hiromichi Ichinose; Shuji Yamamoto; Noriaki Kanaya; Akiyoshi Namiki
Journal:  J Anesth       Date:  2002       Impact factor: 2.078

6.  Primary stenting immediatly after surgery in occluded anastomoses of aortoaortic tube graft: a case report.

Authors:  M Rabellino; L García-Nielsen; T Zander; S Baldi; A Estigarribia; I Zerolo; H Cheves; R Llorens; M Maynar
Journal:  Cardiol Res Pract       Date:  2010-07-20       Impact factor: 1.866

7.  Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.

Authors:  Stefan Moritz; Piotr Kasprzak; Matthias Arlt; Kai Taeger; Christoph Metz
Journal:  Anesthesiology       Date:  2007-10       Impact factor: 7.892

8.  Use of near-infrared spectroscopic measurement at the buttocks during abdominal aortic surgery.

Authors:  Daisuke Fukui; Hiroaki Urayama; Kenichi Tanaka; Seiji Kawasaki
Journal:  Circ J       Date:  2002-12       Impact factor: 2.993

9.  Evaluation of buttock claudication with hypogastric artery stump pressure measurement and near infrared spectroscopy after abdominal aortic aneurysm repair.

Authors:  N Sugano; Y Inoue; T Iwai
Journal:  Eur J Vasc Endovasc Surg       Date:  2003-07       Impact factor: 7.069

10.  Multicenter prospective study of nonruptured abdominal aortic aneurysm. Part II. Variables predicting morbidity and mortality.

Authors:  K W Johnston
Journal:  J Vasc Surg       Date:  1989-03       Impact factor: 4.268

View more
  1 in total

1.  Ascending Aortic Repair and Simultaneous Femoro-Femoral Crossover Bypass for Acute DeBakey Type I Dissection with Leg Ischemia.

Authors:  Christian Olsson
Journal:  Aorta (Stamford)       Date:  2014-12-01
  1 in total