Literature DB >> 2271763

Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models.

D E Mann1, J M Tarbell.   

Abstract

The influence of non-Newtonian rheology on wall shear rate in steady and oscillatory flow through rigid curved and straight artery models was studied experimentally. Wall shear rates measured by flush mounted hot film anemometry under nearly identical flow conditions are reported for the following four fluids: aqueous glycerin (Newtonian), aqueous polyacrylamide (shear thinning, highly elastic), aqueous Xanthan gum (shear thinning, moderately elastic), and bovine blood. For steady flow conditions there was little difference at any measurement site in the wall shear rate levels measured for the four fluids. However, large differences were apparent for oscillatory flows, particularly at the inner curvature 180 degrees from the entrance of the curved artery model. At that position the peak wall shear rate for polyacrylamide was 5-6 times higher than for glycerin and 2-3 times higher than for bovine blood. It is concluded that polyacylamide is too elastic to provide a good model of blood flow under oscillatory conditions, particularly when there is wall shear reversal. Xanthan gum and glycerin are better analog fluids, but neither is entirely satisfactory.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2271763     DOI: 10.3233/bir-1990-27508

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  8 in total

1.  Pressure Measurements across Vascular Stenoses. Practice and Pitfalls.

Authors:  S G Imbesi; C W Kerber
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

2.  Endovascular Pressure Measurements: Validation with a Pulsatile Flow Model and Haemodynamic Assessment of Brain AVMs.

Authors:  M Forjaz Secca; P Vilela; J L Ferreira; F C Lopes; A Goulão
Journal:  Interv Neuroradiol       Date:  2005-02-08       Impact factor: 1.610

3.  Videographic assessment of the embolic characteristics of three polymeric compounds: ethylene vinyl alcohol, cellulose acetate, and liquid urethane.

Authors:  A M Norbash; R J Singer
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

4.  An experimental and angiographic explanation of why ulcerated carotid bulbs embolize.

Authors:  S G Imbesi; C W Kerber
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

5.  Flow dynamics in a lethal anterior communicating artery aneurysm.

Authors:  C W Kerber; S G Imbesi; K Knox
Journal:  AJNR Am J Neuroradiol       Date:  1999 Nov-Dec       Impact factor: 3.825

6.  Analysis of slipstream flow in a wide-necked basilar artery aneurysm: evaluation of potential treatment regimens.

Authors:  S G Imbesi; C W Kerber
Journal:  AJNR Am J Neuroradiol       Date:  2001-04       Impact factor: 3.825

7.  Aneurysmal pressure changes with nondetachable balloon placement and fluid infusion: rationale for liquid embolization.

Authors:  Steven G Imbesi; Kimberly Knox; Charles W Kerber
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

8.  Aneurysm flow dynamics: alterations of slipstream flow for neuroendovascular treatment with liquid embolic agents.

Authors:  Steven G Imbesi; Kimberly Knox; Charles W Kerber
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

  8 in total