Real-time ultrasound guided placement of temporary internal jugular vein catheters: assessment of technical success and complication rates in nephrology practice.

Hadim Akoglu1, Serhan Piskinpasa, Ezgi C Yenigun, Ramazan Ozturk, Fatih Dede, Ali R Odabas.   

Abstract

AIM: Internal jugular vein (IJV) catheterization is often required to gain access for haemodialysis. Use of ultrasound guidance has reduced the complication rates of this procedure. We hypothesized that nephrologists may perform IJV cannulation with a high technical success and low immediate complication rates under real-time ultrasound guidance.
METHODS: We prospectively analyzed 323 patients (186 male, 137 female) who underwent IJV cannulation with real-time ultrasound guidance. The number of needle punctures, technical success, the time between injection of local anaesthetic and entry into the IJV, and immediate complications were recorded. Patients with a history of multiple catheter insertions, previous difficulties during catheterization, poor compliance, obesity, impaired consciousness, skeletal deformity, disorder of haemostasis were regarded as high-risk group.
RESULTS: Cannulation of IJV was achieved in all patients. Of the 323 catheters, 125 (38.7%) were placed in high-risk patients. Average number of puncture was 1.26 (range, 1-4). IJV was entered on the first attempt in 261 (80.8%) patients. Only ten complications (10/323, 3.2%) developed; five (2.5%) in the normal-risk group, and five (4.0%) in the high-risk group. Cannulation of IJV took a longer time in the high-risk group than in the normal-risk group. The number of needle punctures, percent of successful cannulation on the first attempt, and the frequency of complications were similar between the high- and normal-risk groups.
CONCLUSIONS: Cannulation of IJV under real-time ultrasound guidance is very safe with high technical success rates. Nephrologists can use this technique with ease and with minimal complications in normal- and high-risk patients.
© 2012 The Authors. Nephrology © 2012 Asian Pacific Society of Nephrology.

Entities:  

Mesh:

Year:  2012        PMID: 22715902     DOI: 10.1111/j.1440-1797.2012.01637.x

Source DB:  PubMed          Journal:  Nephrology (Carlton)        ISSN: 1320-5358            Impact factor:   2.506


  3 in total

Review 1.  Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

Authors:  Golafsoun Ameri; John S H Baxter; Daniel Bainbridge; Terry M Peters; Elvis C S Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-08-31       Impact factor: 2.924

2.  Videothoracoscopic management of a perforated central vein and pleura after ultrasound-guided internal jugular vein cannulation: a case report.

Authors:  Jeong-Eun Kim; Joon-Pyo Jeon; Yongsuk Kim; Su Ah Jeong; Young-Eun Moon
Journal:  Korean J Anesthesiol       Date:  2014-04-28

3.  Towards a First-Person Perspective Mixed Reality Guidance System for Needle Interventions.

Authors:  Leah Groves; Natalie Li; Terry M Peters; Elvis C S Chen
Journal:  J Imaging       Date:  2022-01-07