Literature DB >> 22715092

Impact of mobile phase temperature on recovery and stability of monoclonal antibodies using recent reversed-phase stationary phases.

Szabolcs Fekete1, Serge Rudaz, Jean-Luc Veuthey, Davy Guillarme.   

Abstract

Recent reversed-phase wide-pore stationary phases were evaluated for the separation of intact monoclonal antibodies and their fragments. Two types of stationary phases were tested: Phenomenex Aeris Widepore, with 3.6 μm core-shell particles and Waters Acquity BEH300 with 1.7 μm fully porous particles. A systematic investigation was carried out using model IgG1 and IgG2 antibodies, namely rituximab, panitumumab, and bevacizumab. It appeared that adsorption of these antibodies on the stationary phase was significantly higher compared to proteins of equivalent size. The adsorption was particularly important for the intact antibodies of 150 kDa and for the largest fragments of 50 to 100 kDa (i.e., heavy chain, -fraction of antigene-binding). The present study demonstrated an obvious relationship between adsorption phenomenon and the unwanted strong secondary interactions (ionic and hydrogen bond) of the stationary phase. Thus, adsorption was more pronounced on the Aeris column because of the stronger ion exchange contribution of this stationary phase. Using C4 phase instead of C18 at 50-70°C, there is a slight reduction (5-20%) in adsorption. Two solutions were proposed to decrease the strength of secondary interactions and thus resolve (or at least diminish) adsorption issue. First, increasing mobile phase temperature up to 80-90°C appeared as a promising solution. However, temperature should be used with caution as it can partially damage large biomolecules. A compromise between residence time and temperature should be found. Second, it is recommended to add a small amount of an ancillary solvent, such as n-butanol to the mobile phase. Indeed, the hydroxyl group of n-butanol probably interacts with water adsorbed on the residual silanol groups "to shield" silanols.
© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22715092     DOI: 10.1002/jssc.201200297

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  3 in total

1.  Reversed-phase chromatography with large pore superficially porous particles for high throughput immunoglobulin G2 disulfide isoform separation.

Authors:  Bingchuan Wei; Bing Zhang; Barry Boyes; Yonghua Taylor Zhang
Journal:  J Chromatogr A       Date:  2017-10-18       Impact factor: 4.601

2.  Impact of temperature on optical sensing in biology based on investigation of SARS-CoV-2.

Authors:  Małgorzata Szczerska; Paweł Wityk; Paulina Listewnik
Journal:  J Biophotonics       Date:  2022-09-24       Impact factor: 3.390

3.  High sensitivity LC-MS profiling of antibody-drug conjugates with difluoroacetic acid ion pairing.

Authors:  Jennifer M Nguyen; Jacquelynn Smith; Susan Rzewuski; Cristina Legido-Quigley; Matthew A Lauber
Journal:  MAbs       Date:  2019-09-10       Impact factor: 5.857

  3 in total