Literature DB >> 22714782

Fully adiabatic 31P 2D-CSI with reduced chemical shift displacement error at 7 T--GOIA-1D-ISIS/2D-CSI.

M Chmelík1, I Just Kukurová, S Gruber, M Krššák, L Valkovič, S Trattnig, W Bogner.   

Abstract

A fully adiabatic phosphorus (31P) two-dimensional (2D) chemical shift spectroscopic imaging sequence with reduced chemical shift displacement error for 7 T, based on 1D-image-selected in vivo spectroscopy, combined with 2D-chemical shift spectroscopic imaging selection, was developed. Slice-selective excitation was achieved by a spatially selective broadband GOIA-W(16,4) inversion pulse with an interleaved subtraction scheme before nonselective adiabatic excitation, and followed by 2D phase encoding. The use of GOIA-W(16,4) pulses (bandwidth 4.3-21.6 kHz for 10-50 mm slices) reduced the chemical shift displacement error in the slice direction ∼1.5-7.7 fold, compared to conventional 2D-chemical shift spectroscopic imaging with Sinc3 selective pulses (2.8 kHz). This reduction was experimentally demonstrated with measurements of an MR spectroscopy localization phantom and with experimental evaluation of pulse profiles. In vivo experiments in clinically acceptable measurement times were demonstrated in the calf muscle (nominal voxel volume, 5.65 ml in 6 min 53 s), brain (10 ml, 6 min 32 s), and liver (8.33 ml, 8 min 14 s) of healthy volunteers at 7 T. High reproducibility was found in the calf muscle at 7 T. In combination with adiabatic excitation, this sequence is insensitive to the B1 inhomogeneities associated with surface coils. This sequence, which is termed GOIA-1D-ISIS/2D-CSI (goISICS), has the potential to be applied in both clinical research and in the clinical routine.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22714782     DOI: 10.1002/mrm.24363

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Advanced MR methods at ultra-high field (7 Tesla) for clinical musculoskeletal applications.

Authors:  Siegfried Trattnig; Stefan Zbýň; Benjamin Schmitt; Klaus Friedrich; Vladimir Juras; Pavol Szomolanyi; Wolfgang Bogner
Journal:  Eur Radiol       Date:  2012-06-12       Impact factor: 5.315

2.  (31)P CSI of the human brain in healthy subjects and tumor patients at 9.4 T with a three-layered multi-nuclear coil: initial results.

Authors:  Christian Mirkes; Gunamony Shajan; Grzegorz Chadzynski; Kai Buckenmaier; Benjamin Bender; Klaus Scheffler
Journal:  MAGMA       Date:  2016-01-25       Impact factor: 2.310

3.  Application of localized ³¹P MRS saturation transfer at 7 T for measurement of ATP metabolism in the liver: reproducibility and initial clinical application in patients with non-alcoholic fatty liver disease.

Authors:  Ladislav Valkovič; Martin Gajdošík; Stefan Traussnigg; Peter Wolf; Marek Chmelík; Christian Kienbacher; Wolfgang Bogner; Michael Krebs; Michael Trauner; Siegfried Trattnig; Martin Krššák
Journal:  Eur Radiol       Date:  2014-03-20       Impact factor: 5.315

4.  Dynamic 31 P-MRSI using spiral spectroscopic imaging can map mitochondrial capacity in muscles of the human calf during plantar flexion exercise at 7 T.

Authors:  Ladislav Valkovič; Marek Chmelík; Martin Meyerspeer; Borjan Gagoski; Christopher T Rodgers; Martin Krššák; Ovidiu C Andronesi; Siegfried Trattnig; Wolfgang Bogner
Journal:  NMR Biomed       Date:  2016-11-08       Impact factor: 4.044

Review 5.  In-vivo31P-MRS of skeletal muscle and liver: A way for non-invasive assessment of their metabolism.

Authors:  Ladislav Valkovič; Marek Chmelík; Martin Krššák
Journal:  Anal Biochem       Date:  2017-01-21       Impact factor: 3.365

6.  Ultra-high-field magnetic resonance spectroscopy in non-alcoholic fatty liver disease: Novel mechanistic and diagnostic insights of energy metabolism in non-alcoholic steatohepatitis and advanced fibrosis.

Authors:  Stefan Traussnigg; Christian Kienbacher; Martin Gajdošík; Ladislav Valkovič; Emina Halilbasic; Judith Stift; Christian Rechling; Harald Hofer; Petra Steindl-Munda; Peter Ferenci; Fritz Wrba; Siegfried Trattnig; Martin Krššák; Michael Trauner
Journal:  Liver Int       Date:  2017-05-20       Impact factor: 5.828

7.  Phosphorus MRS of healthy human spleen.

Authors:  Jan Weis; Maysam Jafar; Per Liss
Journal:  NMR Biomed       Date:  2022-06-15       Impact factor: 4.478

8.  Optimized (31)P MRS in the human brain at 7 T with a dedicated RF coil setup.

Authors:  Bart L van de Bank; Stephan Orzada; Frits Smits; Miriam W Lagemaat; Christopher T Rodgers; Andreas K Bitz; Tom W J Scheenen
Journal:  NMR Biomed       Date:  2015-10-07       Impact factor: 4.044

9.  Creatine kinase rate constant in the human heart at 7T with 1D-ISIS/2D CSI localization.

Authors:  Adil Bashir; Jianyi Zhang; Thomas S Denney
Journal:  PLoS One       Date:  2020-03-19       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.