Relative contributions of design, alignment, and loading variability in knee replacement mechanics.

Clare K Fitzpatrick1, Chadd W Clary, Peter J Laz, Paul J Rullkoetter.   

Abstract

Substantial variation in total knee replacement (TKR) outcomes exists within the patient population. Some of this variability is due to differences in the design of the implanted components and variation in surgical alignment, while other variability is due to differences in the applied forces and torques due to anatomic and physiological differences within a patient population. We evaluated the relative contributions of implant design, surgical alignment, and patient-specific loading variability to overall tibiofemoral joint mechanics to provide insight into which measures can be influenced through design and surgical decisions, and which are inherently dependent on variation within the patient population and should be considered in the robustness of the implant design and surgical procedure. Design, surgical, and loading parameters were assessed using probabilistic finite element methods during simulated stance-phase gait and squat activities. Patient-specific loading was found to be the primary contributor to joint loading and kinematics during low flexion, particularly under conditions of high external loads (for instance, the gait cycle with high internal-external torque), while design and surgical factors, particularly femoral posterior radius and posterior slope of the tibial insert became increasingly important in TKR performance in deeper flexion.
Copyright © 2012 Orthopaedic Research Society.

Entities:  

Mesh:

Year:  2012        PMID: 22696429     DOI: 10.1002/jor.22169

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  8 in total

1.  [Individualized total knee arthroplasty].

Authors:  A F Steinert; L Sefrin; M Hoberg; J Arnholdt; M Rudert
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

2.  A probabilistic approach to quantify the impact of uncertainty propagation in musculoskeletal simulations.

Authors:  Casey A Myers; Peter J Laz; Kevin B Shelburne; Bradley S Davidson
Journal:  Ann Biomed Eng       Date:  2014-11-18       Impact factor: 3.934

3.  Subject-specific modeling of muscle force and knee contact in total knee arthroplasty.

Authors:  Alessandro Navacchia; Paul J Rullkoetter; Pascal Schütz; Renate B List; Clare K Fitzpatrick; Kevin B Shelburne
Journal:  J Orthop Res       Date:  2016-02-04       Impact factor: 3.494

Review 4.  [Total knee arthroplasty. Patient-specific instruments and implants].

Authors:  Andre F Steinert; Boris M Holzapfel; Lukas Sefrin; Jörg Arnholdt; Maik Hoberg; Maximilian Rudert
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

5.  New design total knee arthroplasty shows medial pivoting movement under weight-bearing conditions.

Authors:  Laura Bragonzoni; Giulio Maria Marcheggiani Muccioli; Marco Bontempi; Tommaso Roberti di Sarsina; Umberto Cardinale; Domenico Alesi; Francesco Iacono; Maria Pia Neri; Stefano Zaffagnini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-27       Impact factor: 4.342

Review 6.  Analysis of Uncertainty and Variability in Finite Element Computational Models for Biomedical Engineering: Characterization and Propagation.

Authors:  Nerea Mangado; Gemma Piella; Jérôme Noailly; Jordi Pons-Prats; Miguel Ángel González Ballester
Journal:  Front Bioeng Biotechnol       Date:  2016-11-07

7.  Influence of conformity on the wear of total knee replacement: An experimental study.

Authors:  Claire L Brockett; Silvia Carbone; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2017-12-17       Impact factor: 1.617

8.  A randomized controlled trial comparing functional outcomes for navigated kinematically aligned total knee arthroplasty versus navigated mechanically aligned total knee arthroplasty : the MaKKRO trial.

Authors:  Vilas Narayan Sadekar; Sandeep Datir; Victoria Allgar; Hemant Sharma
Journal:  Bone Jt Open       Date:  2021-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.