Literature DB >> 30368560

New design total knee arthroplasty shows medial pivoting movement under weight-bearing conditions.

Laura Bragonzoni1, Giulio Maria Marcheggiani Muccioli2,3, Marco Bontempi1, Tommaso Roberti di Sarsina4, Umberto Cardinale1, Domenico Alesi4, Francesco Iacono5, Maria Pia Neri4, Stefano Zaffagnini4.   

Abstract

PURPOSE: To assess, using model-based dynamic radiostereometric analysis (RSA), the biomechanical behaviour of a new design posterior-stabilized (PS) fixed-bearing (FB) total knee arthroplasty (TKA) in vivo while patients performing two common motor tasks. The hypothesis was that model-based dynamic RSA is able to detect different behaviour of the implant under weight-bearing and non-weight-bearing conditions.
METHODS: A cohort of 15 non-consecutive patients was evaluated by dynamic RSA 9 months after TKA implantation. The mean age of patients was 73.4 (65-72) years. The kinematic evaluations were performed using an RSA device (BI-STAND DRX 2) developed in our Institute. The patients were asked to perform two active motor tasks: sit-to-stand in weight-bearing condition; range of motion (ROM) while sitting on the chair. The motion parameters were evaluated using the Grood and Suntay decomposition and the low-point kinematics methods.
RESULTS: The dynamic RSA evaluation showed a significant difference (p < 0.05) between the biomechanical behaviour of the prosthesis during the two motor tasks. When subjected to the patient weight (in the sit-to-stand) the low point of the medial compartment had a shorter motion (5.7 ± 0.2 mm) than the lateral (11.0 ± 0.2 mm). This realizes a medial pivot motion as in the normal knee. In the ROM task, where the patient had no weight on the prosthesis, this difference was not present: the medial compartment had a displacement of 12.7 ± 0.2 mm, while the lateral had 17.3 ± 0.2 mm.
CONCLUSIONS: Model-based RSA proved to be an effective tool for the evaluation of TKA biomechanics. In particular, it was able to determine that the fixed-bearing posterior-stabilized TKA design evaluated in this study showed a medial pivoting movement under weight-bearing conditions that was not present when load was not applied. Under loading conditions what drives the pattern of movement is the prosthetic design itself. By the systematic use of this study protocol future comparisons among different implants could be performed, thus contributing significantly to the improvement of TKA design. LEVEL OF EVIDENCE: IV.

Entities:  

Keywords:  Dynamic radiostereometric analysis; In vivo knee kinematics; Total knee arthroplasty

Mesh:

Year:  2018        PMID: 30368560     DOI: 10.1007/s00167-018-5243-5

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  29 in total

1.  Tibiofemoral movement 3: full flexion in the living knee studied by MRI.

Authors:  S Nakagawa; Y Kadoya; S Todo; A Kobayashi; H Sakamoto; M A Freeman; Y Yamano
Journal:  J Bone Joint Surg Br       Date:  2000-11

2.  Cruciate-retaining and cruciate-substituting total knee arthroplasty: an in vitro comparison of the kinematics under muscle loads.

Authors:  G Li; S Zayontz; E Most; E Otterberg; K Sabbag; H E Rubash
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

3.  Multicenter determination of in vivo kinematics after total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz; Brian D Haas; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

Review 4.  The movement of the knee studied by magnetic resonance imaging.

Authors:  M A R Freeman; V Pinskerova
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

5.  In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

Authors:  Douglas A Dennis; Mohamed R Mahfouz; Richard D Komistek; William Hoff
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

Review 6.  The movement of the normal tibio-femoral joint.

Authors:  M A R Freeman; V Pinskerova
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

7.  Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee.

Authors:  H Iwaki; V Pinskerova; M A Freeman
Journal:  J Bone Joint Surg Br       Date:  2000-11

8.  Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using 'interventional' MRI.

Authors:  P Johal; A Williams; P Wragg; D Hunt; W Gedroyc
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

9.  In vivo fluoroscopic analysis of the normal human knee.

Authors:  Richard D Komistek; Douglas A Dennis; Mohamed Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

10.  Functional comparison of posterior cruciate-retaining versus posterior stabilized total knee arthroplasty.

Authors:  Shigeki Maruyama; Shinichi Yoshiya; Nobuzo Matsui; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  J Arthroplasty       Date:  2004-04       Impact factor: 4.757

View more
  3 in total

Review 1.  Sensor-Assisted Total Knee Arthroplasty: A Narrative Review.

Authors:  Cheol Hee Park; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2021-02-15

2.  Knee position at the moment of bone bruise could reflect the late phase of non-contact anterior cruciate ligament injury rather than the mechanisms leading to ligament failure.

Authors:  Alberto Grassi; Piero Agostinone; Stefano Di Paolo; Gian Andrea Lucidi; Luca Macchiarola; Marco Bontempi; Gregorio Marchiori; Laura Bragonzoni; Stefano Zaffagnini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-03-03       Impact factor: 4.342

3.  Over-constrained kinematic of the medial compartment leads to lower clinical outcomes after total knee arthroplasty.

Authors:  Nicola Pizza; Stefano Di Paolo; Raffaele Zinno; Giulio Maria Marcheggiani Muccioli; Piero Agostinone; Domenico Alesi; Marco Bontempi; Stefano Zaffagnini; Laura Bragonzoni
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-01-02       Impact factor: 4.114

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.