Biomechanical evaluation of fractured tibia externally fixed with an LCP.

Chaosuan Kanchanomai1, Vajara Phiphobmongkol.   

Abstract

A locking compression plate (LCP) can serve as an external fixation for fractured tibia. However, there is concern about the stability and endurance during partial weight bearing. This study was experimentally evaluated the effects of fracture gap sizes (1, 5, and 10 mm) on the stability and endurance of fractured tibia externally fixed with a 316L-stainless LCP. For stable fractured tibia (1-mm fracture gap), the large contact area of fracture surfaces resulted in nearly similar stiffness to that of intact tibia. The partial weight bearing is therefore possible. Whereas smaller contact area and no contact of fracture surfaces were observed for tibias with 5-mm and 10-mm fracture gaps, respectively. Their stiffnesses were significantly lower than those of intact tibia and tibia with 1-mm fracture gap. Thus, the partial weight bearing should be considered carefully in early phase of treatment. All LCP-tibial models were cyclically loaded beyond 500,000 cycles, that is, approximately 6 months of healing, without any failure of LCP. Thus, the failure of LCP is unlikely a critical issue for the present cases.

Entities:  

Mesh:

Year:  2012        PMID: 22695341     DOI: 10.1123/jab.28.5.587

Source DB:  PubMed          Journal:  J Appl Biomech        ISSN: 1065-8483            Impact factor:   1.833


  7 in total

1.  The Utility of Supracutaneous Plating in the Staged Management of Compound Distal Femur Fracture: A Case Report.

Authors:  Aditya L Kekatpure; Khizar K Khan; Aashay L Kekatpure
Journal:  Cureus       Date:  2022-05-02

2.  Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture.

Authors:  Norachart Sirisreetreerux; Paphon Sa-Ngasoongsong; Pongsthorn Chanplakorn; Noratep Kulachote; Sukij Laohajaroensombat; Chanyut Suphachatwong; Vajara Phiphobmongkol; Wiwat Wajanavisit
Journal:  Orthop Rev (Pavia)       Date:  2013-06-07

3.  A locking compression plate as an external fixator for treating infected nonunion of the humeral diaphysis.

Authors:  Cong Xiao; Fan Tang; Yong Zhou; Wenli Zhang; Yi Luo; Hong Duan; Chongqi Tu
Journal:  BMC Surg       Date:  2016-08-05       Impact factor: 2.102

4.  Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness.

Authors:  B F H Ang; J Y Chen; A K S Yew; S K Chua; S M Chou; S L Chia; J S B Koh; T S Howe
Journal:  Bone Joint Res       Date:  2017-04       Impact factor: 5.853

5.  Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study.

Authors:  Wei Liu; Lihui Yang; Xiaochuan Kong; Likun An; Gang Hong; Zicheng Guo; Lei Zang
Journal:  BMC Musculoskelet Disord       Date:  2017-01-19       Impact factor: 2.362

6.  Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis.

Authors:  Dejan Blažević; Janoš Kodvanj; Petra Adamović; Dinko Vidović; Zlatko Trobonjača; Srećko Sabalić
Journal:  J Orthop Surg Res       Date:  2022-01-11       Impact factor: 2.359

Review 7.  Locked plating as an external fixator in treating tibial fractures: A PRISMA-compliant systematic review.

Authors:  Peng Luo; Ding Xu; Jia Wu; Yi-Heng Chen
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.