Literature DB >> 22692864

Dual-window dual-bandwidth spectroscopic optical coherence tomography metric for qualitative scatterer size differentiation in tissues.

Benjamin Chia-Meng Tay1, Tzu-Hao Chow, Beng-Koon Ng, Thomas Kwok-Seng Loh.   

Abstract

This study investigates the autocorrelation bandwidths of dual-window (DW) optical coherence tomography (OCT) k-space scattering profile of different-sized microspheres and their correlation to scatterer size. A dual-bandwidth spectroscopic metric defined as the ratio of the 10% to 90% autocorrelation bandwidths is found to change monotonically with microsphere size and gives the best contrast enhancement for scatterer size differentiation in the resulting spectroscopic image. A simulation model supports the experimental results and revealed a tradeoff between the smallest detectable scatterer size and the maximum scatterer size in the linear range of the dual-window dual-bandwidth (DWDB) metric, which depends on the choice of the light source optical bandwidth. Spectroscopic OCT (SOCT) images of microspheres and tonsil tissue samples based on the proposed DWDB metric showed clear differentiation between different-sized scatterers as compared to those derived from conventional short-time Fourier transform metrics. The DWDB metric significantly improves the contrast in SOCT imaging and can aid the visualization and identification of dissimilar scatterer size in a sample. Potential applications include the early detection of cell nuclear changes in tissue carcinogenesis, the monitoring of healing tendons, and cell proliferation in tissue scaffolds.

Entities:  

Mesh:

Year:  2012        PMID: 22692864     DOI: 10.1109/TBME.2012.2202391

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

1.  Correlation of the derivative as a robust estimator of scatterer size in optical coherence tomography (OCT).

Authors:  M Kassinopoulos; E Bousi; I Zouvani; C Pitris
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

2.  Comparison of different metrics for analysis and visualization in spectroscopic optical coherence tomography.

Authors:  Volker Jaedicke; Semih Agcaer; Francisco E Robles; Marian Steinert; David Jones; Sebastian Goebel; Nils C Gerhardt; Hubert Welp; Martin R Hofmann
Journal:  Biomed Opt Express       Date:  2013-11-22       Impact factor: 3.732

3.  Molecular Imaging in Optical Coherence Tomography.

Authors:  Scott P Mattison; Wihan Kim; Jesung Park; Brian E Applegate
Journal:  Curr Mol Imaging       Date:  2014-07-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.