Literature DB >> 22691157

In vitro assessment of primary stability of Straumann® implant designs.

Georgios E Romanos1, Gabriela Ciornei, Adina Jucan, Hans Malmstrom, Bhumija Gupta.   

Abstract

BACKGROUND: Primary implant stability (PS) is one of the main factors influencing implant survival rate. Several methods to determine the PS have been used, such as Periotest values (PVs) and resonance frequency analysis (RFA) with implant stability quotient (ISQ) values.
PURPOSE: The aim of this study was to compare different implant designs in regard to PS assessed by Periotest and RFA in vitro.
MATERIALS AND METHODS: A total of 90 implants were placed in freshly slaughtered cow ribs. The implants (Straumann®, Institute Straumann AG, Basel, Switzerland; length 10 mm, ø3.3 mm) had the following three designs: Bone Level (BL, 30 implants), Standard Plus (SP, 30 implants), and Tapered Effect (TE, 30 implants). Before implant placement, the investigator was calibrated for every design according to the manufacturer's instructions. An independent observer, blinded to the study, assessed the accuracy of placement. RFA based on the Osstell device and PVs were performed after abutment connection. One-way analysis of variance and Tukey's post hoc test were used for statistical evaluation.
RESULTS: All implants were mechanically stable. The mean PV for BL was -4.67(± 1.18), for SP, -6.07(± 0.94), and for TE, -6.57(± 0.57). The mean ISQ values were 75.02(± 3.65), 75.98(± 3.00), and 79.83(± 1.85), respectively. The one-way ANOVA showed significant difference among three implant designs in PV (p < .0001) and for the ISQ between BL/TE or SP/TE implants (p < .0001). In addition, the Tukey's (pair-wise comparison) test showed significant differences in PV and RFA between the BL/T (p < .0001).
CONCLUSION: Within the limitations of this study, higher implant stability was found for tapered designed implants.
© 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  Osstell; Periotest; implant design; primary stability

Mesh:

Year:  2012        PMID: 22691157     DOI: 10.1111/j.1708-8208.2012.00464.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  8 in total

1.  A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants: a preliminary study for simultaneous vertical ridge augmentation.

Authors:  Daisuke Ueno; Kei Nakamura; Kousuke Kojima; Takeshi Toyoshima; Hideaki Tanaka; Kazuhiko Ueda; Kiyoshi Koyano; Toshiro Kodama
Journal:  Odontology       Date:  2017-08-02       Impact factor: 2.634

2.  Effect of implant design on primary stability using torque-time curves in artificial bone.

Authors:  Yoko Yamaguchi; Makoto Shiota; Motohiro Munakata; Shohei Kasugai; Masahiko Ozeki
Journal:  Int J Implant Dent       Date:  2015-08-08

3.  Implant Stability of Biological Hydroxyapatites Used in Dentistry.

Authors:  Maria Piedad Ramírez Fernández; Sergio A Gehrke; Patricia Mazón; Jose L Calvo-Guirado; Piedad N De Aza
Journal:  Materials (Basel)       Date:  2017-06-12       Impact factor: 3.623

4.  In vitro comparison of primary stability of two implant designs in D3 bone.

Authors:  J González-Serrano; R Ortega-Aranegui; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01

5.  Repeatability of the resonance frequency analysis values in implants with a new technology.

Authors:  M-C Díaz-Castro; A Falcao; P López-Jarana; C Falcao; J-V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

6.  Relevant Design Aspects to Improve the Stability of Titanium Dental Implants.

Authors:  M Herrero-Climent; P López-Jarana; B F Lemos; F J Gil; C Falcão; J V Ríos-Santos; B Ríos-Carrasco
Journal:  Materials (Basel)       Date:  2020-04-18       Impact factor: 3.623

7.  Primary stability of different implant macrodesigns in a sinus floor elevation simulated model: an ex vivo study.

Authors:  Mikio Imai; Yoichiro Ogino; Hideaki Tanaka; Kiyoshi Koyano; Yasunori Ayukawa; Takeshi Toyoshima
Journal:  BMC Oral Health       Date:  2022-08-08       Impact factor: 3.747

8.  Effect of implant macro-design on primary stability: A prospective clinical study.

Authors:  Naroa Lozano-Carrascal; Oscar Salomó-Coll; Marta Gilabert-Cerdà; Nuria Farré-Pagés; Jordi Gargallo-Albiol; Federico Hernández-Alfaro
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-03-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.