Literature DB >> 22684406

Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study.

Philippe Thelen1, Cyrille Delin, Dominique Folinais, Catherine Radier.   

Abstract

OBJECTIVE: Knee coronal alignment is routinely assessed on a full-length radiograph of the lower limbs. However, poor positioning of the knee during the procedure affects the accuracy of this kind of measurement, particularly in cases combining knee rotation and flexion. The purpose of this study was to assess the value of a three-dimensional assessment of the hip-knee-ankle (HKA) angle based on a biplanar radiographic system.
MATERIALS AND METHODS: A biplanar slot scanning system was used to take radiographs of three lower-limb synthetic models with similar frontal deviation (5° valgus) but different flexion angulations (0°, 9°, and 18°). Biplane acquisitions were done with lower-limb axial rotations ranging from 20° of internal rotation to 20° of external rotation on each of the lower limb models. Three independent observers performed standard 2D measurements of the HKA angle from each anteroposterior (AP) image and also modeled the lower limb in 3D for each biplane acquisition with dedicated software. The HKA angle was automatically calculated from the 3D models. The results of the 2D and 3D techniques were compared.
RESULTS: Axial rotation provoked 2D HKA measurement errors up to, respectively, 1.4°, 4.7°, and 6.8° for the lower extremities with 0°, 9°, and 18° flexion, while it never affected the 3D HKA measurement for more than 1.5°. Interobserver errors were 0.7° (SD = 0.5°) for the 2D measurements and 0.6° (SD = 0.4°) for the 3D measurements.
CONCLUSIONS: The 3D modeling allows for a more accurate evaluation of coronal alignment compared to 2D, eliminating bias due to wrong knee positioning.

Entities:  

Mesh:

Year:  2012        PMID: 22684406     DOI: 10.1007/s00256-012-1438-x

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  22 in total

1.  Three-dimensional lower extremity alignment assessment system: application to evaluation of component position after total knee arthroplasty.

Authors:  Takashi Sato; Yoshio Koga; Go Omori
Journal:  J Arthroplasty       Date:  2004-08       Impact factor: 4.757

2.  The role of knee alignment in disease progression and functional decline in knee osteoarthritis.

Authors:  L Sharma; J Song; D T Felson; S Cahue; E Shamiyeh; D D Dunlop
Journal:  JAMA       Date:  2001-07-11       Impact factor: 56.272

3.  Quantitative 3-dimensional analysis of preoperative and postoperative joint lines in total knee arthroplasty: a new concept for evaluation of component alignment.

Authors:  Takashi Sato; Yoshio Koga; Ten Sobue; Go Omori; Yuji Tanabe; Makoto Sakamoto
Journal:  J Arthroplasty       Date:  2007-04-20       Impact factor: 4.757

4.  A quantitative approach to radiography of the lower limb. Principles and applications.

Authors:  T D Cooke; R A Scudamore; J T Bryant; C Sorbie; D Siu; B Fisher
Journal:  J Bone Joint Surg Br       Date:  1991-09

5.  Frontal plane knee alignment: a call for standardized measurement.

Authors:  T Derek V Cooke; Elizabeth A Sled; R Allan Scudamore
Journal:  J Rheumatol       Date:  2007-09       Impact factor: 4.666

6.  Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays.

Authors:  Y Chaibi; T Cresson; B Aubert; J Hausselle; P Neyret; O Hauger; J A de Guise; W Skalli
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-05-24       Impact factor: 1.763

7.  Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager.

Authors:  Sylvain Deschênes; Guy Charron; Gilles Beaudoin; Hubert Labelle; Josée Dubois; Marie-Claude Miron; Stefan Parent
Journal:  Spine (Phila Pa 1976)       Date:  2010-04-20       Impact factor: 3.468

8.  Three-dimensional lower extremity alignment in the weight-bearing standing position in healthy elderly subjects.

Authors:  Akihiro Ariumi; Takashi Sato; Koichi Kobayashi; Yoshio Koga; Go Omori; Izumi Minato; Naoto Endo
Journal:  J Orthop Sci       Date:  2010-02-12       Impact factor: 1.601

9.  Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program.

Authors:  Elizabeth A Sled; Lisa M Sheehy; David T Felson; Patrick A Costigan; Miu Lam; T Derek V Cooke
Journal:  Rheumatol Int       Date:  2009-11-01       Impact factor: 2.631

10.  Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs.

Authors:  J Sailer; M Scharitzer; P Peloschek; A Giurea; H Imhof; S Grampp
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315

View more
  22 in total

1.  Assessment of two-dimensional (2D) and three-dimensional (3D) lower limb measurements in adults: Comparison of micro-dose and low-dose biplanar radiographs.

Authors:  Andrea B Rosskopf; Christian W A Pfirrmann; Florian M Buck
Journal:  Eur Radiol       Date:  2016-01-06       Impact factor: 5.315

2.  Three-dimensional quantitative analysis of the proximal femur and the pelvis in children and adolescents using an upright biplanar slot-scanning X-ray system.

Authors:  Kinga Szuper; Ádám Tibor Schlégl; Eleonóra Leidecker; Csaba Vermes; Szabolcs Somoskeöy; Péter Than
Journal:  Pediatr Radiol       Date:  2014-08-26

3.  Presence of rotational errors in long leg radiographs after total knee arthroplasty and impact on measured lower limb and component alignment.

Authors:  Günther Maderbacher; Clemens Baier; Achim Benditz; Ferdinand Wagner; Felix Greimel; Joachim Grifka; Armin Keshmiri
Journal:  Int Orthop       Date:  2017-01-31       Impact factor: 3.075

4.  Design and validation of automated femoral bone morphology measurements in cerebral palsy.

Authors:  Noyeol Park; Jehee Lee; Ki Hyuk Sung; Moon Seok Park; Seungbum Koo
Journal:  J Digit Imaging       Date:  2014-04       Impact factor: 4.056

5.  Three dimensional radiological imaging of normal lower-limb alignment in children.

Authors:  Ádám Tibor Schlégl; Kinga Szuper; Szabolcs Somoskeöy; Péter Than
Journal:  Int Orthop       Date:  2015-07-10       Impact factor: 3.075

6.  Femoral and tibial torsion measurements in children and adolescents: comparison of MRI and 3D models based on low-dose biplanar radiographs.

Authors:  Andrea B Rosskopf; Florian M Buck; Christian W A Pfirrmann; Leonhard E Ramseier
Journal:  Skeletal Radiol       Date:  2017-02-03       Impact factor: 2.199

7.  Handheld Navigation Device and Patient-Specific Cutting Guides Result in Similar Coronal Alignment for Primary Total Knee Arthroplasty: a Retrospective Matched Cohort Study.

Authors:  Michael E Steinhaus; Alexander S McLawhorn; Shawn S Richardson; Patrick Maher; David J Mayman
Journal:  HSS J       Date:  2016-02-29

8.  Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?

Authors:  Jean Yves Lazennec; Quentin Chometon; Dominique Folinais; Christopher B Robbins; Aidin Eslam Pour
Journal:  Int Orthop       Date:  2016-11-14       Impact factor: 3.075

9.  No impact of under-correction and joint line obliquity on clinical outcomes of total knee arthroplasty for the varus knee.

Authors:  Richard D Rames; Michael Mathison; Zachary Meyer; Robert L Barrack; Denis Nam
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-15       Impact factor: 4.342

10.  Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

Authors:  Tobias J Dietrich; Christian W A Pfirrmann; Alexander Schwab; Katja Pankalla; Florian M Buck
Journal:  Skeletal Radiol       Date:  2013-03-28       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.