Literature DB >> 2267619

Clinical study on stability of combined distraction and compression rod instrumentation with posterolateral fusion for unstable degenerative spondylolisthesis.

M Fujiya1, M Saita, K Kaneda, K Abumi.   

Abstract

The authors examined the stability of combined distraction and compression rod instrumentation with posterolateral fusion in 40 consecutive patients with unstable degenerative spondylolisthesis. All operations were performed by floating fusion of L3-4 or L4-5 after decompression procedures. Mobility at the fused level was checked every 4 weeks after operation by the disc space angle on the functional radiographic films without brace. The average period of postoperative follow-up was 26 months. In 30 patients, no mobility was found at any time. In six patients, any mobility disappeared within 24 weeks, and in three patients, within 1 year. Pseudoarthrosis was found in one patient. The solid fusion rate was 97.5%. The values of percent slippage and slip angle were slightly improved. Lumbar lordosis was in the normal range at follow-up.

Entities:  

Mesh:

Year:  1990        PMID: 2267619     DOI: 10.1097/00007632-199011010-00023

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  7 in total

1.  A meta-analysis of artificial total disc replacement versus fusion for lumbar degenerative disc disease.

Authors:  Wu Yajun; Zhu Yue; Han Xiuxin; Cui Cui
Journal:  Eur Spine J       Date:  2010-04-04       Impact factor: 3.134

2.  Reduction of lumbar spondylolisthesis using a CDI pedicle screw system.

Authors:  Y Aota; K Kumano; S Hirabayashi; Y Ogawa
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

Review 3.  Pedicle screw fixation in spinal disorders: a European view.

Authors:  N Boos; J K Webb
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

4.  Predictors of outcomes after posterior decompression and fusion in degenerative spondylolisthesis.

Authors:  Marc-Antoine Rousseau; Jean-Yves Lazennec; Elisa C Bass; Gérard Saillant
Journal:  Eur Spine J       Date:  2004-06-10       Impact factor: 3.134

5.  Comparative Clinical Effectiveness and Safety of Bone Morphogenetic Protein Versus Autologous Iliac Crest Bone Graft in Lumbar Fusion: A Meta-analysis and Systematic Review.

Authors:  Shichao Liu; Yinqing Wang; Zeyan Liang; Maochao Zhou; Chunmei Chen
Journal:  Spine (Phila Pa 1976)       Date:  2020-06-15       Impact factor: 3.241

6.  Lever reduction using polyaxial screw and rod fixation system for the treatment of degenerative lumbar spondylolisthesis with spinal stenosis: technique and clinical outcome.

Authors:  Zu-De Liu; Xin-Feng Li; Lie Qian; Lian-Ming Wu; Li-Feng Lao; Han-Tao Wang
Journal:  J Orthop Surg Res       Date:  2015-02-15       Impact factor: 2.359

7.  Total Disc Replacement Versus Anterior-Posterior Interbody Fusion in the Lumbar Spine and Lumbosacral Junction: A Cost Analysis.

Authors:  Timo Stubig; Malik Ahmed; Amir Ghasemi; Luigi Aurelio Nasto; Michael Grevitt
Journal:  Global Spine J       Date:  2017-07-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.