Literature DB >> 22672713

Clinical and radiological outcomes of two implants with different prosthetic interfaces and neck configurations: randomized, controlled, split-mouth clinical trial.

Alessandro Pozzi1, Enrico Agliardi, Marco Tallarico, Alberto Barlattani.   

Abstract

BACKGROUND: Peri-implant bone loss seems to occur following implant placement/loading regardless of all the efforts to eliminate it. Several factors, including surgical trauma, biologic width establishment, lack of passive fit of the superstructures, implant-abutment microgap, and occlusal overloading, may increase peri-implant bone loss. Over the years, new interface designs were introduced and clinical studies suggest that internal conical connection and platform shifting may be advantageous for marginal bone preservation.
PURPOSE: To compare clinical and radiological outcomes of two implant designs with different prosthetic interfaces and neck configurations in a randomized, controlled, split-mouth clinical trial.
MATERIALS AND METHODS: Thirty-four partially edentate patients randomly received at least one internal conical connection with back-tapered collar and platform shifting design or external-hexagon implants with flat-to-flat implant-abutment interface. Primary end point was peri-implant bone level changes at different time points, failures of implants and/or prosthesis, any complications, implant stability quotient (ISQ) values, and periodontal parameters.
RESULTS: No dropout occurred. Marginal bone changes were statistically significantly different with better results for the internal conical connection. No implants and prosthesis failures have been observed, yielding a cumulative survival rate of 100%. A high ISQ value was found for both implants, and no statistically significant difference was found for ISQ mean values between interventions at each time point (p > .05). All implants showed no bleeding on probing and a very slight amount of plaque at the 1-year-in-function visit.
CONCLUSIONS: Both implant designs investigated performed similarly in terms of failure rates, providing successful results up to 1 year after loading. The back-tapered neck configuration with conical connection and built-in platform shifting showed statistically lower marginal bone loss than straight neck configuration with flat-to-flat implant-abutment interface and external-hexagonal connection.
© 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  bone level; bone loss; dental implants; implant-abutment interface; platform shifting

Mesh:

Year:  2012        PMID: 22672713     DOI: 10.1111/j.1708-8208.2012.00465.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  11 in total

Review 1.  Bone level changes around platform switching and platform matching implants: a systematic review with meta-analysis.

Authors:  M DI Girolamo; R Calcaterra; R DI Gianfilippo; C Arcuri; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

Review 2.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

3.  Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study.

Authors:  Frederico Santos Lages; Dhelfeson Willya Douglas-de-Oliveira; Guilherme Siqueira Ibelli; Fatimah Assaf; Thallita Pereira Queiroz; Fernando Oliveira Costa
Journal:  PLoS One       Date:  2017-07-24       Impact factor: 3.240

Review 4.  Survival and Success Rates of Different Shoulder Designs: A Systematic Review of the Literature.

Authors:  Marco Tallarico; Marco Caneva; Silvio Mario Meloni; Erta Xhanari; Yuki Omori; Luigi Canullo
Journal:  Int J Dent       Date:  2018-04-26

5.  Peri-Implant Bone Resorption during Healing Abutment Placement: The Effect of a 0.20% Chlorhexidine Gel vs. Placebo-A Randomized Double Blind Controlled Human Study.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Ilaria De Tullio; Tonino Traini; Sergio Caputi
Journal:  Biomed Res Int       Date:  2018-10-16       Impact factor: 3.411

6.  Single-Crown, Short and Ultra-Short Implants, in Association with Simultaneous Internal Sinus Lift in the Atrophic Posterior Maxilla: A Three-Year Retrospective Study.

Authors:  Giorgio Lombardo; Mauro Marincola; Annarita Signoriello; Giovanni Corrocher; Pier Francesco Nocini
Journal:  Materials (Basel)       Date:  2020-05-11       Impact factor: 3.623

Review 7.  Implant-abutment emergence angle and profile in relation to peri-implantitis: A systematic review.

Authors:  Sara Soulami; Dagmar E Slot; Fridus van der Weijden
Journal:  Clin Exp Dent Res       Date:  2022-06-17

8.  Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis.

Authors:  Cleidiel Aparecido Araujo Lemos; Fellippo Ramos Verri; Joel Ferreira Santiago Junior; Victor Eduardo de Souza Batista; Daniel Takanori Kemmoku; Pedro Yoshito Noritomi; Eduardo Piza Pellizzer
Journal:  J Healthc Eng       Date:  2018-09-03       Impact factor: 2.682

9.  Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review.

Authors:  Saverio Cosola; Simone Marconcini; Michela Boccuzzi; Giovanni Battista Menchini Fabris; Ugo Covani; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Int J Environ Res Public Health       Date:  2020-09-22       Impact factor: 3.390

10.  Comparison between Early Loaded Single Implants with Internal Conical Connection or Implants with Transmucosal Neck Design: A Non-Randomized Controlled Trial with 1-Year Clinical, Aesthetics, and Radiographic Evaluation.

Authors:  Francesco Mattia Ceruso; Irene Ieria; Marco Tallarico; Silvio Mario Meloni; Aurea Immacolata Lumbau; Alessandro Mastroianni; Alessio Zotti; Marco Gargari
Journal:  Materials (Basel)       Date:  2022-01-10       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.