Literature DB >> 22659269

Transcatheter valve implantation: damage to the human aorta after valved stent delivery system exposure--an in vitro study.

Paul Philipp Heinisch1, Oliver Richter, Michael Schünke, Rene Bombien Quaden.   

Abstract

Transcatheter heart valve implantation can be performed transapically and transfemorally. The transfemoral way to the aortic valve is significantly longer than the transapical one. The aim of this study was to analyse the intima of 15 human aortas after the deployment of different conventional valved stent delivery systems. Fifteen human aortas have been analysed (77 ± 8.4 years). These aortas were preserved with formalin and explanted from the common iliac arteries to the ascending aorta. After protocolling all relevant vascular parameters, the deployment force of different conventional valved stent delivery systems was analysed. After that, the intima was closely investigated by endoscopy. The deployment force of the old catheter was not different from the actual system. The endoscopic investigation revealed significant intimal damages in all parts of the aorta after deployment of the delivery system. This study demonstrated that the passage to the aortic valve can result in significant intimal damage regardless of the used deployment catheter. Efforts are necessary to lower the profile of the deployment devices to increase their flexibility. The intima of the aorta and possible damage have to get back into the physicians' focus to avoid possible late aortic complications.

Entities:  

Mesh:

Year:  2012        PMID: 22659269      PMCID: PMC3422938          DOI: 10.1093/icvts/ivs225

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  15 in total

1.  Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry.

Authors:  Hélène Eltchaninoff; Alain Prat; Martine Gilard; Alain Leguerrier; Didier Blanchard; Gérard Fournial; Bernard Iung; Patrick Donzeau-Gouge; Christophe Tribouilloy; Jean-Louis Debrux; Alain Pavie; Pascal Gueret
Journal:  Eur Heart J       Date:  2010-09-15       Impact factor: 29.983

2.  A new transcatheter aortic valve and percutaneous valve delivery system.

Authors:  John G Webb; Lukas Altwegg; Jean-Bernard Masson; Saad Al Bugami; Abdullah Al Ali; Robert A Boone
Journal:  J Am Coll Cardiol       Date:  2009-05-19       Impact factor: 24.094

3.  Percutaneous aortic valve replacement: computed tomography scan after valved stent implantation in human cadaver hearts.

Authors:  René Bombien; Tim Hümme; Michael Schünke; Georg Lutter
Journal:  Eur J Cardiothorac Surg       Date:  2009-07-15       Impact factor: 4.191

Review 4.  Iatrogenic injury from vascular access and endovascular procedures.

Authors:  Britt H Tonnessen
Journal:  Perspect Vasc Surg Endovasc Ther       Date:  2011-06

5.  Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis.

Authors:  Gian Paolo Ussia; Marco Barbanti; Anna Sonia Petronio; Giuseppe Tarantini; Federica Ettori; Antonio Colombo; Roberto Violini; Angelo Ramondo; Gennaro Santoro; Silvio Klugmann; Francesco Bedogni; Francesco Maisano; Antonio Marzocchi; Arnaldo Poli; Marco De Carlo; Massimo Napodano; Claudia Fiorina; Federico De Marco; David Antoniucci; Emanuela de Cillis; Davide Capodanno; Corrado Tamburino
Journal:  Eur Heart J       Date:  2012-01-12       Impact factor: 29.983

6.  A percutaneous aortic device for cerebral embolic protection during cardiovascular intervention.

Authors:  Jeffrey P Carpenter; Judith T Carpenter; Armando Tellez; John G Webb; Geng Hua Yi; Juan F Granada
Journal:  J Vasc Surg       Date:  2011-01-14       Impact factor: 4.268

7.  Transfemoral aortic valve implantation new criteria to predict vascular complications.

Authors:  Kentaro Hayashida; Thierry Lefèvre; Bernard Chevalier; Thomas Hovasse; Mauro Romano; Philippe Garot; Darren Mylotte; Jhonathan Uribe; Arnaud Farge; Patrick Donzeau-Gouge; Erik Bouvier; Bertrand Cormier; Marie-Claude Morice
Journal:  JACC Cardiovasc Interv       Date:  2011-08       Impact factor: 11.195

8.  Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve.

Authors:  Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Iassen Michev; Rüdiger Lange; William N Anderson; Olaf Wendler
Journal:  Circulation       Date:  2010-06-21       Impact factor: 29.690

9.  Transcranial Doppler microembolic signals and serum marker evidence of brain injury during transcatheter aortic valve implantation.

Authors:  B Reinsfelt; A Westerlind; D Ioanes; H Zetterberg; J Fredén-Lindqvist; S-E Ricksten
Journal:  Acta Anaesthesiol Scand       Date:  2011-10-19       Impact factor: 2.105

Review 10.  Current status of thoracic endografting and its adjunctive pharmacology.

Authors:  Ali Khoynezhad; Rolando Celis; Mehnoosh Hashemzadeh; Mohammad Reza Movahed; Ziba Jalali
Journal:  Expert Opin Pharmacother       Date:  2009-12       Impact factor: 3.889

View more
  1 in total

1.  Mechanism of Vascular Injury in Transcatheter Aortic Valve Replacement.

Authors:  E A Ovcharenko; K U Klyshnikov; A A Shilov; N A Kochergin; M A Rezvova; N V Belikov; V I Ganyukov
Journal:  Sovrem Tekhnologii Med       Date:  2021-06-28
  1 in total