Literature DB >> 22092012

Transcranial Doppler microembolic signals and serum marker evidence of brain injury during transcatheter aortic valve implantation.

B Reinsfelt1, A Westerlind, D Ioanes, H Zetterberg, J Fredén-Lindqvist, S-E Ricksten.   

Abstract

BACKGROUND: Recent studies have shown that transcatheter aortic valve implantation (TAVI) is associated with new foci of restricted diffusion on cerebral magnetic resonance imaging suggestive of cerebral microembolism. The aim of the present investigation was to quantify the cerebral embolic load and to evaluate during which phase of the TAVI procedure microembolism occurs. We also evaluated the association between the cerebral embolic load and post-procedural release of S100B, a serological marker of cerebral injury.
METHODS: In 21 patients, we described the extent and intra-procedural distribution of microemboli during the TAVI procedure using the transcranial Doppler technique. S100B, a marker of astroglial injury, was measured for 24 h after the procedure, and the area under the curve (AUC(24h) ) relating S100B to time was calculated.
RESULTS: During the TAVI procedure, a mean of 282 ± 169 emboli was detected, 37% occurred during manipulation of the aortic arch/root/valve by guide wires and catheters, 22% occurred immediately after balloon dilatation of the native valve and 41% occurred during frame expansion of the valve prosthesis. S100B increased in all patients with a peak at 1 h after the procedure and returned to baseline after 4 h. There was a positive correlation between the total amount of cerebral microemboli and the AUC(24h) for S100B (r = 0.68, P < 0.001). None of the patients developed neurological impairment.
CONCLUSION: TAVI is associated with a substantial amount of cerebral microemboli. The microembolic load correlates to the degree of post-procedural release of a marker of cerebral injury.
© 2011 The Authors Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22092012     DOI: 10.1111/j.1399-6576.2011.02563.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  11 in total

1.  Transcatheter valve implantation: damage to the human aorta after valved stent delivery system exposure--an in vitro study.

Authors:  Paul Philipp Heinisch; Oliver Richter; Michael Schünke; Rene Bombien Quaden
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-06-01

2.  Silent ischemic brain lesions after transcatheter aortic valve replacement: lesion distribution and predictors.

Authors:  Mariam Samim; Jeroen Hendrikse; H Bart van der Worp; Pierfrancesco Agostoni; Freek Nijhoff; Pieter A Doevendans; Pieter R Stella
Journal:  Clin Res Cardiol       Date:  2015-01-18       Impact factor: 5.460

Review 3.  Silent Brain Infarction, Delirium, and Cognition in Three Invasive Cardiovascular Procedures: a Systematic Review.

Authors:  Adam Gerstenecker; Amani M Norling; Alexandra Jacob; Ronald M Lazar
Journal:  Neuropsychol Rev       Date:  2022-07-08       Impact factor: 7.444

Review 4.  Silent cerebral infarcts associated with cardiac disease and procedures.

Authors:  Mariëlla E C Hassell; Robin Nijveldt; Yvo B W Roos; Charles B L Majoie; Martial Hamon; Jan J Piek; Ronak Delewi
Journal:  Nat Rev Cardiol       Date:  2013-10-29       Impact factor: 32.419

Review 5.  S100 and S100β: biomarkers of cerebral damage in cardiac surgery with or without the use of cardiopulmonary bypass.

Authors:  Shi-Min Yuan
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Oct-Dec

6.  Online transcranial Doppler ultrasonographic control of an onscreen keyboard.

Authors:  Jie Lu; Khondaker A Mamun; Tom Chau
Journal:  Front Hum Neurosci       Date:  2014-04-22       Impact factor: 3.169

Review 7.  Transcatheter Aortic Valve Implantation (TAVI): Is it Time for This Intervention to be Applied in a Lower Risk Population?

Authors:  Ioannis M Panayiotides; Evagoras Nikolaides
Journal:  Clin Med Insights Cardiol       Date:  2014-11-13

8.  A review of most relevant complications of transcatheter aortic valve implantation.

Authors:  Siyamek Neragi-Miandoab; Robert E Michler
Journal:  ISRN Cardiol       Date:  2013-05-12

9.  Stroke following transcatheter aortic valve implantation. Is neuroprotection justified?

Authors:  Maciej Dąbrowski; Adam Witkowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2013-11-18       Impact factor: 1.426

10.  The self-expanding Symetis Acurate does not increase cerebral microembolic load when compared to the balloon-expandable Edwards Sapien prosthesis: a transcranial Doppler study in patients undergoing transapical aortic valve implantation.

Authors:  Gabor Erdoes; Christoph Huber; Reto Basciani; Stefan Stortecky; Stephan Windecker; Peter Wenaweser; Thierry Carrel; Balthasar Eberle
Journal:  PLoS One       Date:  2014-10-07       Impact factor: 3.240