Literature DB >> 22658423

Three-dimensional speckle-tracking analysis of left ventricular function after transcatheter aortic valve implantation.

Robert Schueler1, Jan-Malte Sinning, Diana Momcilovic, Marcel Weber, Alexander Ghanem, Nikos Werner, Georg Nickenig, Eberhard Grube, Christoph Hammerstingl.   

Abstract

BACKGROUND: The acute and long-term effects of transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis on left ventricular (LV) function are controversial. The aim of this study was to determine the effect of TAVI on LV function with two-dimensional (2D) and three-dimensional (3D) speckle-tracking analysis of LV deformation capability.
METHODS: Patients underwent standardized 2D and 3D transthoracic echocardiography before TAVI and after 6 months of follow-up, including 3D and 2D LV deformation imaging.
RESULTS: Forty-four patients (mean age, 81.7 ± 5.5 years; 21 men [47.7%]; mean body mass index, 26.3 ± 5.1 kg/m(2); mean logistic European System for Cardiac Operative Risk Evaluation score, 24.4 ± 13.7%) undergoing TAVI were prospectively included. After follow-up, mean 3D LV ejection fraction (LVEF) (35.4 ± 13.1% vs 40.6 ± 12.6%, P = .004), 3D LV volumes (end-systolic volume, 85.9 ± 41.8 vs 65.9 ± 33.7 mL, P < .001; end-diastolic volume, 127.6 ± 40.7 vs 106.4 ± 40.9 mL, P = .001), 3D global longitudinal strain (-9.9 ± 3.7% vs -12.6 ± 4.2%, P < .001), and 3D LV twist (6.1 ± 4.3° vs 8.5 ± 6.9°, P = .025) were relevantly improved. LV improvement was pronounced in patients with decreased baseline LV function (area under the curve, 0.78; P < .001), with a cutoff value for 3D LVEF of ≤37% to identify functional responders to TAVI. After follow-up, patients with 3D LVEFs ≤ 37% showed a significant improvements in 3D LVEF (26.0 ± 7.6% vs 35.9 ± 11.7%, P < .001), 3D LV volumes (end-diastolic volume, 147.4 ± 40.6 vs 117.1 ± 45.5 mL, P = .001; end-systolic volume, 110.9 ± 39.2 vs 77.5 ± 37.2 mL, P < .001), 3D global longitudinal strain (-7.8 ± 2.7% vs -11.3 ± 4.2%, P < .001), and 3D LV twist (5.6 ± 4.2° vs 8.0 ± 5.6°, P = .047), whereas in patients with 3D LVEFs > 37%, only 3D global longitudinal strain was relevantly altered (-12.5 ± 3.1% vs -14.2 ± 3.8%, P = .04). Compared with 2D transthoracic echocardiography, 3D LV functional imaging allowed significantly faster image acquisition and data analysis (P < .0001). New York Heart Association functional class improved significantly in both groups (3D LVEF ≤ 37%, from 3.1 ± 0.5 to 2.0 ± 0.6, P < .001; 3D LVEF > 37%, from 2.7 ± 6.7 to 1.5 ± 0.7, P < .001), whereas a significant amelioration of N-terminal pro-brain natriuretic peptide was observed only in patients with baseline 3D LVEFs ≤ 37% (10,314.64 ± 11,682.2 vs 3,398.7 ± 3,598.9 pg/mL, P = .02; 3D LVEF > 37%, 10,306.4 ± 32,000.5 vs 2,868.0 ± 3,816.7 pg/mL, P = .12).
CONCLUSIONS: Our results indicate significant improvements of LV global and longitudinal function and clinical parameters 6 months after TAVI that are pronounced in patients with impaired baseline LV function. Compared with 2D LV functional imaging, 3D speckle-tracking imaging allowed significantly faster image acquisition and data analysis.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22658423     DOI: 10.1016/j.echo.2012.04.023

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  13 in total

1.  Improvements in global longitudinal strain after transcatheter aortic valve replacement according to race.

Authors:  Aamir H Twing; Brody Slostad; Christina Anderson; Sreenivas Konda; Elliott M Groves; Mayank M Kansal
Journal:  Am J Cardiovasc Dis       Date:  2021-04-15

2.  Impact of left ventricular conduction defect with or without need for permanent right ventricular pacing on functional and clinical recovery after TAVR.

Authors:  Marcel Weber; Eva Brüggemann; Robert Schueler; Diana Momcilovic; Jan-Malte Sinning; Alexander Ghanem; Nikos Werner; Eberhard Grube; Wolfgang Schiller; Fritz Mellert; Armin Welz; Georg Nickenig; Christoph Hammerstingl
Journal:  Clin Res Cardiol       Date:  2015-05-13       Impact factor: 5.460

3.  Are biventricular systolic functions impaired in patient with coronoray slow flow? A prospective study with three dimensional speckle tracking.

Authors:  Tuğba Kemaloğlu Öz; Mehmet Eren; Işıl Atasoy; Tayfun Gürol; Özer Soylu; Bahadır Dağdeviren
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-06       Impact factor: 2.357

Review 4.  Calcific Aortic Valve Disease: Part 1--Molecular Pathogenetic Aspects, Hemodynamics, and Adaptive Feedbacks.

Authors:  Ares Pasipoularides
Journal:  J Cardiovasc Transl Res       Date:  2016-02-18       Impact factor: 4.132

Review 5.  Three-dimensional speckle-tracking echocardiography: benefits and limitations of integrating myocardial mechanics with three-dimensional imaging.

Authors:  Denisa Muraru; Alice Niero; Hugo Rodriguez-Zanella; Diana Cherata; Luigi Badano
Journal:  Cardiovasc Diagn Ther       Date:  2018-02

6.  Echocardiographic evaluation of myocardial strain in patients after transcatheter aortic valve implantation.

Authors:  Tomasz Bochenek; Blazej Kusz; Magdalena Mizia; Michal Lelek; Maciej Turski; Krystian Wita; Andrzej Ochała; Katarzyna Mizia-Stec
Journal:  Postepy Kardiol Interwencyjnej       Date:  2015-06-22       Impact factor: 1.426

7.  Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement.

Authors:  Frédéric Poulin; Teerapat Yingchoncharoen; William M Wilson; Eric M Horlick; Philippe Généreux; E Murat Tuzcu; William Stewart; Mark D Osten; Anna Woo; Paaladinesh Thavendiranathan
Journal:  J Am Heart Assoc       Date:  2016-02-08       Impact factor: 5.501

8.  Reversibility of Cardiac Function Predicts Outcome After Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis.

Authors:  Kimi Sato; Arnav Kumar; Brandon M Jones; Stephanie L Mick; Amar Krishnaswamy; Richard A Grimm; Milind Y Desai; Brian P Griffin; L Leonardo Rodriguez; Samir R Kapadia; Nancy A Obuchowski; Zoran B Popović
Journal:  J Am Heart Assoc       Date:  2017-07-11       Impact factor: 5.501

Review 9.  A review of current trends in three-dimensional analysis of left ventricular myocardial strain.

Authors:  Yosuke Nabeshima; Yoshihiro Seo; Masaaki Takeuchi
Journal:  Cardiovasc Ultrasound       Date:  2020-06-26       Impact factor: 2.062

Review 10.  Functional status and quality of life after transcatheter aortic valve replacement: a systematic review.

Authors:  Caroline A Kim; Suraj P Rasania; Jonathan Afilalo; Jeffrey J Popma; Lewis A Lipsitz; Dae Hyun Kim
Journal:  Ann Intern Med       Date:  2014-02-18       Impact factor: 25.391

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.