Literature DB >> 22653465

Capillary-channeled polymer (C-CP) fibers as a stationary phase for sample clean-up of protein solutions for matrix-assisted laser/desorption ionization mass spectrometry.

Benjamin T Manard1, R Kenneth Marcus.   

Abstract

Capillary-channeled polymer (C-CP) fibers are employed in a micropipette tip format to affect a stationary phase for the solid phase extraction (SPE) of proteins from buffer solutions prior to MALDI-MS analysis. Proteins readily adsorb to the polypropylene (PP) C-CP fibers while buffer species are easily washed off the tips using DI-H(2)O. Elution of the solutes is achieved with an aliquot of 50:50 ACN:H(2)O, which is compatible with the subsequent spotting on the MALDI target with the matrix solution. Lysozyme and cytochrome c are used as test species, with a primary buffer composition of 100 mM Tris-HCl. In this case, direct MALDI-MS produces no discernible protein signals. SPE on the C-CP fibers yields high fidelity mass spectra for 1 μL sample volumes. Limits of detection for cytochrome c in 100 mM Tris-HCl are on the order of 40 nM. Extraction of cytochrome c from buffer concentrations of up to 1 M Tris-HCl, provides signal recoveries that are suppressed by only ~50% versus neat protein solutions. Finally, extraction of 3.1 μM cytochrome c from a synthetic urine matrix exhibits excellent recovery.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22653465     DOI: 10.1007/s13361-012-0399-6

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

1.  The use of a porous graphitic carbon column for desalting hydrophilic peptides prior to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  E T Chin; D I Papac
Journal:  Anal Biochem       Date:  1999-09-10       Impact factor: 3.365

2.  Solid-phase extraction/MALDI-MS: extended ion-pairing surfaces for the on-target cleanup of protein samples.

Authors:  L Zhang; R Orlando
Journal:  Anal Chem       Date:  1999-10-15       Impact factor: 6.986

Review 3.  Recent developments in polymer-based sorbents for solid-phase extraction.

Authors:  C W Huck; G K Bonn
Journal:  J Chromatogr A       Date:  2000-07-14       Impact factor: 4.759

Review 4.  Analysis of proteins and proteomes by mass spectrometry.

Authors:  M Mann; R C Hendrickson; A Pandey
Journal:  Annu Rev Biochem       Date:  2001       Impact factor: 23.643

5.  Stop and go extraction tips for matrix-assisted laser desorption/ionization, nanoelectrospray, and LC/MS sample pretreatment in proteomics.

Authors:  Juri Rappsilber; Yasushi Ishihama; Matthias Mann
Journal:  Anal Chem       Date:  2003-02-01       Impact factor: 6.986

6.  Non-specific, on-probe cleanup methods for MALDI-MS samples.

Authors:  Yingda Xu; Merlin L Bruening; J Throck Watson
Journal:  Mass Spectrom Rev       Date:  2003 Nov-Dec       Impact factor: 10.946

7.  Modular stop and go extraction tips with stacked disks for parallel and multidimensional Peptide fractionation in proteomics.

Authors:  Yasushi Ishihama; Juri Rappsilber; Matthias Mann
Journal:  J Proteome Res       Date:  2006-04       Impact factor: 4.466

8.  Capillary-channeled polymer fibers as a stationary phase for desalting of protein solutions for electrospray ionization mass spectrometry analysis.

Authors:  D Seth Fornea; Yonnie Wu; R Kenneth Marcus
Journal:  Anal Chem       Date:  2006-08-01       Impact factor: 6.986

9.  Capillary-channeled polymer fibers as stationary phases in liquid chromatography separations.

Authors:  R Kenneth Marcus; W Clay Davis; Brad C Knippel; LaTasha LaMotte; Teresa A Hill; Dvora Perahia; J David Jenkins
Journal:  J Chromatogr A       Date:  2003-01-31       Impact factor: 4.759

10.  Characterization of capillary-channeled polymer fiber stationary phases for high-performance liquid chromatography protein separations: Comparative analysis with a packed-bed column.

Authors:  Dwella M Nelson; R Kenneth Marcus
Journal:  Anal Chem       Date:  2006-12-15       Impact factor: 6.986

View more
  1 in total

1.  In-line desalting of proteins from buffer and synthetic urine solution prior to ESI-MS analysis via a capillary-channeled polymer fiber microcolumn.

Authors:  Carolyn Q Burdette; R Kenneth Marcus
Journal:  J Am Soc Mass Spectrom       Date:  2013-03-05       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.