Literature DB >> 17165840

Characterization of capillary-channeled polymer fiber stationary phases for high-performance liquid chromatography protein separations: Comparative analysis with a packed-bed column.

Dwella M Nelson1, R Kenneth Marcus.   

Abstract

Capillary-channeled polymer (C-CP) fibers are investigated as reversed-phase (RP) stationary phases for high-performance liquid chromatography of proteins. A comparative analysis of column characteristics for polypropylene and poly(ethylene terephthalate) C-CP fiber columns and a conventional packed-bed (C4-derivatized silica) column has been undertaken. Five proteins (ribonuclease A, cytochrome c, lysozyme, myoglobin, bovine serum albumin) were used to investigate the separation characteristics under typical RP gradient conditions. Column performance was compared under standard (identical) and optimized RP chromatographic conditions. The gradient compositions utilized with the C-CP fiber columns are similar to those used with conventional columns, employing flow rates in the 1-6 mL/min range and gradient rates of approximately 1%/min. The packed-bed column was operated as prescribed by the column manufacturer. The retention factor (k'), separation factor (alpha), resolution (Rs), asymmetry factor (As), elution order, and peak capacity values of a four protein separations performed on the C-CP fiber columns are compared to the same separation on the C4 column. One unique feature observed here is the lessening of the percentage of organic modifier necessary to elute the proteins from the fiber phases with increased linear velocity. The potential contribution of the different stationary phases to protein denaturation was evaluated through a spectrophotometric enzymatic activity assay. The repeatability of retention times under both sets of conditions for six consecutive injections of lysozyme on each C-CP fiber column is < or =1.5% RSD. The column-to-column reproducibility of retention times for three columns of each fiber type is also < or =1.5% RSD. The overall performance of the C-CP fiber columns was comparable to the conventional column used in these studies. Basic characteristics demonstrated here suggested further developments in the areas of ultrafast protein separations and preparative-scale protein chromatography.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17165840     DOI: 10.1021/ac061223w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Capillary-channeled polymer (C-CP) fibers as a stationary phase for sample clean-up of protein solutions for matrix-assisted laser/desorption ionization mass spectrometry.

Authors:  Benjamin T Manard; R Kenneth Marcus
Journal:  J Am Soc Mass Spectrom       Date:  2012-06-01       Impact factor: 3.109

2.  Capillary-channeled polymer (C-CP) films as processing platforms for protein analysis by matrix-assisted laser/desorption ionization mass spectrometry (MALDI-MS).

Authors:  Jennifer J Pittman; Benjamin T Manard; Paul J Kowalski; R Kenneth Marcus
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-20       Impact factor: 3.109

3.  In-line desalting of proteins from buffer and synthetic urine solution prior to ESI-MS analysis via a capillary-channeled polymer fiber microcolumn.

Authors:  Carolyn Q Burdette; R Kenneth Marcus
Journal:  J Am Soc Mass Spectrom       Date:  2013-03-05       Impact factor: 3.109

4.  Solid-phase extraction of exosomes from diverse matrices via a polyester capillary-channeled polymer (C-CP) fiber stationary phase in a spin-down tip format.

Authors:  Kaylan K Jackson; Rhonda R Powell; Terri F Bruce; R Kenneth Marcus
Journal:  Anal Bioanal Chem       Date:  2020-05-28       Impact factor: 4.478

  4 in total