Literature DB >> 22652262

Optimization of antibiotic analysis in water by solid-phase extraction and high performance liquid chromatography-mass spectrometry/mass spectrometry.

John L Zhou1, Khalid Maskaoui, Adeleye Lufadeju.   

Abstract

This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC-MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C(18) endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min(-1). The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L(-1) in river water and between <LOD to 230 ng L(-1) in sewage effluent.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22652262     DOI: 10.1016/j.aca.2012.04.021

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

1.  Antibiotics in hospital effluents: occurrence, contribution to urban wastewater, removal in a wastewater treatment plant, and environmental risk assessment.

Authors:  Senar Aydin; Mehmet Emin Aydin; Arzu Ulvi; Havva Kilic
Journal:  Environ Sci Pollut Res Int       Date:  2018-11-08       Impact factor: 4.223

2.  Multi-class determination of pharmaceuticals in wastewaters by solid-phase extraction and liquid chromatography tandem mass spectrometry with matrix effect study.

Authors:  Mirta Čizmić; Sandra Babić; Marija Kaštelan-Macan
Journal:  Environ Sci Pollut Res Int       Date:  2017-07-15       Impact factor: 4.223

3.  Aptamer based voltammetric determination of ampicillin using a single-stranded DNA binding protein and DNA functionalized gold nanoparticles.

Authors:  Jun Wang; Kui Ma; Huanshun Yin; Yunlei Zhou; Shiyun Ai
Journal:  Mikrochim Acta       Date:  2017-12-20       Impact factor: 5.833

4.  Ultra-high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of antibiotic residues in environmental waters.

Authors:  Qiang Xue; Yanjie Qi; Fei Liu
Journal:  Environ Sci Pollut Res Int       Date:  2015-06-24       Impact factor: 4.223

Review 5.  Recent Advances and Perspectives on the Sources and Detection of Antibiotics in Aquatic Environments.

Authors:  Yanbo Zeng; Fengqin Chang; Qi Liu; Lizeng Duan; Donglin Li; Hucai Zhang
Journal:  J Anal Methods Chem       Date:  2022-05-25       Impact factor: 2.594

6.  An optimized SPE-LC-MS/MS method for antibiotics residue analysis in ground, surface and treated water samples by response surface methodology- central composite design.

Authors:  Roya Mirzaei; Masoud Yunesian; Simin Nasseri; Mitra Gholami; Esfandiyar Jalilzadeh; Shahram Shoeibi; Hooshang Shafieyan Bidshahi; Alireza Mesdaghinia
Journal:  J Environ Health Sci Eng       Date:  2017-10-17

7.  Determination of Ten Macrolide Drugs in Environmental Water Using Molecularly Imprinted Solid-Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Xuqin Song; Tong Zhou; Jiufeng Li; Meiyu Zhang; Jingmeng Xie; Limin He
Journal:  Molecules       Date:  2018-05-14       Impact factor: 4.411

8.  Untargeted characterisation of dissolved organic matter contributions to rivers from anthropogenic point sources using direct-infusion and high-performance liquid chromatography/Orbitrap mass spectrometry.

Authors:  Jonathan A Pemberton; Charlotte E M Lloyd; Christopher J Arthur; Penny J Johnes; Michael Dickinson; Adrian J Charlton; Richard P Evershed
Journal:  Rapid Commun Mass Spectrom       Date:  2020-02-13       Impact factor: 2.419

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.