Literature DB >> 22651886

Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.

Yupaporn Sameenoi1, Kirsten Koehler, Jeff Shapiro, Kanokporn Boonsong, Yele Sun, Jeffrey Collett, John Volckens, Charles S Henry.   

Abstract

Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22651886      PMCID: PMC3397383          DOI: 10.1021/ja3031104

Source DB:  PubMed          Journal:  J Am Chem Soc        ISSN: 0002-7863            Impact factor:   15.419


  40 in total

1.  Integration of a carbon microelectrode with a microfabricated palladium decoupler for use in microchip capillary electrophoresis/electrochemistry.

Authors:  Michelle L Kovarik; Michelle W Li; R Scott Martin
Journal:  Electrophoresis       Date:  2005-01       Impact factor: 3.535

Review 2.  Electrochemical techniques for microfluidic applications.

Authors:  Fumihiro Sassa; Katsuya Morimoto; Wataru Satoh; Hiroaki Suzuki
Journal:  Electrophoresis       Date:  2008-05       Impact factor: 3.535

3.  Multiplexed proteomic sample preconcentration device using surface-patterned ion-selective membrane.

Authors:  Jeong Hoon Lee; Yong-Ak Song; Jongyoon Han
Journal:  Lab Chip       Date:  2008-03-04       Impact factor: 6.799

Review 4.  Integration of electrochemistry in micro-total analysis systems for biochemical assays: recent developments.

Authors:  Xiaoli Xu; Song Zhang; Hui Chen; Jilie Kong
Journal:  Talanta       Date:  2009-06-24       Impact factor: 6.057

5.  Genotoxicity and physicochemical characteristics of traffic-related ambient particulate matter.

Authors:  Theo M de Kok; Janneke G Hogervorst; Jacco J Briedé; Marcel H van Herwijnen; Lou M Maas; Edwin J Moonen; Hermen A Driece; Jos C Kleinjans
Journal:  Environ Mol Mutagen       Date:  2005-08       Impact factor: 3.216

6.  Detecting thiols in a microchip device using micromolded carbon ink electrodes modified with cobalt phthalocyanine.

Authors:  Courtney D Kuhnline; Michael G Gangel; Matthew K Hulvey; R Scott Martin
Journal:  Analyst       Date:  2005-11-23       Impact factor: 4.616

Review 7.  Advances in integrated and continuous measurements for particle mass and chemical composition.

Authors:  Judith C Chow; Prakash Doraiswamy; John G Watson; L W Antony Chen; Steven Sai Hang Ho; David A Sodeman
Journal:  J Air Waste Manag Assoc       Date:  2008-02       Impact factor: 2.235

8.  Use of proteomics to demonstrate a hierarchical oxidative stress response to diesel exhaust particle chemicals in a macrophage cell line.

Authors:  Gary Guishan Xiao; Meiying Wang; Ning Li; Joseph A Loo; Andre E Nel
Journal:  J Biol Chem       Date:  2003-09-30       Impact factor: 5.157

9.  Laboratory and field testing of an automated atmospheric particle-bound reactive oxygen species sampling-analysis system.

Authors:  Yungang Wang; Philip K Hopke; Liping Sun; David C Chalupa; Mark J Utell
Journal:  J Toxicol       Date:  2011-03-24

10.  Relationship between redox activity and chemical speciation of size-fractionated particulate matter.

Authors:  Leonidas Ntziachristos; John R Froines; Arthur K Cho; Constantinos Sioutas
Journal:  Part Fibre Toxicol       Date:  2007-06-07       Impact factor: 9.400

View more
  17 in total

1.  In vivo monitoring of serotonin in the striatum of freely moving rats with one minute temporal resolution by online microdialysis-capillary high-performance liquid chromatography at elevated temperature and pressure.

Authors:  Jing Zhang; Andrea Jaquins-Gerstl; Kathryn M Nesbitt; Sarah C Rutan; Adrian C Michael; Stephen G Weber
Journal:  Anal Chem       Date:  2013-09-24       Impact factor: 6.986

2.  A new method and tool for detection and quantification of PM oxidative potential.

Authors:  Francesco Ciriello; Maurizio Gualtieri; Eleonora Longhin; Riccardo Ruffo; Marina Camatini; Paolo Parenti
Journal:  Environ Sci Pollut Res Int       Date:  2015-04-24       Impact factor: 4.223

3.  A Simple Microfluidic Electrochemical HPLC Detector for Quantifying Fenton Reactivity from Welding Fumes.

Authors:  Thanakorn Pluangklang; John B Wydallis; David M Cate; Duangjai Nacapricha; Charles S Henry
Journal:  Anal Methods       Date:  2014-10-21       Impact factor: 2.896

Review 4.  Micro total analysis systems: fundamental advances and applications in the laboratory, clinic, and field.

Authors:  Michelle L Kovarik; Douglas M Ornoff; Adam T Melvin; Nicholas C Dobes; Yuli Wang; Alexandra J Dickinson; Philip C Gach; Pavak K Shah; Nancy L Allbritton
Journal:  Anal Chem       Date:  2012-12-04       Impact factor: 6.986

5.  LABORATORY EVALUATION OF A MICROFLUIDIC ELECTROCHEMICAL SENSOR FOR AEROSOL OXIDATIVE LOAD.

Authors:  Kirsten Koehler; Jeffrey Shapiro; Yupaporn Sameenoi; Charles Henry; John Volckens
Journal:  Aerosol Sci Technol       Date:  2014-05-01       Impact factor: 2.908

Review 6.  New Methods for Personal Exposure Monitoring for Airborne Particles.

Authors:  Kirsten A Koehler; Thomas M Peters
Journal:  Curr Environ Health Rep       Date:  2015-12

7.  A bias in the "mass-normalized" DTT response - an effect of non-linear concentration-response curves for copper and manganese.

Authors:  Jessica G Charrier; Alexander S McFall; Kennedy K-T Vu; James Baroi; Catalina Olea; Alam Hasson; Cort Anastasio
Journal:  Atmos Environ (1994)       Date:  2016-09-04       Impact factor: 4.798

8.  Microfluidic paper-based analytical device for aerosol oxidative activity.

Authors:  Yupaporn Sameenoi; Pantila Panymeesamer; Natcha Supalakorn; Kirsten Koehler; Orawon Chailapakul; Charles S Henry; John Volckens
Journal:  Environ Sci Technol       Date:  2012-12-21       Impact factor: 9.028

9.  Determination of aerosol oxidative activity using silver nanoparticle aggregation on paper-based analytical devices.

Authors:  Wijitar Dungchai; Yupaporn Sameenoi; Orawon Chailapakul; John Volckens; Charles S Henry
Journal:  Analyst       Date:  2013-11-21       Impact factor: 4.616

10.  Electrochemical Dithiothreitol Assay for Large-Scale Particulate Matter Studies.

Authors:  Kathleen E Berg; Laurelle R Turner; Megan L Benka-Coker; Sarah Rajkumar; Bonnie N Young; Jennifer L Peel; Maggie L Clark; John Volckens; Charles S Henry
Journal:  Aerosol Sci Technol       Date:  2019-01-24       Impact factor: 2.908

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.