Reoperation on a Starr-Edwards ball valve without structural deterioration.

Yukihiro Hayatsu1, Takeshi Saito, Osamu Adachi, Kiichiro Kumagai, Masatoshi Akiyama, Naotaka Motoyoshi, Shunsuke Kawamoto, Yoshikatsu Saiki.   

Abstract

Accurate measurement of pressure gradients on echocardiography across a Starr-Edwards (SE) ball valve is difficult due to its unique flow pattern. The decision of indication for reoperation on the valve requires multifactorical evaluation. We report a surgical case with an aortic SE ball valve 43 years after implantation. There was no apparent structural deterioration on the ball per se, yet, remarkable pannus formation was noted beneath the sewing cuff in the left ventricular outflow tract.

Entities:  

Mesh:

Year:  2012        PMID: 22644821     DOI: 10.1007/s11748-012-0092-5

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  8 in total

1.  Mitral replacement: clinical experience with a ball-valve prosthesis.

Authors:  A STARR; M L EDWARDS
Journal:  Ann Surg       Date:  1961-10       Impact factor: 12.969

2.  Partial and complete prostheses in aortic insufficiency.

Authors:  D E HARKEN; H S SOROFF; W J TAYLOR; A A LEFEMINE; S K GUPTA; S LUNZER
Journal:  J Thorac Cardiovasc Surg       Date:  1960-12       Impact factor: 5.209

3.  Surgical correction of aortic insufficiency.

Authors:  C A HUFNAGEL; W P HARVEY; P J RABIL; T F McDERMOTT
Journal:  Surgery       Date:  1954-05       Impact factor: 3.982

4.  Explantation of a 44-year-old Starr-Edwards mitral valve for delayed hemolysis.

Authors:  Joss Fernandez; Robert Saeid Farivar
Journal:  J Thorac Cardiovasc Surg       Date:  2010-02-01       Impact factor: 5.209

5.  Doppler echocardiographic assessment of normally functioning Starr-Edwards, carbomedics and Carpentier-Edwards valves in aortic position.

Authors:  B Chakraborty; S Quek; D Z Pin; C T Siong; T L Kheng
Journal:  Angiology       Date:  1996-05       Impact factor: 3.619

6.  Event status of the Starr-Edwards aortic valve to 20 years: a benchmark for comparison.

Authors:  T A Orszulak; H V Schaff; F J Puga; G K Danielson; C J Mullany; B J Anderson; D M Ilstrup
Journal:  Ann Thorac Surg       Date:  1997-03       Impact factor: 4.330

7.  Thirty-year results of Starr-Edwards prostheses in the aortic and mitral position.

Authors:  O L Gödje; T Fischlein; K Adelhard; G Nollert; W Klinner; B Reichart
Journal:  Ann Thorac Surg       Date:  1997-03       Impact factor: 4.330

8.  Valve dysfunction of the cloth-covered Starr-Edwards ball valve.

Authors:  Motomi Shiono; Akira Sezai; Mitsumasa Hata; Mitsuru Iida; Nanao Negishi; Yukiyasu Sezai
Journal:  Circ J       Date:  2005-07       Impact factor: 2.993

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.