Literature DB >> 22644151

Implementation of comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry for the simultaneous determination of halogenated contaminants and polycyclic aromatic hydrocarbons in fish.

Kamila Kalachova1, Jana Pulkrabova, Tomas Cajka, Lucie Drabova, Jana Hajslova.   

Abstract

In the presented study, comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC × GC-TOFMS) was shown to be a powerful tool for the simultaneous determination of various groups of contaminants including 18 polychlorinated biphenyls (PCBs), seven polybrominated diphenyl ethers (PBDEs), and 16 polycyclic aromatic hydrocarbons (PAHs). Since different groups of analytes (traditionally analyzed separately) were included into one instrumental method, significant time savings were achieved. Following the development of an integrated sample preparation procedure for an effective and rapid isolation of several groups of contaminants from fish tissue, the GC × GC-TOFMS instrumental method was optimized to obtain the best chromatographic resolution and low quantification limits (LOQs) of all target analytes in a complex mixture. Using large-volume programmable temperature vaporization, the following LOQs were achieved-PCBs, 0.01-0.25 μg/kg; PBDEs, 0.025-5 μg/kg; PAHs 0.025-0.5 μg/kg. Furthermore, several capillary column combinations (BPX5, BPX50, and Rxi-17Sil-ms in the first dimension and BPX5, BPX50, Rt-LC35, and HT8 in the second dimension) were tested during the experiments, and the optimal separation of all target analytes even of critical groups of PAHs (group (a): benz[a]anthracene, cyclopenta[cd]pyrene and chrysene; group (b): benzo[b]fluoranthene, benzo[j]fluoranthene and benzo[k]fluoranthene; group (c): dibenz[ah]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene) was observed on BPX5 × BPX50 column setup. Moreover, since the determination of target analytes was performed using TOFMS detector, further identification of other non-target compounds in real life samples was also feasible.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22644151     DOI: 10.1007/s00216-012-6095-3

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Cold-induced aqueous acetonitrile phase separation: A salt-free way to begin quick, easy, cheap, effective, rugged, safe.

Authors:  Gang Shao; Jeffrey Agar; Roger W Giese
Journal:  J Chromatogr A       Date:  2017-05-23       Impact factor: 4.759

2.  The Occurrence of 16 EPA PAHs in Food - A Review.

Authors:  Zuzana Zelinkova; Thomas Wenzl
Journal:  Polycycl Aromat Compd       Date:  2015-11-16

3.  Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran's Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry.

Authors:  Ramezan Sadeghi; Farzad Kobarfard; Hassan Yazdanpanah; Samira Eslamizad; Mitra Bayate
Journal:  Iran J Pharm Res       Date:  2016       Impact factor: 1.696

Review 4.  MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications.

Authors:  Federica Bianchi; Nicolò Riboni; Veronica Termopoli; Lucia Mendez; Isabel Medina; Leopold Ilag; Achille Cappiello; Maria Careri
Journal:  J Anal Methods Chem       Date:  2018-04-23       Impact factor: 2.193

Review 5.  Persistent Organic Pollutants in Food: Contamination Sources, Health Effects and Detection Methods.

Authors:  Wenjing Guo; Bohu Pan; Sugunadevi Sakkiah; Gokhan Yavas; Weigong Ge; Wen Zou; Weida Tong; Huixiao Hong
Journal:  Int J Environ Res Public Health       Date:  2019-11-08       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.