Stability of osseointegrated bone conduction systems in children: a pilot study.

Pasquale Marsella1, Alessandro Scorpecci, Riccardo D'Eredità, Antonio Della Volpe, Paolo Malerba.   

Abstract

OBJECTIVES: To obtain objective data of bone conduction implant stability and osseointegration in children; to compare in pediatric subjects the stability and osseointegration of the novel TiOblast-coated implant system (BI300) to the previous generation, as-machined model. STUDY
DESIGN: Multicenter, controlled, nonrandomized, longitudinal, prospective study.
SETTING: Tertiary referral center. LEVEL OF EVIDENCE: IIIb PATIENTS: Ten subjects were enrolled, aged younger than 16 years and without comorbidities that negatively affect osseointegration. All patients were implanted "single stage": 5 received the previous generation, pure titanium fixture (control group), and 5 were implanted the BI300, TiOblast-coated fixture (test group).
INTERVENTIONS: Measurement of implant stability and osseointegration. MAIN OUTCOME MEASURE(S): Implant stability and osseointegration as measured by means of resonance frequency analysis intraoperatively, at 1 week, 2 weeks, 1 month, and every month till processor loading 6 months after surgery.
RESULTS: BI300 is, on average, more stable than the control fixture, both intraoperatively and over time till processor loading. Over the 6 months' follow-up, a stability increase was observed with both models, although it resulted statistically not significant.
CONCLUSION: The BI300 implant system has a greater primary stability as compared with the previous generation model, but its faster osseointegration could not be definitely verified. It is reasonable to assume that the BI300 fixture will enable surgeons to perform single-stage surgery more safely and with a lower failure rate. The possibility of an earlier processor loading remains to be confirmed in a greater sample.

Entities:  

Mesh:

Year:  2012        PMID: 22643446     DOI: 10.1097/MAO.0b013e318255dd73

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  4 in total

1.  Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use.

Authors:  Sébastien Schmerber; O Deguine; M Marx; P Van de Heyning; O Sterkers; I Mosnier; P Garin; B Godey; C Vincent; F Venail; M Mondain; A Deveze; J P Lavieille; A Karkas
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-07-30       Impact factor: 2.503

2.  A new wide-diameter bone-anchored hearing implant-prospective 1-year data on complications, implant stability, and survival.

Authors:  Søren Foghsgaard; Per Caye-Thomasen
Journal:  Otol Neurotol       Date:  2014-08       Impact factor: 2.311

3.  Stability, Survival, and Tolerability of an Auditory Osseointegrated Implant for Bone Conduction Hearing: Long-Term Follow-Up of a Randomized Controlled Trial.

Authors:  Christine A den Besten; Joacim Stalfors; Stina Wigren; Johan Ivarsson Blechert; Mark Flynn; Måns Eeg-Olofsson; Rohini Aggarwal; Kevin Green; Rik C Nelissen; Emmanuel A M Mylanus; Myrthe K S Hol
Journal:  Otol Neurotol       Date:  2016-09       Impact factor: 2.311

4.  Stability Testing of a Wide Bone-Anchored Device after Surgery without Skin Thinning.

Authors:  Malou Hultcrantz
Journal:  Biomed Res Int       Date:  2015-07-05       Impact factor: 3.411