Literature DB >> 22633592

Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study.

Su-Jin Ahn1, Richard Leesungbok, Suk-Won Lee, Young-Ku Heo, Kyung Lhi Kang.   

Abstract

STATEMENT OF PROBLEM: It is difficult to achieve the primary stability necessary for immediate loading in the posterior maxilla because of thin cortical bone, low density trabecular bone, and inadequate bone height due to the presence of the maxillary sinus.
PURPOSE: The purpose of this study was to examine the primary stability of dental implants placed by using different methods of preparation for in vitro monocortical and bicortical models of the posterior maxilla.
MATERIAL AND METHODS: Sixty screw-shaped implants (4.0 × 10 mm) were inserted into solid rigid polyurethane blocks. The implants were divided into 6 groups (n=10) to test 2 variables: 1) location (monocortical or bicortical block) and 2) preparation method (standard preparation, underpreparation, or the osteotome technique). The insertion and removal torques were measured and resonance frequency analysis (RFA) was performed to determine the primary stability of each implant. Insertion and removal torque data were analyzed by 2-way ANOVA, followed by the post hoc Tukey HSD multiple comparison test. RFA data were analyzed by 2-way and 1-way ANOVAs and the Tukey HSD multiple comparison test (α=.05). The Pearson correlation analysis was also performed to examine correlations among the values.
RESULTS: The preparation method had a significant effect on insertion torque, RFA value, and removal torque; however location had a significant effect only on the removal torque (P<.001). There was a significant interaction between location and preparation method for RFA values (P=.045) and a significant difference in standard preparation method according to the location (P=.039); however, there was no significant difference in underpreparation (P=1.00) and osteotome technique (P=1.00). Statistically significant correlations were found between insertion torque and RFA values (r=0.529, P< .001), insertion torque and removal torque values (r=0.517, P< .001), and removal torque and RFA values (r=0.481, P<.001).
CONCLUSIONS: Underpreparation and bicortical fixation significantly increased implant stability and the osteotome technique decreased implant stability in synthetic bone models that mimicked the posterior maxillary region. The primary stability values had statistically significant correlations to each other.
Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22633592     DOI: 10.1016/S0022-3913(12)60092-4

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  15 in total

1.  Effect of Light Emitting Diode Photobiomodulation on the Stability of Dental Implants in Bone Grafted Cases: a Split-Mouth Randomized Clinical Trial.

Authors:  Atabak Kashefimehr; Mahdi Rahbar; Masoumeh Faramarzi; Amirreza Babaloo; Mehrnoosh Sadighi; Abbas Goshaderoo
Journal:  Maedica (Bucur)       Date:  2021-06

2.  Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study.

Authors:  David Chávarri-Prado; Aritza Brizuela-Velasco; Markel Diéguez-Pereira; Esteban Pérez-Pevida; Antonio Jiménez-Garrudo; Iratxe Viteri-Agustín; Alejandro Estrada-Martínez; Oier Montalbán-Vadillo
Journal:  J Clin Exp Dent       Date:  2020-03-01

3.  Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study.

Authors:  J Barberá-Millán; C Larrazábal-Morón; J-J Enciso-Ripoll; E Pérez-Pevida; D Chávarri-Prado; M-D Gómez-Adrián
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2021-05-01

4.  Three-Dimensional Finite Element Analysis of Anterior Single Implant-Supported Prostheses with Different Bone Anchorages.

Authors:  Fellippo Ramos Verri; Joel Ferreira Santiago Júnior; Daniel Augusto de Faria Almeida; Ana Caroline Gonçales Verri; Victor Eduardo de Souza Batista; Cleidiel Aparecido Araujo Lemos; Pedro Yoshito Noritomi; Eduardo Piza Pellizzer
Journal:  ScientificWorldJournal       Date:  2015-08-13

5.  Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading.

Authors:  Seong-Beom Kim; Pil-Young Yun; Sang-Yun Kim; Yang-Jin Yi; Ji-Yun Kim; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

6.  Effect of implant design on primary stability using torque-time curves in artificial bone.

Authors:  Yoko Yamaguchi; Makoto Shiota; Motohiro Munakata; Shohei Kasugai; Masahiko Ozeki
Journal:  Int J Implant Dent       Date:  2015-08-08

7.  Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study.

Authors:  Ho-Chyul Han; Hyun-Chang Lim; Ji-Youn Hong; Su-Jin Ahn; Ji-Young Han; Seung-Il Shin; Jong-Hyuk Chung; Yeek Herr; Seung-Yun Shin
Journal:  J Periodontal Implant Sci       Date:  2016-08-30       Impact factor: 2.614

8.  Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis.

Authors:  Gorka Santamaría-Arrieta; Aritza Brizuela-Velasco; Felipe J Fernández-González; David Chávarri-Prado; Yelko Chento-Valiente; Eneko Solaberrieta; Markel Diéguez-Pereira; José-Antonio Vega; Jaime Yurrebaso-Asúa
Journal:  J Clin Exp Dent       Date:  2016-07-01

9.  Development and application of a direct method to observe the implant/bone interface using simulated bone.

Authors:  Yoko Yamaguchi; Makoto Shiota; Masaki FuJii; Michi Sekiya; Masahiko Ozeki
Journal:  Springerplus       Date:  2016-04-21

10.  Comparison of Implant Stability Using Resonance Frequency Analysis: Osteotome Versus Conventional Drilling.

Authors:  Rokhsareh Sadeghi; Amir Reza Rokn; Asghar Miremadi
Journal:  J Dent (Tehran)       Date:  2015-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.