Literature DB >> 22626813

The effects of prewarming the I-gel on fitting to laryngeal structure.

Tomoki Nishiyama1, Yumiko Kohno, Ha Jung Kim, Won Jung Shin, Hong Seuk Yang.   

Abstract

PURPOSE: The supraglottic airway, I-gel (Intersurgical, Wokingham, United Kingdom), has a noninflatable cuff, which softens at body temperature to fit to laryngeal structure. The present study was performed to investigate the hypothesis that the cuff of I-gel can fit to laryngeal structure faster when prewarmed to body temperature than kept at room temperature.
METHODS: A total of 180 adult patients were assigned to the warm group (90 patients) or the control group (90 patients). Anesthesia was induced with propofol, remifentanil, or fentanyl. Vecuronium or rocuronium was administered as a muscle relaxant. The I-gel was warmed to 37 °C before insertion in the warm group and it was in the room temperature (approximately 20 °C) in the control group. Insertion time, number of attempt for successful insertion, inspiratory pressure, leak pressure, and leak volume were compared between the 2 groups.
RESULTS: Insertion time was 12.9 ± 9.3 seconds in the warm group and 14.5 ± 12.3 seconds in the control group. Number of attempt for insertion was 1 in 77 cases, 2 in 4 cases, and 3 in 1 case in the warm group and 1 in 79 cases and 2 in 7 cases in the control group. Inspiratory pressure, leak pressure, and leak volume were not significantly different between the 2 groups, whereas leak volume had a tendency to be smaller in the warm group.
CONCLUSION: Prewarming the I-gel to body temperature did not have any significant benefits in comparison with the I-gel kept at room temperature.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22626813     DOI: 10.1016/j.ajem.2012.02.009

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  5 in total

1.  Does prewarming the i-gel supraglottic airway device fit the larynx better compared to keeping it at room temperature for non-paralysed, sedated patients: a randomised controlled trial.

Authors:  Nobuyasu Komasawa; Isao Nishihara; Shinichi Tatsumi; Toshiaki Minami
Journal:  BMJ Open       Date:  2015-01-13       Impact factor: 2.692

2.  Does prewarming of i-gel improve insertion and ventilation in anaesthetised and paralysed patients? A prospective, randomised, control trial.

Authors:  Aamuktha Malyadha Reddy; Nita Varghese; Basavaraj Herekar; Udupi Kailashnath Shenoy
Journal:  Saudi J Anaesth       Date:  2019 Jul-Sep

3.  Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA) improves fitting to the laryngeal structure: a randomized, double-blind study.

Authors:  Hyun Kang; Dong Rim Kim; Yong Hun Jung; Chong Wha Baek; Yong Hee Park; Jong In Oh; Won Joong Kim; Geun Joo Choi
Journal:  BMC Anesthesiol       Date:  2015-11-20       Impact factor: 2.217

Review 4.  Extraglottic airway devices: technology update.

Authors:  Bimla Sharma; Chand Sahai; Jayashree Sood
Journal:  Med Devices (Auckl)       Date:  2017-08-17

5.  Influence of head and neck positions on oropharyngeal seal pressure with Baska mask® versus I-gel™; A randomised clinical study.

Authors:  Gurkaran Kaur Sidhu; Seema Jindal; Rupali Mahajan; Sheetal Bhagat
Journal:  Indian J Anaesth       Date:  2020-07-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.