Multicenter evaluation of Edwards SAPIEN positioning during transcatheter aortic valve implantation with correlates for device movement during final deployment.

Danny Dvir1, Ifat Lavi1, Hélène Eltchaninoff2, Dominique Himbert3, Yaron Almagor4, Fleur Descoutures3, Alec Vahanian3, Christophe Tron2, Alain Cribier2, Ran Kornowski5.   

Abstract

OBJECTIVES: This study sought to evaluate the exact location of Edwards SAPIEN (Edwards Lifesciences, Irvine, California) devices in different stages of implantation and to quantify possible operator-independent device movement during final deployment.
BACKGROUND: Accurate device positioning during transcatheter aortic valve implantation is crucial in order to achieve optimal results.
METHODS: This multicenter study consisted of 68 procedures with reliable pacemaker capture. Device positions were assessed using fluoroscopic images and the C-THV system (Paieon Medical, Rosh Ha'Ayin, Israel).
RESULTS: The location after implantation was significantly higher than in the final stage of rapid pacing: 16.7 ± 16.3% of device height below the plane of the lower sinus border versus 32.6 ± 13.8%, p < 0.0001. Operator-independent device-center upper movement during final deployment was 2 ± 1.43 mm, range: -1.3 to 4.6 mm. Device movement was asymmetrical, occurring more in the lower part of the device than in its upper part (3.2 ± 1.4 mm vs. 0.75 ± 1.5 mm, p < 0.001), resulting in device shortening. Multivariate analysis revealed that moderate and severe aortic valve calcification had 49% higher upward movement than mild calcification (p = 0.03), and aortic sinus volume was negatively correlated with movement size (r = -0.35, p = 0.005). This movement was independent of device version (SAPIEN vs. SAPIEN XT), procedural access (transfemoral vs. transapical), and interventricular septum width.
CONCLUSIONS: The final Edwards SAPIEN position is mostly aortic in relation to the lower sinus border. There is an operator-independent upward movement of the device center during the final stage of implantation. Anticipated upward movement of the device should influence its positioning before final deployment.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22625196     DOI: 10.1016/j.jcin.2012.03.005

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  12 in total

Review 1.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

2.  The impact of balloon-expandable transcatheter aortic valve replacement on concomitant mitral regurgitation: a comprehensive computational analysis.

Authors:  Andrés Caballero; Wenbin Mao; Raymond McKay; Wei Sun
Journal:  J R Soc Interface       Date:  2019-08-14       Impact factor: 4.118

Review 3.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

Review 4.  Transcatheter aortic valve implantation-induced left bundle branch block: causes and consequences.

Authors:  Thomas T Poels; Patrick Houthuizen; Leen A F M Van Garsse; Jos G Maessen; Peter de Jaegere; Frits W Prinzen
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

5.  Effect of Balloon-Expandable Transcatheter Aortic Valve Replacement Positioning: A Patient-Specific Numerical Model.

Authors:  Matteo Bianchi; Gil Marom; Ram P Ghosh; Harold A Fernandez; James R Taylor; Marvin J Slepian; Danny Bluestein
Journal:  Artif Organs       Date:  2016-12       Impact factor: 3.094

Review 6.  Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement.

Authors:  Rebecca T Hahn; Susheel Kodali; E Murat Tuzcu; Martin B Leon; Samir Kapadia; Deepika Gopal; Stamatios Lerakis; Brian R Lindman; Zuyue Wang; John Webb; Vinod H Thourani; Pamela S Douglas
Journal:  JACC Cardiovasc Imaging       Date:  2015-03

Review 7.  Clinical implications of conduction abnormalities and arrhythmias after transcatheter aortic valve implantation.

Authors:  Robert M A van der Boon; Patrick Houthuizen; Rutger-Jan Nuis; Nicolas M van Mieghem; Frits Prinzen; Peter P T de Jaegere
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 8.  Mechanisms and management of TAVR-related complications.

Authors:  Amir-Ali Fassa; Dominique Himbert; Alec Vahanian
Journal:  Nat Rev Cardiol       Date:  2013-10-08       Impact factor: 32.419

9.  Imaging in Transcatheter Aortic Valve Replacement (TAVR): role of the radiologist.

Authors:  Diana E Litmanovich; Eduard Ghersin; David A Burke; Jeffrey Popma; Maryam Shahrzad; Alexander A Bankier
Journal:  Insights Imaging       Date:  2014-01-21

10.  Transcatheter aortic valve replacement in membranous interventricular septum aneurysm with left ventricular outflow tract extension.

Authors:  Sandeep Banga; Marco A Barzallo; Casey L Nighswonger; Sudhir Mungee
Journal:  World J Cardiol       Date:  2018-01-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.