Literature DB >> 22624907

Objective comparison of 4 nonlongitudinal ultrasound modalities regarding efficiency and chatter.

David L DeMill1, Brian E Zaugg, Jeff H Pettey, Jason D Jensen, Griffin J Jardine, Gilbert Wong, Randall J Olson.   

Abstract

PURPOSE: To compare efficiency and chatter of Infiniti Ozil with and without Intelligent Phacoemulsification (IP) and the Signature Ellips with and without FX.
SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
DESIGN: Experimental study.
METHODS: Brunescent 2.0 mm human lens cubes were created by an instrument devised for this study. Cubes were tested (10 per test) for time of particle removal (efficiency) and for the number of times the lens particle bounced off the tip (chatter) at 300 mm Hg and 550 mm Hg, 50% and 100% power, and 50% and 100% amplitudes (amplitude for Ozil only).
RESULTS: Of the ultrasound settings, efficiency varied from a mean of 3.3 seconds ± 1.4 (SD) to 50.4 ± 11.7 seconds and chatter from 0.0 to 52.0 ± 16.7 bounces per run. The Ozil-IP was generally more efficient than the Ozil and the Ellips FX more efficient than the Ellips. At optimized values, the Ozil-IP and Ellips-FX were similar. In general, efficiency and chatter were better at 550 mm Hg and at 50% power. The amplitude effect was complex. Efficiency closely correlated with chatter (Pearson r(2) = .31, P<.0001).
CONCLUSIONS: Objective comparison of phacoemulsification efficiency and chatter found that optimized Ozil-IP and Ellips-FX were similar in both parameters and in general, both performed better than preceding technology. The study parameters can significantly affect efficiency and chatter, which strongly correlate with each other.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22624907     DOI: 10.1016/j.jcrs.2011.12.040

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  A novel method to compare phacoemulsification parameters in vivo: two halves of one nucleus.

Authors:  Elena Tomilova; Sergey Shukhaev
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-06-21       Impact factor: 3.117

2.  Measurement of Phacoemulsification Vacuum Pressure in the Oertli CataRhex3.

Authors:  John S Peterson; Caitlynn Cooper; Emilie L Ungricht; Christina Mamalis; William Barlow; Brian Zaugg; Ashlie A Bernhisel; Randall J Olson; Jeff H Pettey
Journal:  Clin Ophthalmol       Date:  2022-06-01

3.  Thermal imaging comparison of Signature, Infiniti, and Stellaris phacoemulsification systems.

Authors:  Na Kyung Ryoo; Ji-Won Kwon; Won Ryang Wee; Kevin M Miller; Young Keun Han
Journal:  BMC Ophthalmol       Date:  2013-10-12       Impact factor: 2.209

4.  Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve.

Authors:  Aeri Yoo; Ki Yeun Nam; Hungwon Tchah; Myoung Joon Kim
Journal:  PLoS One       Date:  2016-08-03       Impact factor: 3.240

5.  The effect of increasing power when grooving using phacoemulsification.

Authors:  Rhett S Thomson; Brian A Bird; Lance A Stutz; Joshua B Heczko; Ashlie A Bernhisel; William R Barlow; Brian Zaugg; Randall J Olson; Jeff H Pettey
Journal:  Clin Ophthalmol       Date:  2019-04-12

6.  Optimization of the Oertli CataRhex 3® phacoemulsification machine.

Authors:  Lance A Stutz; Joshua B Heczko; Brian A Bird; Rhett S Thomson; Ashlie A Bernhisel; William R Barlow; Brian Zaugg; Randall J Olson; Jeff H Pettey
Journal:  Clin Ophthalmol       Date:  2019-04-16

7.  Assessment of Learning Curve in Phacoemulsification Surgery Among the Eastern Province Ophthalmology Program Residents.

Authors:  Mohanna Al-Jindan; Abdullah Almarshood; Sanaa A Yassin; Khalid Alarfaj; Ammar Al Mahmood; Naif M Sulaimani
Journal:  Clin Ophthalmol       Date:  2020-01-14

8.  Optimizing Tip Diameter in Phacoemulsification of Varying Lens Sizes: An in vitro Study.

Authors:  Aniket Ramshekar; Joshua Heczko; Ashlie Bernhisel; William Barlow; Brian Zaugg; Randall Olson; Jeff Pettey
Journal:  Clin Ophthalmol       Date:  2021-11-17

9.  Optimization of Phacoemulsification Tip Gauge on the Oertli CataRhex3 in an in vitro Setting.

Authors:  John S Peterson; Michael R Christensen; Caitlynn Cooper; Christina Mamalis; Ashlie A Bernhisel; Brian Zaugg; William R Barlow; Emilie Ungricht; Randall J Olson; Jeff H Pettey
Journal:  Clin Ophthalmol       Date:  2022-04-08
  9 in total