Literature DB >> 22623109

Progressive structural and biomechanical changes in elastin degraded aorta.

Ming-Jay Chow1, Jarred R Mondonedo, Victor M Johnson, Yanhang Zhang.   

Abstract

Aortic aneurysm is an important clinical condition characterized by common structural changes such as the degradation of elastin, loss of smooth muscle cells, and increased deposition of fibrillary collagen. With the goal of investigating the relationship between the mechanical behavior and the structural/biochemical composition of an artery, this study used a simple chemical degradation model of aneurysm and investigated the progressive changes in mechanical properties. Porcine thoracic aortas were digested in a mild solution of purified elastase (5 U/mL) for 6, 12, 24, 48, and 96 h. Initial size measurements show that disruption of the elastin structure leads to increased artery dilation in the absence of periodic loading. The mechanical properties of the digested arteries, measured with a biaxial tensile testing device, progress through four distinct stages termed (1) initial-softening, (2) elastomer-like, (3) extensible-but-stiff, and (4) collagen-scaffold-like. While stages 1, 3, and 4 are expected as a result of elastin degradation, the S-shaped stress versus strain behavior of the aorta resulting from enzyme digestion has not been reported previously. Our results suggest that gradual changes in the structure of elastin in the artery can lead to a progression through different mechanical properties and thus reveal the potential existence of an important transition stage that could contribute to artery dilation during aneurysm formation.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22623109      PMCID: PMC3568224          DOI: 10.1007/s10237-012-0404-9

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  46 in total

1.  Differential effects of static and cyclic stretching during elastase digestion on the mechanical properties of extracellular matrices.

Authors:  Rajiv Jesudason; Lauren Black; Arnab Majumdar; Phillip Stone; Bela Suki
Journal:  J Appl Physiol (1985)       Date:  2007-05-31

2.  Elastase-induced saccular aneurysms in rabbits: a dose-escalation study.

Authors:  David F Kallmes; Naomi H Fujiwara; Stuart S Berr; Gregory A Helm; Harry J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2002-02       Impact factor: 3.825

3.  Linear and nonlinear viscoelastic modeling of aorta and carotid pressure-area dynamics under in vivo and ex vivo conditions.

Authors:  Daniela Valdez-Jasso; Daniel Bia; Yanina Zócalo; Ricardo L Armentano; Mansoor A Haider; Mette S Olufsen
Journal:  Ann Biomed Eng       Date:  2011-01-04       Impact factor: 3.934

4.  Elastin stabilization for treatment of abdominal aortic aneurysms.

Authors:  Jason C Isenburg; Dan T Simionescu; Barry C Starcher; Narendra R Vyavahare
Journal:  Circulation       Date:  2007-03-19       Impact factor: 29.690

5.  Elastase, collagenase, and the biaxial elastic properties of dog carotid artery.

Authors:  P B Dobrin; T R Canfield
Journal:  Am J Physiol       Date:  1984-07

6.  Biaxial tensile testing and constitutive modeling of human supraspinatus tendon.

Authors:  Spencer E Szczesny; John M Peloquin; Daniel H Cortes; Jennifer A Kadlowec; Louis J Soslowsky; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2012-02       Impact factor: 2.097

7.  A novel family of biodegradable poly(ester amide) elastomers.

Authors:  Hao Cheng; Paulina S Hill; Daniel J Siegwart; Nathaniel Vacanti; Abigail K R Lytton-Jean; Seung-Woo Cho; Anne Ye; Robert Langer; Daniel G Anderson
Journal:  Adv Mater       Date:  2011-03-10       Impact factor: 30.849

8.  A novel rat model of abdominal aortic aneurysm using a combination of intraluminal elastase infusion and extraluminal calcium chloride exposure.

Authors:  Akiko Tanaka; Tomomi Hasegawa; Zhi Chen; Yutaka Okita; Kenji Okada
Journal:  J Vasc Surg       Date:  2009-12       Impact factor: 4.268

9.  Influence of size, shape and properties on the mechanics of axisymmetric saccular aneurysms.

Authors:  S K Kyriacou; J D Humphrey
Journal:  J Biomech       Date:  1996-08       Impact factor: 2.712

10.  Altered structural and mechanical properties in decellularized rabbit carotid arteries.

Authors:  C Williams; J Liao; E M Joyce; B Wang; J B Leach; M S Sacks; J Y Wong
Journal:  Acta Biomater       Date:  2008-12-11       Impact factor: 8.947

View more
  22 in total

1.  Crosslinked elastic fibers are necessary for low energy loss in the ascending aorta.

Authors:  Jungsil Kim; Marius Catalin Staiculescu; Austin J Cocciolone; Hiromi Yanagisawa; Robert P Mecham; Jessica E Wagenseil
Journal:  J Biomech       Date:  2017-07-25       Impact factor: 2.712

2.  Mechanical Properties of Arterial Elastin With Water Loss.

Authors:  Yunjie Wang; Jacob Hahn; Yanhang Zhang
Journal:  J Biomech Eng       Date:  2018-04-01       Impact factor: 2.097

3.  Effect of glucose on the biomechanical function of arterial elastin.

Authors:  Yunjie Wang; Shahrokh Zeinali-Davarani; Elaine C Davis; Yanhang Zhang
Journal:  J Mech Behav Biomed Mater       Date:  2015-05-14

4.  Contribution of collagen fiber undulation to regional biomechanical properties along porcine thoracic aorta.

Authors:  Shahrokh Zeinali-Davarani; Yunjie Wang; Ming-Jay Chow; Raphaël Turcotte; Yanhang Zhang
Journal:  J Biomech Eng       Date:  2015-02-20       Impact factor: 2.097

5.  The inhibitor of semicarbazide-sensitive amine oxidase, PXS-4728A, ameliorates key features of chronic obstructive pulmonary disease in a mouse model.

Authors:  A G Jarnicki; H Schilter; G Liu; K Wheeldon; A-T Essilfie; J S Foot; T T Yow; W Jarolimek; P M Hansbro
Journal:  Br J Pharmacol       Date:  2016-10-12       Impact factor: 8.739

6.  Glycosaminoglycans contribute to extracellular matrix fiber recruitment and arterial wall mechanics.

Authors:  Jeffrey M Mattson; Raphaël Turcotte; Yanhang Zhang
Journal:  Biomech Model Mechanobiol       Date:  2016-08-04

7.  Arterial extracellular matrix: a mechanobiological study of the contributions and interactions of elastin and collagen.

Authors:  Ming-Jay Chow; Raphaël Turcotte; Charles P Lin; Yanhang Zhang
Journal:  Biophys J       Date:  2014-06-17       Impact factor: 4.033

8.  Artery buckling stimulates cell proliferation and NF-κB signaling.

Authors:  Yangming Xiao; Danika Hayman; Seyed Saeid Khalafvand; Merry L Lindsey; Hai-Chao Han
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-08-15       Impact factor: 4.733

9.  Characterization of biaxial mechanical behavior of porcine aorta under gradual elastin degradation.

Authors:  Shahrokh Zeinali-Davarani; Ming-Jay Chow; Raphaël Turcotte; Yanhang Zhang
Journal:  Ann Biomed Eng       Date:  2013-01-08       Impact factor: 3.934

10.  Mechanical, structural, and dynamical modifications of cholesterol exposed porcine aortic elastin.

Authors:  Kubra Bilici; Steven W Morgan; Moshe C Silverstein; Yunjie Wang; Hyung Jin Sun; Yanhang Zhang; Gregory S Boutis
Journal:  Biophys Chem       Date:  2016-09-09       Impact factor: 2.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.