Mechanical Properties of Arterial Elastin With Water Loss.

Yunjie Wang1, Jacob Hahn2, Yanhang Zhang2,3.   

Abstract

Elastin is a peculiar elastomer in that it requires water to maintain resilience, and its mechanical properties are closely associated with the immediate aqueous environment. The bulk, extra- and intrafibrillar water plays important roles in both elastic and viscoelastic properties of elastin. In this study, a two-stage liquid-vapor method was developed to investigate the effects of water loss on the mechanical properties of porcine aortic elastin. The tissue samples started in a phosphate-buffered saline (PBS) solution at their fully hydrated condition, with a gravimetric water content of 370±36%. The hydration level was reduced by enclosing the tissue in dialysis tubing and submerging it in polyethylene glycol (PEG) solution at concentrations of 10%, 20%, 30%, and 45% w/v, which reduced the water content of the samples to 258±34%, 224±20%, 109±9%, and 58±3%, respectively. The samples were then transferred to a humidity chamber to maintain the hydration level while the samples underwent equi-biaxial tensile and stress relaxation tests. The concentration of 10% PEG treatment induced insignificant changes in tissue dimensions and stiffness, indicating that the removal of bulk water has less effect on elastin. Significant increases in tangent modulus were observed after 20% and 30% PEG treatment due to the decreased presence of extrafibrillar water. Elastin treated with 45% PEG shows a very rigid behavior as most of the extrafibrillar water is eliminated. These results suggest that extrafibrillar water is crucial for elastin to maintain its elastic behavior. It was also observed that the anisotropy of elastin tends to decrease with water loss. An increase in stress relaxation was observed for elastin treated with 30% PEG, indicating a more viscous behavior of elastin when the amount of extrafibrillar water is significantly reduced. Results from this study shed light on the close association between the bulk, extra- and intrafibrillar water pools and the mechanics of elastin.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29305611      PMCID: PMC5816255          DOI: 10.1115/1.4038887

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  37 in total

1.  Effect of water on the molecular mobility of elastin.

Authors:  Valerie Samouillan; Cédric André; Jany Dandurand; Colette Lacabanne
Journal:  Biomacromolecules       Date:  2004 May-Jun       Impact factor: 6.988

2.  Dielectric response of deeply supercooled hydration water in the connective tissue proteins collagen and elastin.

Authors:  Catalin Gainaru; Ariane Fillmer; Roland Böhmer
Journal:  J Phys Chem B       Date:  2009-09-24       Impact factor: 2.991

3.  High resolution q-space imaging studies of water in elastin.

Authors:  Gregory Boutis; Christopher Renner; Tamara Isahkarov; Tasneem Islam; Lahiru Kannangara; Pavitarjit Kaur; Eugene Mananga; Atim Ntekim; Yisa Rumala; Doug Wei
Journal:  Biopolymers       Date:  2007 Dec 5-15       Impact factor: 2.505

4.  Biomechanical behavior of the arterial wall and its numerical characterization.

Authors:  G A Holzapfel; H W Weizsäcker
Journal:  Comput Biol Med       Date:  1998-07       Impact factor: 4.589

5.  The structures of elastins and their function.

Authors:  L Debelle; A J Alix
Journal:  Biochimie       Date:  1999-10       Impact factor: 4.079

6.  Tridimensional architecture of elastic tissue in the rat aorta and femoral artery--a scanning electron microscope study.

Authors:  K Wasano; T Yamamoto
Journal:  J Electron Microsc (Tokyo)       Date:  1983

7.  The temperature-dependent swelling of elastin.

Authors:  J M Gosline
Journal:  Biopolymers       Date:  1978-03       Impact factor: 2.505

8.  Dynamic mechanical properties of elastin.

Authors:  J M Gosline; C J French
Journal:  Biopolymers       Date:  1979-08       Impact factor: 2.505

9.  13C, 2h NMR studies of structural and dynamical modifications of glucose-exposed porcine aortic elastin.

Authors:  Moshe C Silverstein; Kübra Bilici; Steven W Morgan; Yunjie Wang; Yanhang Zhang; Gregory S Boutis
Journal:  Biophys J       Date:  2015-04-07       Impact factor: 4.033

10.  Effect of altered hydration on the internal shear properties of porcine aortic valve cusps.

Authors:  E A Talman; D R Boughner
Journal:  Ann Thorac Surg       Date:  2001-05       Impact factor: 4.330

View more
  5 in total

1.  Effect of Glycation on Interlamellar Bonding of Arterial Elastin.

Authors:  R Wang; X Yu; A Gkousioudi; Y Zhang
Journal:  Exp Mech       Date:  2020-07-29       Impact factor: 2.808

2.  Effect of different preconditioning protocols on the viscoelastic inflation response of the posterior sclera.

Authors:  Gianfranco Bianco; Alexander M Levy; Rafael Grytz; Massimo A Fazio
Journal:  Acta Biomater       Date:  2021-04-29       Impact factor: 10.633

Review 3.  The "Elastic Perspective" of SARS-CoV-2 Infection and the Role of Intrinsic and Extrinsic Factors.

Authors:  Federica Boraldi; Francesco Demetrio Lofaro; Andrea Cossarizza; Daniela Quaglino
Journal:  Int J Mol Sci       Date:  2022-01-29       Impact factor: 5.923

4.  Biomimetic Remineralization of an Extracellular Matrix Collagen Membrane for Bone Regeneration.

Authors:  Raquel Osorio; Samara Asady; Manuel Toledano-Osorio; Manuel Toledano; Juan M Bueno; Rosa M Martínez-Ojeda; Estrella Osorio
Journal:  Polymers (Basel)       Date:  2022-08-11       Impact factor: 4.967

5.  What is Considered a Variation of Biomechanical Parameters in Tensile Tests of Collagen-Rich Human Soft Tissues? - Critical Considerations Using the Human Cranial Dura Mater as a Representative Morpho-Mechanic Model.

Authors:  Johann Zwirner; Mario Scholze; Benjamin Ondruschka; Niels Hammer
Journal:  Medicina (Kaunas)       Date:  2020-10-05       Impact factor: 2.430

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.