Literature DB >> 22619896

Reliability of visual acuity measurements taken with a notebook and a tablet computer in participants who were illiterate to Roman characters.

Paisan Ruamviboonsuk1, Napitchareeya Sudsakorn, Thanapong Somkijrungroj, Chayanee Engkagul, Montip Tiensuwan.   

Abstract

BACKGROUND: Electronic measurement of visual acuity (VA) has been proposed and adopted as a method of determining VA scores in clinical research. Characters (optotypes) are displayed on a monitor screen and the examinee selects a match and inputs his choice to another electronic device. Unfortunately, the optotypes, called Sloan letters, in the standard protocol are 10 Roman characters. This limits their practicabilityfor measuring VA of patients who are illiterate to these characters. The authors introduced a method of displaying the Sloan letters one by one on a notebook and all 10 Sloan letters on a tablet computer screen. The former is for testing the patients whereas the latter is for them to input their responses by tapping on a letter that matches the one on the notebook screen.
OBJECTIVE: To assess test-retest reliability of VA scores determined with this method. MATERIAL AND
METHOD: Participants without ocular abnormality were recruited to have their right eyes measured with the same VA measurement method twice, one week apart. Those who were illiterate to Roman characters were enrolled for the aforementioned method for measuring their VA (Tablet group). A 15-inch display notebook computer and a 9-inch display tablet computer (iPad) communicated via a local wireless data network provided by a Wi-Fi router. Those who understood Roman characters were enrolled to have measurements with a 17-inch desktop computer and an infrared wireless keyboard (Keyboard group). Both methods used the same protocols and software for VA measurements. Reliability of VA scores obtained from each group was assessed by the confidence interval (CI) of the difference of the scores from the test and retest. The t test was used to analyze differences in mean VA scores between the test and retest in each group with p < 0.05 determined as statistically significant.
RESULTS: There were 49 and 50 participants in the Tablet and Keyboard group respectively. The 95% CI of the difference between the scores from the test and retest in each group was 2 letters. Approximately 95% of participants in each group had an absolute difference of the scores between the test and retest of 7 letters. The mean of VA scores from the first test was significantly different from that of the second test in the Keyboard group (one-letter difference, p = 0.049); there was no significant difference between these scores in the Tablet group (0.1-letter difference, p = 0.86).
CONCLUSION: Tablet computers may be used to assist patients who are illiterate to Roman characters in having their VA measured with the standard electronic protocol. This preliminary study suggested that the proposed method should be useful for reliable measuring VA outcome in multicenter international clinical trials without encountering a language barrier

Entities:  

Mesh:

Year:  2012        PMID: 22619896

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  2 in total

1.  Development and testing of an automated computer tablet-based method for self-testing of high and low contrast near visual acuity in ophthalmic patients.

Authors:  Tariq M Aslam; Neil R A Parry; Ian J Murray; Mahani Salleh; Caterina Dal Col; Naznin Mirza; Gabriela Czanner; Humza J Tahir
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-22       Impact factor: 3.117

2.  Photometric Compliance of Tablet Screens and Retro-Illuminated Acuity Charts As Visual Acuity Measurement Devices.

Authors:  I A T Livingstone; C M Tarbert; M E Giardini; A Bastawrous; D Middleton; R Hamilton
Journal:  PLoS One       Date:  2016-03-22       Impact factor: 3.240

  2 in total