Comparisons between surface electrodes and intramuscular wire electrodes in isometric and dynamic conditions.

B Giroux1, M Lamontagne.   

Abstract

The purpose of this study was to compare EMG surface electrodes (SE) and intramuscular wire electrodes (IWE) for isometric and dynamic contractions during an occupational cervico-brachial working task (OCWT). Six normal adult male subjects were tested on two days (two conditions with three trials each). Raw EMG signals from middle deltoid, anterior deltoid and trapezius muscles were recorded by both IWE and SE for two conditions (isometric and dynamic contractions). Full wave rectified and low pass filtered EMG, and integrated EMG were processed from raw EMG signals. The statistical analysis performed on the integrated EMG was a factorial analysis model with repeated measures. Statistical results confirmed that EMG signals, from both SE and IWE, are reliable between trials on the same day. These statistical results also confirmed that SE are more reliable than IWE on day-to-day investigations. Both electrodes recorded statistically similar signals, although the coefficient of variability between electrodes was very high (STDE%; 48% and 84%, for isometric and dynamic conditions respectively).

Mesh:

Year:  1990        PMID: 2261884

Source DB:  PubMed          Journal:  Electromyogr Clin Neurophysiol        ISSN: 0301-150X


  8 in total

1.  A spectral analysis of rotator cuff musculature electromyographic activity: surface and indwelling.

Authors:  Sherry I Backus; Daniel P Tomlinson; Bavornrat Vanadurongwan; Mark W Lenhoff; Frank A Cordasco; Eric L Chehab; Ronald S Adler; R Frank Henn; Howard J Hillstrom
Journal:  HSS J       Date:  2010-08-13

2.  Sensorimotor system measurement techniques.

Authors:  Bryan L Riemann; Joseph B Myers; Scott M Lephart
Journal:  J Athl Train       Date:  2002-01       Impact factor: 2.860

3.  Extramuscular Recording of Spontaneous EMG Activity and Transcranial Electrical Elicited Motor Potentials in Horses: Characteristics of Different Subcutaneous and Surface Electrode Types and Practical Guidelines.

Authors:  Sanne Lotte Journée; Henricus Louis Journée; Stephen Michael Reed; Hanneke Irene Berends; Cornelis Marinus de Bruijn; Cathérine John Ghislaine Delesalle
Journal:  Front Neurosci       Date:  2020-07-17       Impact factor: 4.677

4.  A comparison of the effects of electrode implantation and targeting on pattern classification accuracy for prosthesis control.

Authors:  Todd R Farrell; Richard F Ff Weir
Journal:  IEEE Trans Biomed Eng       Date:  2008-09       Impact factor: 4.538

5.  Surface electrodes are not appropriate to record selective myoelectric activity of splenius capitis muscle in humans.

Authors:  M A Benhamou; M Revel; C Vallee
Journal:  Exp Brain Res       Date:  1995       Impact factor: 1.972

6.  A reliability of electromyographic normalization methods for the infraspinatus muscle in healthy subjects.

Authors:  Sung-Min Ha; Heon-Seock Cynn; Oh-Yun Kwon; Kyue-Nam Park; Gyoung-Mo Kim
Journal:  J Hum Kinet       Date:  2013-03-28       Impact factor: 2.193

Review 7.  Surface electromyography as a screening method for evaluation of dysphagia and odynophagia.

Authors:  Michael Vaiman; Ephraim Eviatar
Journal:  Head Face Med       Date:  2009-02-20       Impact factor: 2.151

8.  Activity Evaluation of Facial Muscles by Surface Electromyography.

Authors:  Nicolò Bertozzi; Bernardo Bianchi; Luana Salvagni; Edoardo Raposio
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-10-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.